7  Wearing parts, spare parts 

Gaskets are subject to material fatigue and natural wear. Defective gaskets are noticeable from 
the leakage of air or coating substance on fittings or connections. Gaskets may be made of 
NBR, PE, EPDM or Viton. 

When changing gaskets, check compatibility with the coating substance used. 

Cover gasket for 50-litre and 100-litre container 

Material Article 

number 

NBR 5840-010-0220 

PE 5840-010-0221 

EPDM 5840-010-0222 

Viton 5840-010-0223 

 

8 Troubleshooting 

Problem Cause  Remedy 

Leakage between container 
flange and cover 

Container flange, cover gas-
ket soiled or porous 

Clean or replace 

Leakage at compressed air fit-
ting 

Gaskets defective 

Replace gaskets 

Leakage at stirrer mounting 

Gasket defective 

Replace gaskets 

Leakage at material outlet 

Gasket defective 

Replace gaskets 

Material pressure cannot be ad-
justed 

Material pressure regulator 
defective 

Replace 

 

9 Technical data 

 

50-litre type 

100-litre type 

Compressed air feed 

dry, oil-free, filtered

2.5-6bar

dry, oil-free, filtered 

2.5-6bar

Max. filling volume 

5

8

 litres

1

26

 litres

Ambient temperature 

-10 to +50°C

-10 to +50°C

Temperature – coating material 

-10 to +50°C

-10 to +50°C

Test pressure/Date 

3.6bar/8.6bar

3.6bar/8.6bar

Setting pressure of over- 
pressure valve 

customer-specific

customer-specific

Weight (empty) 

63-72kg

88-97kg

Dimensions 

max. 1025x495mm

max. 1300x625mm

Mains voltage – electric stirrer 

230V/50Hz

230V/50Hz

 

 

 

Summary of Contents for 200-0157

Page 1: ...Operating instructions Pressure container 50 litre capacity for operating pressures of 2 5 and 6 bar Doc 315 Rev 0...

Page 2: ...stir rers level gauges filling devices and other accessories Krautzberger 50 litre and 100 litre pressure containers are designed for 10 000 stress reversals 1 stress reversal or load cycle is equival...

Page 3: ...rking zone Do not use halogenated detergents Chemical reactions may cause explo sive and caustic compounds Electrostatic charges during opera tion of the pressure container can lead to electric shocks...

Page 4: ...ional 8 Ball cock for venting 9 Material return optional 10 Sound dampener or connection option for waste air line 11 Safety valve The material extraction point 4 can be located the bottom or routed t...

Page 5: ...y must be dry and oil free Make the necessary provision for a suitable shutoff device ball cock The compressed air fitting can be equipped with more than one if necessary adjustable outlet for the con...

Page 6: ...fore you begin operating the system Before opening the pressure container check the cover gasket for soiling wear and damage Before opening a pressure container for all maintenance servicing and clean...

Page 7: ...over gas ket soiled or porous Clean or replace Leakage at compressed air fit ting Gaskets defective Replace gaskets Leakage at stirrer mounting Gasket defective Replace gaskets Leakage at material out...

Page 8: ...Designation MDH Type 50l Dokumentation DOK 315 GB doc Order No 200 0157 10 Dimensions Je nach R hrwerk 760 310 470 550 390 765 650 8...

Page 9: ...LEMENTATION EG Druckger terichtlinie 97 23 EWG EG Niederspannungs Richtlinie 73 23 EWG nur bei elektri schen Anbauteilen EG EMV Richtlinie 93 68 EWG nur bei elektrischen Anbauteilen EG Maschinenrichtl...

Page 10: ...bstances used and the outcome of previous inspections However the following periods may not be exceeded Internal inspection every 5 years Pressure testing every 10 years External inspection every 2 ye...

Page 11: ...Designation MDH Type 50l Dokumentation DOK 315 GB doc Order No 200 0157 11 first periodic inspection next periodic inspection Installation test...

Page 12: ...Designation MDH Type 50l Dokumentation DOK 315 GB doc Order No 200 0157 next periodic inspection next periodic inspection 12...

Page 13: ...Designation MDH Type 50l Dokumentation DOK 315 GB doc Order No 200 0157 next periodic inspection next periodic inspection 13...

Page 14: ...Designation MDH Type 50l Dokumentation DOK 315 GB doc Order No 200 0157 next periodic inspection next periodic inspection 14...

Page 15: ...Designation MDH Type 50l Dokumentation DOK 315 GB doc Order No 200 0157 next periodic inspection next periodic inspection 15...

Reviews: