KRAMER: SIMPLE CREATIVE TECHNOLOGY
Kramer Protocol
40
16.2.2 Command Parts Details
Command:
Sequence of ASCII letters ('A'-'Z', 'a'-'z' and '-')
Command will separate from parameters with at least single space
Parameters:
Sequence of Alfa-Numeric ASCII chars ('0'-'9','A'-'Z','a'-'z' and some special chars for specific commands), parameters will be separated
by commas
Message string:
Every command must to be entered as part of message string that begin with
message starting char
and end with
message closing char
,
note that string can contain more then one command separated by pipe ("|") char
Message starting char:
'#' for host command\query
'~' for machine response
Device address
(Optional, for Knet):
Knet Device ID follow by '@' char
Query sign
= '?', will follow after some commands to define query request
Message closing char =
Host messages - Carriage Return (ASCII 13), will be referred to by
CR
in this document
Machine messages
-
Carriage Return (ASCII 13) + Line-Feed (ASCII 10), will be referred to by
CRLF
Spaces between parameters or command parts will be ignored
Commands chain separator char:
When
message string
contains more than one
command, commands will be separated by pipe ("|")
Commands entering:
If terminal software used to connect over serial \ ethernet \ USB port, that possible to directly enter all commands characters (CR will be
entered by Enter key, that key send also LF, but this char will be ignored by commands parser)
Sending commands from some controllers (like Crestron) require coding some characters in special form (like \X##) Anyway, there is a
way to enter all ASCII characters, so it is possible to send all commands also from controller
(Similar way can use for URL \ Telnet support that maybe will be added in future)
Commands forms:
Some commands have short name syntax beside the full name to allow faster typing, response is always in long syntax
Commands chaining:
It is possible to enter multiple commands in same string by '|' char (pipe)
In this case the
message starting char
and the
message closing char
will be entered just one time, in the string beginning and at the
end
All the commands in string will not execute until the closing char will be entered
Separate response will be sent for every command in the chain
Input string max length:
64 characters
Backward support:
Design note: Transparent support for Protocol 2000 will be implemented by switch Protocol command from Protocol 3000 to Protocol
2000, in Protocol 2000 there is already such a command to switch Protocol to ASCII Protocol (#56 : H38 H80 H83 H81)
Table 12: Instruction Codes for Protocol 3000
Help commands
Command
Syntax
Response
Protocol Handshaking
#CR
~OKCRLF
Device initiated messages
Command
Syntax
Start message
Kramer Electronics LTD. ,
Device Model
Version
Software Version