7.5
Changing needle packing
Removing needle packing
1.
Chapter 7.2 ‘Cleaning spray guns’ on page 24
2.
Remove the fluid needle (
Chapter 7.4 ‘Changing the fluid needle’ on page 26
)
Fig. 15: Removing needle packing
3.
Unscrew the screw (Fig. 15/2) from the head section (Fig. 15/1) and the main element
(Fig. 153).
4.
Remove the head section (Fig. 15/1) from the main element (Fig. 15/3).
Fig. 16: Removing needle packing
5.
Unscrew the seal screw (Fig. 16/3).
6.
Remove all of the needle packing (Fig. 16/4) from the head section (Fig. 16/5).
7.
Remove the seals (Fig. 16/2) from the centring tubes (Fig. 16/1).
Operating instructions
T-Dok-040-GB-Rev.1
[email protected], www.krautzberger.com
GB–28