10
VS-801USB - Operating the VS-801USB
5
Operating the VS-801USB
You can operate the
VS-801USB
via the front panel buttons (see
Section 5.1
), the
REMOTE contact closure terminal block connectors (see
Section 5.2
), the
application software (see
Section 5.3
) or the
RC-IR3
IR remote control transmitter.
5.1
The Front Panel Buttons
To select a DEVICE to switch to the HOST, press one of the eight DEVICE
SELECT buttons.
5.2
The REMOTE Terminal Block Connector
The contact closure remote control pins operate in a similar way to the INPUT
SELECT button. Using the contact closure remote control (also known as push-to-
make momentary contact) you can select the desired USB port. To do so,
momentarily connect the required DEVICE pin (from 1 to 8) on the REMOTE
terminal block connector to the G (Ground) pin, as
Figure 5
illustrates.
!
Do not
connect more than one PIN to the GND PIN at the same time.
Figure 5: Connecting the Contact Closure Remote Control PINs
5.3
The Application Software
Use the K-SINGLE control application software to control the
VS-801USB
via the
Ethernet or RS-232 9-pin D-sub.
i
The latest version of K-SINGLE and installation instructions can be
downloaded from the Kramer Web site at
www.kramerelectronics.com