Kranzle therm 1165-1 Operating Manual Download Page 24

46

47

Water supply

High-pressure pump

Problem Possible cause

Float valve is dirty/defect
Float valve is defect, water inlet filter dirty, 

water intake too low 
Valves sticky or are dirty, suction hose leaks, 

detergent valve is open or leaks, Check hose  

connections, high-pressure nozzle is clogged
Connect water inlet directly to the 

high-pressure pump (2-8 bar pre-pressure).  

Disconnect suction lines below the 

high-pressure pump.

Water tank runs over

Water tank does not fill completely

High-pressure pump does not suck

Test: Check water and additive 

suction system for tightness

High-pressure pump sucks air, check sucti-

on connections and high-pressure nozzle, 

check O-rings and valves, check sleeves. 

Unloader: Check stainless steel seat and 

ball. Check seals on the control piston.
Replace sleeves in the high-pressure pump. 

Replace O-rings
High-pressure nozzle washed out, stainless 

steel seat, ball, O-ring in unloader is dirty  

or defect.

High-pressure pump makes lots 

of noise. Operating pressure is not 

reached

Water drops from the  

high-pressure pump

Pressure is too low

Summary of additional causes of malfunction

Check/replace oil seals.

Check plunger and plunger guides.

Oil drops from the transmission

High-pressure cleaner start/stop

Check return body and O-ring in  

unloader of the valve housing.
Check pressure switch, check micro switch, 

check cable connections. 
Check electricity supply, check main switch, 

check cable connections, board is defect. 

Switch off by overcurrent release. 

Check micro switch. 
Check electricity supply, check main switch, 

check cable connections. Switch off by over-

current release. Check micro switch.

High-pressure cleaner  

does not switch off

Test: Jumper pressure switch 

High-pressure cleaner does not 

start or stopps during operation 

High-pressure cleaner does not

Leckage 

Gun defective. Let repair.

Replace seals. Replace O-ring under  

screwed connection. 
Clean high-pressure nozzle

Trigger gun with safety catch drips

High-pressure hose drips

Stainless steel pressure gauge shows  

pressure but no water comes out

Sucking detergent

High-pressure pump sucks air. 

Check hose clips.

Test: Connect water line to the high- 

pressure pump. No water must come  

from the detergent hose

Detergent is not sucked

In case of repeated mulfunction or should you be incapable of resolving 

it by yourself, please contact our customer service.

Pull plug from socket prior to starting any repair work!

Small repairs - do it yourself

Small repairs - do it yourself

Summary of Contents for therm 1165-1

Page 1: ...www kraenzle com Cold and hot water high pressure cleaner therm 635 1 therm 875 1 therm 895 1 therm 1165 1 Operating manual EN...

Page 2: ...1165 1 Operating manual This manual is a translation of the original manual Read and conform safety instructions before use Technical data will be found in the Spare parts list Please be aware that th...

Page 3: ...not be disposed of as household waste Information on proper disposal will be gathered from the recycling directives issued by your local authority Dear customer we would like to congratulate you on th...

Page 4: ...ty instructions be observed Step 3 Connect to circuit see technical data Step 4 Usage as a cold water high pressure cleaner Switch on high pressure cleaner at main switch with opened safety trigger gu...

Page 5: ...nerated An aerosol is a mixture of floating solid or liquid particles in a gas Inhaling aerosol parti cles may cause damage to health Employers are under obligation to carry out a hazards assessment i...

Page 6: ...sure jet at people or animals Never direct the high pressure jet at yourself or other persons not even to clean clothing or shoes Never direct the high pressure jet at the high pressure cleaner itself...

Page 7: ...n 8 Feed line water inlet water hose connection 9 Water inlet filter 10 Storage bin for accessories 11 Integrated trolley takes rough ground in its stride 12 Locking brake 13 Large removable caps see...

Page 8: ...r inlet water hose connection 9 Water inlet filter 10 Storage bin for accessories 11 Integrated trolley takes rough ground in its stride 12 Locking brake 13 Large removable caps see page 17 14 Filler...

Page 9: ...series are cold and hot water high pressure cleaners They offer many functions and electronics inside the high pressure cleaners Please see construction scheme for more details 7 Fan with fuel pump 8...

Page 10: ...ing brush Environmental refuse disposal and water protection regulations must be observed Inspections The high pressure cleaner was finally inspected by the company Kr nzle refer to Kr nzle final repo...

Page 11: ...safety catch recognizable by whitish colour 7 Switch high pressure cleaner at the main switch on OFF and let descaling agent work for 15 20 minutes 8 Switch high pressure cleaner at the main switch o...

Page 12: ...me 27 hours and 18 minutes The thermostat has two operating modes 1 Temperature mode This mode is always activated when the unit is switched on or can be selected using the C button Pos 5 The red LED...

Page 13: ...do it yourself in these operating manuel Heat exchanger The water is forced through a heating coil by the high pressure pump The fuel pump sucks the fuel oil from the fuel tank via a fuel filter an a...

Page 14: ...ailable quantity of water by fil ling a bucket with liter scale for one minute Required minimum quantity of water see technical data If the metered quantity of water is too small you have to use a dif...

Page 15: ...ed on again by the main switch The machine restarts automatically when the gun is re opened provided that the master switch is on Water and cleaning system Water can be connected at mains pressure to...

Page 16: ...y or twisted The high pressure hose may under no circumstances be pulled over sharp edges Defective high pressure hoses must not be repaired acc to DIN 20022 but have to be replaced by new hoses appro...

Page 17: ...thout nooses The high pressure hose may leave signs of abrasion on some floors Alternatively please also find non marking high pressure hoses in our range 7 Tightly screw together high pressure hose a...

Page 18: ...urbokiller available optionally ensure that the lance is pointing down for start up Prior to putting the high pressure cleaner into operation make sure that all safety instructions be observed Usage a...

Page 19: ...his case the water tank must be bypassed Prior to starting the first suction the high pressure pump and the suction hose has to be filled with water Note Depending on the water quality it may occur af...

Page 20: ...igh pressure cleaner Wait with opened gun until the agent spurts out of the nozzle Suction of additives Due to the water tank fitted to the therm 1 series it is now possible to directly suck the deter...

Page 21: ...by a qualified organisation or person according to German law The first inspection must be carried out four weeks after the machine is commissioned The owner is responsible for having the inspection p...

Page 22: ...ss steel pressure gauge shows full pressure Cause Most likely the nozzle is blocked Pull plug from socket prior to starting any repair work Small repairs do it yourself Small repairs do it yourself Th...

Page 23: ...so the connection between lance and safety trigger gun for tightness Switch off the cleaner Shortly press the trigger of the trigger gun with safety catch to decrease the pressure Remove high pres sur...

Page 24: ...l seals Check plunger and plunger guides Oil drops from the transmission High pressure cleaner start stop Check return body and O ring in unloader of the valve housing Check pressure switch check micr...

Page 25: ...ance without heating Heating OFF until the temperature has dropped below 147 C Switch main switch OFF and then back ON again Err E2 Temperature sensor defective Replace temperature sensor Err E5 Flow...

Page 26: ...1 410723 therm 1165 1 410727 Floor washer Round Cleaner UFO lang stainless steel From stainless steel 350 mm Nozzle system 045 Item no 41861 Not suitable for therm 1165 1 Oder item no 41106 for the th...

Page 27: ...pressure cleaner and intensity of its use are defined as normal wear in respect of product components Purchaser s rights to assert claims for such defects are ruled out Parts subject to wear include i...

Page 28: ...nction Flow controller function Power supply cable damage Power plug damage Protective conductor connected On Off switch Water quantity safety device function Used chemicals Allowed chemicals The next...

Page 29: ...e Result of flue gas analysis Inspector Date Signature Steam phase checked Detergent valve checked Start Stop automatic and re run delay checked Fuel shortage switch checked Thermostat function checke...

Page 30: ...58 59 Notes Notes...

Page 31: ...kraenzle com Made in Germany Kr nzle 17 01 2020 Ord no 307680 Subject to technical modifications and errors Josef Kr nzle GmbH Co KG Rudolf Diesel Stra e 20 89257 Illertissen Germany sales kraenzle c...

Reviews: