background image

KRAMER:  SIMPLE CREATIVE TECHNOLOGY

 

Operating Your Video Matrix Switcher 

 

32 

10.3  Toggling Between the AT ONCE and CONFIRM Modes 

To toggle between the AT ONCE (default) mode and the CONFIRM mode, 
press the TAKE button. 

In CONFIRM mode: Actions require user confirmation and the TAKE LED 
lights. 

In AT ONCE mode: Actions do not require user confirmation and the 
TAKE LED does not light. 

When the TAKE LED flashes: 

 

You cannot toggle between the AT ONCE and CONFIRM modes 

 

You can execute the previous action, by pressing the TAKE 
button 

 

You can cancel the previous action, by pressing a non-relevant 
button (for example, the MENU button) 

10.4  Switching 

You can switch: 

 

One input to one output (see section 

 10.4.1

 

Several inputs to several outputs (see section 

 10.4.2

 

One input to all outputs (see section 

 10.4.3

10.4.1 Switching One Input to One Output 

Pressing an

 

OUT-IN combination when your 

VS-162V

 operates in the AT 

ONCE mode implements the switch immediately. 

To switch one input to one output (AT ONCE mode): 

1.  Press the appropriate OUT button. 

The MATRIX display shows the two flashing digits, representing the 
present input number connected to that specific output

1

out # x 

. If the present 

output is clear, the two flashing digits 

00

 appear in the MATRIX display. 

The STATUS Display shows the message: 

Where x is the output number 

2.  Press the appropriate IN button. 

The output switches to the input and the MATRIX display shows the Input 
# instead of the flashing digits. 
The STATUS Display momentarily shows the message: 

                                                        

1 For example, pressing OUT button 9 shows the flashing digits 01 if input 1 was previously routed to OUT 9 

Summary of Contents for VS-162V

Page 1: ...Kramer Electronics Ltd USER MANUAL Model VS 162V 16x16 Video Matrix Switcher ...

Page 2: ...atrix Switcher 15 7 3 1 Configuring a 32x16 Switcher 16 7 3 2 Configuring a 32x32 Switcher 17 7 4 Configuring a System of Interconnected Switchers 18 8 Understanding Addressing and System Modes 20 8 1 Setting the DIP Switches 20 8 2 Setting the MACHINE 21 8 3 Setting the MACHINE ADDRESS 21 8 4 Understanding the SYSTEM Mode 21 8 5 Understanding the SLAVE Mode 22 9 Connecting a Control Interface 22 ...

Page 3: ...ing the Video Format Setting 43 11 4 Setting the MACHINE ADDRESS 44 11 4 1 Changing the Standalone MACHINE ADDRESS to a Large Matrix 45 11 4 2 Changing the Large Matrix MACHINE ADDRESS to Standalone 46 11 4 3 Changing to a Different Large Matrix MACHINE ADDRESS 47 11 5 Choosing the SWITCHING METHOD Setting 48 11 5 1 Understanding the SWITCHING METHOD Settings 48 11 5 2 Configuring a SWITCHING METH...

Page 4: ...nector PINOUT 26 Figure 16 Connecting the RS 485 Connectors between Two VS 162V Units 27 Figure 17 An RS 485 Control Interface Setup 28 Figure 18 Keyboard Extension EXT KEYS Connector 30 Figure 19 Default Startup Status Display Sequence 31 Figure 20 Sequence of MENU Commands 40 Figure 21 Choosing the MTX SYNC from Matrix Setting 49 Figure 22 Choosing what to INDICATE 52 Figure 23 Machine Identific...

Page 5: ...ncludes the following items VS 162V 16x16 Video Matrix Switcher Windows based Kramer control software2 Power cord and null modem adapter This user manual3 2 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual 2 1 Quick Start This quick start chart summarizes the b...

Page 6: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 ...

Page 7: ...transitions when sources share a common reference sync1 Offers excellent video performance which ensures that it remains transparent in almost any video application In addition the VS 162V May be used as a single unit or expanded to up to 96 x 96 inputs outputs Can be configured into a Kramer multi signal switcher system including digital and analog video digital and analog audio and RS 422 contro...

Page 8: ...xternal dry contact push buttons To achieve the best performance Connect only good quality connection cables thus avoiding interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables Avoid interference from neighboring electrical appliances that may adversely influence signal quality and position your Kramer VS 162V in a loca...

Page 9: ...Your Video Matrix Switcher 5 Figure 1 VS 162V 16x16 Video Matrix Switcher ...

Page 10: ...Block Connectors Connects to an external keyboard remote unit 16 RS 485 Detachable Terminal Block Port Pins 1 and 2 are for vertical sync and Ground connection and Pins 3 and 4 are for RS 485 17 RS 232 IN 9 pin D sub F Port Connects to the PC or the Remote Controller 3 18 RS 232 OUT 9 pin D sub M Port Connects to the RS 232 IN 9 pin D sub port of the next unit in the daisy chain connection 19 SETU...

Page 11: ...5 meters away from the machine This distance can be extended to up to 60 meters when used with three extension cables2 Before using the external IR receiver be sure to arrange for your Kramer dealer to insert the internal IR connection cable11F 3 with the 3 5mm connector that fits into the REMOTE IR opening on the rear panel Connect the external IR receiver to the REMOTE IR 3 5mm connector 1 Model...

Page 12: ...re range 5º to 45º C 41º to 113º F Operating humidity range 10 to 90 RHL non condensing Storage temperature range 20º to 70º C 4º to 158º F Storage humidity range 5 to 95 RHL non condensing CAUTION When installing in a 19 rack avoid hazards by taking care that 1 It is located within the recommended environmental conditions as the operating ambient temperature of a closed or multi unit rack assembl...

Page 13: ...tical interval of the external reference In particular be sure that the DIP switches are set as shown in Figure 2 for more information see section 8 Figure 2 DIP Switch Setup on a Single Machine To operate a single machine see Table 2 Table 2 Quick Reference Operating Guide for a Single Machine To perform this command Press Connect an input with an output OUT IN Reset a specific output OUT OFF Res...

Page 14: ...ection describes how to configure your VS 162V as a standalone switcher for Composite video CV see section 7 1 1 s Video Y C see section 7 1 2 YUV RGB see section 7 1 3 RGBS see section 7 1 4 Table 3 defines the number of inputs and outputs for each signal configuration Table 3 Standalone Switcher Configuration for CV Y C YUV RGB and RGBS Configuration Number of Inputs and Outputs on a Standalone ...

Page 15: ...omposite Video CV 7 1 2 Configuring an 8x8 s Video Y C Switcher To configure a single VS 162V switcher as an 8x8 video matrix switcher with 8 inputs and 8 outputs for s Video Y C group the inputs and outputs into pairs as shown in Figure 4 Figure 4 Configuring the VS 162V for s Video Y C ...

Page 16: ...1 Figure 5 into sets of 3 as shown in The YUV channel is also appropriate for RGSB In this case connect Gs for Y R for V and B for U Figure 5 Configuring the VS 162V for YUV RGB 7 1 4 Configuring a 4x4 RGBS Switcher To configure a single VS 162V switcher as a 4x4 video matrix switcher for RGBS group the inputs and outputs into sets of 4 as shown in Figure 6 Figure 6 Configuring the VS 162V for RGB...

Page 17: ...he MATRIX and STATUS LCD displays do not illuminate The slave units follow the master The master unit operates in the regular way1 Note To activate a multi channel video switcher so that each unit is in the same state from the outset turn on the master unit power before turning on the slave units leading the slaves in the background Table 4 16x16 Multi Channel Configurations Configuration No VS 16...

Page 18: ...Unit 16x16 YUV RGB Switcher To configure a 16x16 YUV video matrix switcher combine1 Figure 7 three VS 162V switchers as shown in Figure 7 Configuring a 16x16 YUV RGB Switcher with 3 VS 162V Units 1 For a description of how to connect the RS 485 connectors between the VS 162V switchers refer to section 9 2 ...

Page 19: ... 64 OUTPUTS 17 32 INPUTS 17 32 INPUTS 1 16 INPUTS 33 48 INPUTS 49 64 INPUTS 65 80 MACHINE ADDRESS 7 MACHINE ADDRESS 1 MACHINE ADDRESS 13 MACHINE ADDRESS 19 MACHINE ADDRESS 25 MACHINE ADDRESS 31 MACHINE ADDRESS 8 MACHINE ADDRESS 2 MACHINE ADDRESS 14 MACHINE ADDRESS 20 MACHINE ADDRESS 26 MACHINE ADDRESS 32 INPUTS 81 96 OUTPUTS 33 48 MACHINE ADDRESS 9 MACHINE ADDRESS 3 MACHINE ADDRESS 15 MACHINE ADDR...

Page 20: ...62V units to 1 see section 8 2 2 Set the MACHINE ADDRESS on one VS 162V unit to 1 and on the other VS 162V unit to 7 refer to Figure 8 3 Set DIP 6 OFF on both VS 162V units 4 Using T connectors connect OUTPUTS 1 to 16 on both VS 162V units OUTPUTS 1 to 16 become the SYSTEM OUTPUTS 1 to 16 while the inputs on the MACHINE ADDRESS 1 are system inputs 1 to 16 and the inputs on the MACHINE ADDRESS 7 ar...

Page 21: ...ated as MACHINE ADDRESS 7 next to the INPUT BNCs and put the inputs in MACHINE ADDRESS 1 into Hi Z state release the TERM buttons next to the INPUT BNCs INPUTS 1 to 16 become the SYSTEM INPUTS 1 to 16 7 Terminate the INPUTS on MACHINE ADDRESS 8 to 75 Ω push in the TERM button next to the INPUT BNCs and put the inputs in MACHINE ADDRESS 7 into Hi Z state release the TERM buttons next to the INPUT B...

Page 22: ...cher VS 1616AD a 16x16 digital audio matrix switcher and VS 1616RS an RS 422 control signal matrix switcher The block diagram in Figure 11 illustrates how to assemble an interconnected varied format 16x16 series switcher that consists of a 32x32 composite video matrix switcher a 32x16 digital video matrix switcher a 32x32 balanced stereo audio matrix switcher and a 16x16 digital audio matrix switc...

Page 23: ...her 19 Figure 11 Assembling a System of Interconnected Switchers Refer to section 8 1 for how to set the DIP switches and to section 9 for how to control this group of interconnected varied format 16x16 series switchers and other configurations ...

Page 24: ... panel according to the addressing rule shown in Figure 8 When configuring a mix of different model machines each group of models receives a different MACHINE and each machine is set to a unique MACHINE ADDRESS see section 7 4 8 1 Setting the DIP Switches Configure the VS 162V by setting the 8 DIP switches as Figure 12 and Table 5 define Figure 12 Rear Panel DIP switches Table 5 DIP switch Definit...

Page 25: ... OFF ON ON OFF 14 OFF ON ON ON 7 ON ON ON OFF 15 ON ON ON ON 8 OFF OFF OFF ON 8 3 Setting the MACHINE ADDRESS The MACHINE ADDRESS is determined via the MACHINE ADDRESS Menu command as section 11 4 describes The MACHINE ADDRESS defines which inputs and outputs are configured to that particular unit when expanding as the chart in Figure 8 illustrates A valid MACHINE ADDRESS is from 1 to 36 8 4 Under...

Page 26: ... not illuminate and the STATUS Display shows the following message Keyboard LOCKED However the STATUS Display on each slave VS 162V unit dynamically shows3 Front panel control is via the master VS 162V unit on which the front panel buttons are unlocked and both the MATRIX and STATUS displays illuminate all changes made from the master VS 162V unit 9 Connecting a Control Interface Connect a control...

Page 27: ... of up to 1000 meters 9 1 Connecting the RS 232 Control Interface Connect several switchers from the series of 16x16 matrix switchers and the control unit in an RS 232 daisy chain arrangement with or without using a null modem adapter as shown in Figure 13 The RS 232 daisy chain switcher arrangement is transparent This lets you arrange the switchers from the series of 16x16 matrix switchers accord...

Page 28: ... 9 pin D sub port on the first VS 162V unit and the null modem adapter that attaches to the RS 232 IN 9 pin D sub port on the second VS 162V unit 9 1 2 Connecting Two Units without a Null Modem Adapter To connect two VS 162V units without using a null modem adapter 1 Connect a flat cable1 between the RS 232 OUT 9 pin D sub port on the first VS 162V unit and the RS 232 IN 9 pin D sub port on the se...

Page 29: ...ect a flat cable1 between the 25 pin D sub COM port and the null modem adapter that attaches to the RS 232 IN 9 pin D sub port on the first VS 162V unit 2 Set DIP 7 OFF enabling null modem adapter use2 on the VS 162V unit 9 1 6 Connecting to a 25 pin PC COM Port without a Null Modem Adapter To connect the 25 pin D sub COM port of a PC to a VS 162V unit without using a null modem adapter 1 Connect ...

Page 30: ... 485 connector on one VS 162V unit to an RS 485 connector on one or more other switchers from the series of 16x16 matrix switchers as Figure 16 illustrates 1 Connect the PIN on the first VS 162V unit to the PIN on the second VS 162V unit or other unit 2 Connect the PIN on the first VS 162V unit to the PIN on the second VS 162V unit or other unit 3 If shielded cable is used for an RS 485 connection...

Page 31: ...Figure 17 illustrates the RS 485 line that connects Between each VS 162V unit To the PC via a Kramer Tools VP 43xl Interface Converter connect the 9 pin D sub PC COM port to the RS 232 in 9 pin D sub port on the VP 43xl Next connect the RS 485 port on the VP 43xl to the RS 485 ports on the VS 162V units ...

Page 32: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Connecting a Control Interface 28 Figure 17 An RS 485 Control Interface Setup ...

Page 33: ... the terminal block connectors as Figure 7 illustrates In this case set the first machine to select the sync source from the external sync connector or from the INPUT 1 connector This sync is now available to the other machines via the RS 485 terminal block connector as Figure 15 and Figure 16 illustrate Select the MTX sync on the other machines that receive that sync 9 4 Connecting the KEYBOARD E...

Page 34: ...mitted by a touch screen system PC1 The Kramer RC IR2 Infrared Remote Control Transmitter or other serial controller Dry contact closure switches connected to the keyboard extension 10 1 Startup Display After switching on the power the MATRIX and STATUS2 1 For instructions on using Kramer Windows 95 98 NT TM Control Software refer to the separate user manual included on the CD ROM in pdf format Kr...

Page 35: ...ffered against changing an action in error In the CONFIRM mode2 You have an optional method to help avoid making a mistake Every action requires user confirmation Execution is delayed3 Protection is offered to prevent erroneous switching until the user confirms the action You can key in several actions and then confirm them by pressing the TAKE button once to simultaneously switch several monitors...

Page 36: ...l inputs to several outputs see section 10 4 2 One input to all outputs see section 10 4 3 10 4 1 Switching One Input to One Output Pressing an OUT IN combination when your VS 162V operates in the AT ONCE mode implements the switch immediately To switch one input to one output AT ONCE mode 1 Press the appropriate OUT button The MATRIX display shows the two flashing digits representing the present ...

Page 37: ...you need to execute each OUT IN combination separately see section 10 4 1 When switching many inputs to many outputs it is recommended to toggle to the CONFIRM mode In the CONFIRM mode you can key in several actions and then confirm them by pressing the TAKE button once simultaneously switching several inputs to several outputs To switch several inputs to several outputs in the CONFIRM mode the TA...

Page 38: ...E LED lights 10 4 3 Switching One Input to All Outputs To switch one input to all the outputs in the AT ONCE mode 1 Press the ALL button The MATRIX display shows all the sets of two flashing digits each representing the present input number for that respective output flashing simultaneously The STATUS Display shows the message all OUTs 2 Press the appropriate IN button This input switches to all t...

Page 39: ...he MATRIX display does not show any Input in its place The STATUS Display momentarily shows the message Where x is the output number To clear an output in the CONFIRM mode the TAKE LED is lit 1 Repeat step 1 above 2 Press the OFF button3 The MATRIX display shows the two flashing digits 00 instead of the previous two flashing digits and the TAKE LED flashes The STATUS Display shows4 out x reset the...

Page 40: ...display does not show any Input in its place The STATUS Display momentarily shows the message out x reset Where x is the output number To clear several outputs in the CONFIRM mode the TAKE LED is lit 1 Repeat step 1 above 2 Press the OFF button The MATRIX display shows the two flashing digits 00 instead of the previous two flashing digits and the TAKE LED flashes The STATUS Display shows1 the mess...

Page 41: ...eset ALL connections All the outputs are cleared and the MATRIX display momentarily shows the message To switch one input to all the outputs in the CONFIRM mode the TAKE LED is lit 1 Repeat step 1 above 2 Press the OFF button 1 The TAKE LED flashes and the MATRIX display shows the message Reset ALL Press TAKE to execute 3 Press the TAKE button to confirm All the outputs are cleared and the TAKE LE...

Page 42: ...dy exists Press TAKE to overwrite Pressing the TAKE button replaces the stored setup with the current setup Alternatively press a different OUT button to change the setup 10 6 2 Recalling Setups To recall a setting do the following 1 Press the RCL button The displays show the messages Enter SETUP number use two digit 01 99 RECALL xy Where xy are the OUT buttons 2 Press the appropriate two OUT butt...

Page 43: ... non relevant button such as an IN button 4 Press the TAKE button The specific setup is implemented If trying to recall an empty setup1 11 MENU Commands the MATRIX display would show a message saying that that particular setup is empty and would return you to step 1 above You can press the MENU button up to 13 times in straight sequence to scan the range of commands 1 That is a setup for which no ...

Page 44: ...TAKE next MENU VIDEO FORMAT setting yes TAKE next MENU MACHINE ADDRESS setting yes TAKE next MENU SWITCHING METHOD setting yes TAKE next MENU extended KEYBOARD setting yes TAKE next MENU STORE RECALL setting yes TAKE next MENU what to INDICATE yes TAKE next MENU COMMUNICATION setting yes TAKE next MENU IR REMOTE setting yes TAKE next MENU AUTO store current SETUP yes TAKE next MENU identify MACHIN...

Page 45: ...ion and show on the MATRIX display Either 1 Press the MENU button The MATRIX display shows the message to UNLOCK front panel press TAKE The TAKE LED flashes 2 Press the TAKE button The front panel unlocks5 2 and the MATRIX display momentarily shows the message Front panel UNLOCKED Or 1 Press the TAKE button twice The front panel unlocks and the same messages show as in steps 1 and 2 above 1 Nevert...

Page 46: ...EM mode if at least one other VS 162V unit6 To set the VS 162V unit to function in the Follow SYSTEM mode is set to the Follow SYSTEM mode and these units interconnect via an RS 232 and or RS 485 communication line 1 Press the MENU button twice The MATRIX display shows the message Follow the SYSTEM yes TAKE next MENU 2 Press the TAKE button The displays show the messages set UNIT follow SYSTEM Pre...

Page 47: ...button twice The MATRIX display shows the message FOLLOW the system yes TAKE next MENU 2 Press the TAKE button The displays show the messages BREAKAWAY from system Press TAKE to execute current follow SYS 3 Press the TAKE button again The MATRIX display shows the message the UNIT is set in mode BREAKAWAY from system 11 3 Choosing the Video Format Setting Choose a VIDEO FORMAT setting from a choice...

Page 48: ...her Y C YUV or RGBS 11 4 Setting the MACHINE ADDRESS Press the MENU button until you reach the Setting the MACHINE ADDRESS command Choose the standalone or the large matrix setting You set the MACHINE ADDRESS using the OUTkeys 1 to 9 and 10 for 0 The OUTkeys function on a decimal basis and not on a positional basis For example to enter the 15 press 1 followed by 5 not 15 You can change the MACHINE...

Page 49: ...rix Current Alone1 3 Press the OUT button 2 The TAKE LED flashes and The displays show the messages Change to the LARGE MATRIX Press TAKE to confirm Current 16x162 4 Press the TAKE button again The displays show the messages READY to set MACHINE ADDRESS use OUTkey 1 9 0 Current 1 5 Enter the MACHINE ADDRESS by pressing an OUT button 1 9 0 The STATUS Display shows the message current x Where x is t...

Page 50: ...r system If so it is recommended that you use that address 9 Press the TAKE button again The MATRIX display shows the message Change highest MACH ADDR Press TAKE to confirm 10 Press the TAKE button again The MATRIX display shows the message HIGHEST MACHINE ADDRESS Changed 11 4 2 Changing the Large Matrix MACHINE ADDRESS to Standalone To set the MACHINE ADDRESS 1 Press the MENU button until you rea...

Page 51: ...MACHINE ADDRESS setting yes TAKE next MENU 2 Press the TAKE button The displays show the messages OUTkey 1 Stand Alone UNIT 2 Large Matrix Current Matrix 3 Press the OUT button 2 The displays show the messages set NEW matrix new TAKE leave old MENU current 16x32 4 Press the TAKE button again The displays show the messages READY to set MACHINE ADDRESS use OUTkey 1 9 0 current 1 5 Press an OUT butto...

Page 52: ... 11 5 Choosing the SWITCHING METHOD Setting Section 11 5 1 describes the SWITCHING METHOD settings for standalone units and large matrices Section 11 5 2 describes how to configure a SWITCHING METHOD 11 5 1 Understanding the SWITCHING METHOD Settings Setting the VS 162V unit as a Stand Alone UNIT1 NoVIS switching occurs immediately after completion of front panel or dry contact operation or immedi...

Page 53: ...l block connector2 To choose the MTX SYNC from Matrix setting This reference signal applies to all switchers in the multi switcher system and facilitates switching all VS 162V units simultaneously 3 Figure 21 as shown in Connect the RS 485 terminal block connectors4 Connect and set the video reference signal on one of the video units to EXT external sync or INT 1 internal sync between each switche...

Page 54: ...Press TAKE to configure from INTERNAL Input 1 4 Press the TAKE button The displays show the messages SWITCHING METHOD changed current From In 1 11 6 Choosing the Extended Keyboard Setting Section 9 4 describes how to connect a remote unit Activate or deactivate it by setting the extended Keyboard setting ON or OFF To set the extended KEYBOARD mode do the following 1 Press the MENU button until rea...

Page 55: ...ALL KEYBOARD mode to the AT ONCE mode instead of the CONFIRM default mode do the following for storing recalling setups and is recommended to prevent erroneously storing recalling of setups 1 Press the MENU button until reaching the STORE RECALL setting The MATRIX display shows the message STORE RECALL setting yes TAKE next MENU 2 Press the TAKE button and choose the appropriate Outkey 1 for the A...

Page 56: ...configure 1 scroll SETUP 2 OUTs INs Current OUTs INs 3 Press the OUT button 1 The TAKE LED flashes and The displays show the messages Scroll switcher setup Press TAKE to execute Current OUTs INs 4 Press the TAKE button The displays show the messages display mode changed Current SETUP 11 9 Choosing the COMMUNICATION Setting Choose the response option reply or no reply To choose the No Reply respons...

Page 57: ...ds Table 7 Summary of Basic RC IR2 Setups To execute this command Press the following keys in this sequence Allocate the VS 162V to Group 12 SHIFT GROUP 12 Set the MACHINE UNIT key 3 To enable IR REMOTE control when set OFF do the following according to the VS 162V DIP switch settings 1 Press the MENU button until reaching the IR REMOTE setting The MATRIX display shows the message IR REMOTE settin...

Page 58: ...ave the current setup automatically that is whether to save the machine s status on power down so that it returns to the same status after cycling power To save the current setup automatically when set OFF do the following 1 Press the MENU button until you reach the AUTO Store Current SETUP command The MATRIX display shows the message AUTO store current SETUP yes TAKE next MENU 2 Press the TAKE bu...

Page 59: ... to reset the machine1 Current status to the 2 Factory default resets to the pre installed factory default state reloads the current setup 3 Each VS 162V unit ships in its factory default To reset the machine do the following 1 Press the MENU button until you reach the initial RESET command The MATRIX display shows the message initial RESET yes TAKE next MENU 2 Press the TAKE button The MATRIX dis...

Page 60: ...1616 15 hex to the FLASH memory memory which lets you upgrade to the latest Kramer firmware version in minutes 2 The current VS 162V software version shows in the STATUS display as Figure 19 illustrates in section 10 1 12 1 Connecting the PC to the RS 232 Port Before installing the latest Kramer firmware version on a VS 162V unit connect The COM port on your PC to the RS 232 IN port on the VS 162V...

Page 61: ...few seconds following the initial machine identification message the MATRIX display shows the following message Please release key TAKE 6 Release the TAKE button The TAKE LED flashes and the MATRIX display shows the following message Update program Please confirm TAKE 7 Press the TAKE button The MATRIX display shows the following message YOU will lose current SETUP2 8 Press the TAKE button again T...

Page 62: ...Σ 0807561 12 Observe the PC monitor and the VS 162V MATRIX and STATUS Displays After about 30 seconds the program installation completes the color of the Send button ceases to be red and the numbers inside the blue line disappear The Displays on the VS 162V show the messages Program replaced successfully Σ 16608D 16608D 13 After about 3 seconds The displays show the messages Turn unit OFF reconnec...

Page 63: ...ARITY 0 01 VIDEO S N 70 2 dB DIFF GAIN 0 01 DIFF PHASE 0 01 Deg K FACTOR 0 05 CONTROL 38 selector switches RS 232 RS 485 IR remote dry keyboard extension SWITCHING Vertical interval POWER SOURCE 230V AC 50 60 Hz 115VAC U S A 10VA DIMENSIONS 19 x 7 x 2U W D H rack mountable WEIGHT 3 5kg 7 8lbs approx ACCESSORIES Power cord null modem adapter Windows based Kramer control software OPTIONS External IR...

Page 64: ...81 81 IN 7 01 88 90 81 01 88 8F 81 01 88 8E 81 01 88 8D 81 01 88 8C 81 01 88 8B 81 01 88 8A 81 01 88 89 81 01 88 88 81 01 88 87 81 01 88 86 81 01 88 85 81 01 88 84 81 01 88 83 81 01 88 82 81 01 88 81 81 IN 8 01 89 90 81 01 89 8F 81 01 89 8E 81 01 89 8D 81 01 89 8C 81 01 89 8B 81 01 89 8A 81 01 89 89 81 01 89 88 81 01 89 87 81 01 89 86 81 01 89 85 81 01 89 84 81 01 89 83 81 01 89 82 81 01 89 81 81 ...

Page 65: ...theractsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct claims must bepresentedtothe carrier v Removalorinstallationoftheproduct vi Anyothercause whichdoes not relateto aproduct defect vii Cartons equipment enclosures cables or accessoriesusedinconjunctionwiththeproduct ...

Page 66: ...For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Caution Safety Warning Disconnect the unit from the power supply before opening servicing ...

Reviews: