3
Preparation for use
Stationary cold water high pressure cleaner:
The stationary wall-mounted systems are supplied with a stainless steel housing.
Equipped with an AQ pump, 10m steel fabric heavy duty hose, pressure fully ad-
justable, automatic total-stop feature and adjustable after-running. 1-5 bar ad-
vance pressure required (not self-intake).
The control is switched via a flow detector and controlled via a time relay. After
the gun is closed, the device continues to run for a time and then cuts out. It re-
starts when the gun is opened. Incorrect operation by unauthorised persons is
therefore not possible. Time setting of 1 to 180 seconds is possible. The factory
setting is 30 seconds. The device is connected to a water supply with advance
pressure. Temperatures of up to 70 °C are possible.
Features
Stainless steel housing,
10 m heavy duty hose with gun
Lance 800 mm
Control nozzle and HD nozzle.
Start-up
Open the water tap.
Set the black turn-knob to 1, and the device is in WAIT mode.
The high pressure pump starts if you then press the gun.
After closing the gun, it continues to run for approx. 30 seconds, and then
switches back to WAIT mode.
The device continues to run if the gun is pressed during the 30 seconds.
Green lamp: device in operation
Red lamp : malfunction
Summary of Contents for W 11/135
Page 12: ...12 Valve housing ...
Page 14: ...14 Motor ...
Page 16: ...16 Drive unit AQ ...
Page 18: ...18 Power Colt ...
Page 20: ...20 ULH 250 ...
Page 22: ...22 Control unit 1 2 12 11 3 4 5 6 7 10 9 8 ...
Page 32: ...Reprint only allowed with the authorization of As of date of 13 09 1999 Ord No 30 242 1 ...