7.6 Change air and fluid nozzles
Remove nozzles
1.
Chapter 6.5 ‘Shutting down’ on page 24
2.
If necessary, secure pump or pressure container for the fluid against restart.
Fig. 9: Remove nozzles
3.
Loosen the knurled nut ( Fig. 91).
4.
Remove the air nozzle ( Fig. 9/2).
5.
Activate and hold the pull lever ( Fig. 9/5).
6.
Unscrew the fluid nozzle ( Fig. 9/3) with a respective fork wrench.
Always change the fluid nozzle ( Fig. 9/3) and fluid needle ( Fig. 9/4) at the same time.
Attach nozzles
1.
Activate and hold the pull lever ( Fig. 9/5).
2.
Tighten the fluid nozzle ( Fig. 9/3) with suitable fork wrench.
3.
Release the pull lever ( Fig. 9/5).
4.
Attach the air nozzle ( Fig. 9/2) and tighten it with the knurl nut ( Fig. 9/1).