34
35
Putting into operation
Putting into operation
12.
For getting access to the interior fitting
of the high-pressure cleaner, loosen
screws at the cover. Remove cap
carefully.
Close cap properly prior to starting
the washing procedure.
13. Each time check oil level at the oil dip-
stick prior to putting the high-pressure
cleaner into operation.
Oil level must
reach until the upper edge of marking
"OK“. See chapter „Care and Main-
tenance“ in these operating manual.
14.
Connect to circuit (see technical data).
Do not touch the mains plug or any live parts with wet or moist hands.
15.
When using the turbokiller (available
optionally), ensure that the lance is
pointing down for start-up.
Prior to putting the high-pressure cleaner into operation make sure
that all safety instructions be observed.
Usage as a cold water high-pressure cleaner
1.
Detergent valve must be closed.
2.
Switch on high-pressure cleaner with
opened trigger gun (trigger pulled).
Bleeding of the high-pressure cleaner:
Pull and release trigger of trigger gun
with safety catch several times.
Start with cleaning process.
3.
When starting the cleaning process
do
not
aim the water jet towards the
object you want to clean for at least
30 seconds. Maybe the water inside
the combustion chamber has changed
colour due to the rest time.
16.
Adjust operating pressureinfinitely
using the rotary handle. The maximum
pressure is factory-set.
Summary of Contents for therm 1165-1