KRAMER: SIMPLE CREATIVE TECHNOLOGY
Understanding the VP-727
24
Select the
Repeating
frequency (1 to 20 or Forever)
Select the
Font
and Font size
Table 7 describes when the setup parameters are available:
Table 7: TextOverlay Parameters
The Parameter
Before “Start to
Run TextOverlay”
Needs
Send?
Number of accessible buffers
Yes
Display height
Yes
Mode selection
1
Yes
Text Color Effect
Yes
Background Color Effect
Yes
Get resolution
Yes
Normal Color (Text Color)
No
Normal Color (Background Color)
No
V-Position (Text Position)
No
Blank Time (sec)
No
Speed
No
Message
Yes
Repeat
Yes
Buffer
Yes
H-Offset
Yes
Select Font
Yes
8.6.3
Connecting and Disconnecting the TextOverlay Program
To connect the TextOverlay program, do the following:
1. Open the TextOverlay program.
The TextOverlay application screen appears
2
.
2. Select the
VP-727
check box.
3. Select the type of connection to be used
3
:
When selecting RS-232, in the COM port box select the COM port you
want to use and in the Baud Rate box, select 115200
When selecting TCP/IP, in the IP Address box, type the machine IP
and in the Port box type the port you want to use
4. Press the red “ Connect” button.
Once a connection is established, the red “ Connect” button changes to a
green “ Disconnect” button, and the connection type boxes are disabled.
1 Static or Scrolling
2 If required you can load a previously saved setting and continue to step 4 in this procedure
3 If you are loading a previously saved setting, the type of connection is already defined