VS-801USB - Default Communication Parameters
13
13
8
Default Communication Parameters
RS-232
Protocol
3000 (Default)
2000
Baud Rate:
115,200
9,600
Data Bits:
8
8
Stop Bits:
1
1
Parity:
None
None
Command Format:
ASCII
ASCII
Example (Input 1 to Output 1):
#AV 1>1<CR>
0x01, 0x81, 0x81, 0x81
Switching Protocol
P2000 -> P3000
P3000 -> P2000
Command: 0x38, 0x80, 0x83, 0x81
Command:
#P2000<CR>
Front Panel: Press and hold DEVICE
SELECT buttons 1 and 3
simultaneously
Front Panel:
Press and hold DEVICE
SELECT buttons 1 and 2
simultaneously
Ethernet
IP Address:
192.168.1.39
Subnet mask:
255.255.255.0
Default gateway:
192.168.1.1
TCP Port #:
5000
UDP Port #:
50000
Maximum UDP Ports: 10
Maximum TCP Ports:
4
Factory Reset
RESET button
To reset the IP settings to the factory reset values, power cycle the device
while holding in the RESET button, located on the rear panel of the unit
Protocol 3000
Use “Factory” command or #Y 0,760,1<CR>