ENGLISH
- 6
Professional Cleaning Machines Since 1968
ENGLISH
- 7
PREPARING
THE APPLIANCE
- Remove the plug (1 Fig. 1) fpr the evacu-
ationpump.
- Release the levers (2 Fig. 2) and remove
the cover (3 Fig. 3) complete with the mo-
tor unit.
- Verify that there is the filter bag (4 Fig. 4)
in the tank and the filter in Nylon (31, Fig.
3).
- If the filter bag (4 Fig. 4) is not present,
install it as follows:
Slide the plastic ring (5 Fig. 5) of the bag
into the orifice (6 Fig. 5) until you hear the
click of the lock ring in the groove (7 Fig.
5).
- Place the cover back on and lock it using
the levers (2 Fig. 2).
- Insert the plug (1 Fig. 1) int the socket.
- Insert, as far as possible, the sleeve (8
Fig. 6) of the suction hose into the nozzle
(9 Fig. 6) on the drum.
- To release the sleeve (8 Fig. 6) turn the
lever (10 Fig. 6) clockwise and then pull
the sleeve outwards (8 Fig. 6).
- Join the hose (11 Fig. 7) with the exten-
sion (12 Fig. 7).
- Connect the two rigid extensions (12-
13 Fig. 8) by aligning the two reference
points (14-15 Fig. 8).
- Mount on the rigid extension (13 Fig. 9)
the desired accessory,( vacuum nozzle,
floor nozzle etc..).
- Connect a hose to the exhaust outlet of
1/4 “(14 Fig. 10).
USING THE APPLICANCE
- The unit is equipped with wheels and can
be pushed with the handle (15 Fig. 11).
- Its lifting should be done by two people
using the handles (16 Fig. 11).
Starting up the appliance
- Insert the plug (17 Fig. 12) in the socket
and check that the plug (1 Fig. 1) is cor-
rectly inserted.
- Depending on the power required it is
possible to start only one motor by press-
ing the switch (18 Fig. 13) on “I” or both
switches (18-19 Fig. 13) if a greater suc-
tion force is required.
When the switch pressed the correspond-
ing button lights up.
- To start the pump, press the button (20
Fig. 13) after checking that the drain
valve (21 Fig. 14) is open.
NOTES:
The operation of the pump is controlled by a
start float positioned inside the tank; to en-
sure the correct operation and the correct
cooling of the same, the pump starts when
inside the reservoir the level of the water
reaches 1 cm in height and stops when the
level drops below this height.
NOTES:
In case the recovery tank fills up, there is an
increase of noise and the device no longer
vacuums, then turn off the appliance and
empty the tank.
Switching off the appliance
- Push the switches (18-19-20 Fig. 13) to
the “0” position to stop the device; the
lights, if any on the switches, will go off.
- Remove the plug (17 Fig. 12) from the
electrical socket.
- Wind up the cable (23 Fig. 16) and hook
it onto its housing (24 Fig. 16).
CLEANING AND
MAINTENANCE
DANGER:
Before performing any maintenance
operation, unplug the appliance from the
electrical socket.
Daily cleaning
Check and clean network filter
- Remove the cylinder head as described
above.
- Remove the network filter (4 Fig. 4).
- Open the filter (4 Fig. 15) using the clip
(22 Fig. 15), rinse and drain it from any
solid residue and then close the clip (22
Fig. 15) and reassemble as described
above.
- Reassemble all the parts by following the
dismantling process steps in the reverse
order.
Cleaning the appliance
- Clean the unit body with a cloth damp-
ened with water or a mild detergent.
- Remove the cylinder head as previously
indicated and clean the inside of the tank
from the residues of dirt with running
water, as they can interfere with the op-
eration, and then drain it, by starting the
evacuation pump in order to clean both
the pump and the discharge pipe.
Replace everything doing the opposite of
the disassembly.
NOTES:
Clean the start float (25 Fig. 17) checking
that it slides without difficulty.
DANGER:
Do not wash the appliance using jets of
water.