background image

 

 

RJ-45 Pinout: 

 

DIP-Switch Settings

 

 

For the Ethernet connector, see the wiring diagram 
below: 

 

Changes to the DIP-switches only take effect on power-up. After 
changing a switch, reboot the device. All DIP-switches are set to Off 
(up) by default. 

 

PIN EIA /TIA 568B 

 

PIN 

Wire Color 

 

Feature 

Dip-switch Settings 

Orange / White 

 

Reserved 

 

Orange 

 

Reserved 

 

Green / White 

 

Audio de-
embedding 

On (down) 

– Disable audio de-embedding. Note 

that the audio output port is muted. 
Off (up) 

– Enable audio de-embedding to the 

analog audio output port (default). 

Blue 

 

Green 

Brown / White 

 

Force RGB 

On (down) 

– Force RGB mode. 

Off (up) 

– Normal mode (default) 

Brown 

 

For optimum range and performance use the recommended Kramer cables available at 

www.kramerav.com/product/VM-218DT

. 

 

Step 5:  Connect the power 

Connect the power cord to 

VM-218DT

 and plug it into the mains electricity. 

Safety Instructions  

 

Caution: 

There are no operator serviceable parts inside the unit. 

Warning: 

Use only the power cord that is supplied with the unit.  

Warning: 

Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only. 

Warning: 

Disconnect the power and unplug the unit from the wall before installing.  

Se

www.KramerAV.com

 for updated safety information. 

 

Step 6:  Operate the VM-218DT 

Web pages: 

 

RS-232 and Ethernet: 

 

RS-232/Ethernet 

 

Baud Rate:  

115,200  

Parity:  

None  

Data Bits:  

8  

Command Format: 

ASCII Protocol 3000 

Stop Bits:  

1  

 

 

Example (Route input 1 to output 1): 

#ROUTE 1,1,1 <cr> 

Ethernet Parameters  

 

IP Address:  

192.168.1.39  

 

 

Subnet Mask:  

255.255.0.0  

Default UDP Port #:   50000 

Default Gateway:   192.168.0.1 

 

 

Full Factory Reset 

 

Front Panel 
Buttons: 

Front panel buttons: power off the device, press and hold the 
RESET button for 3 seconds while powering the device, and 
then release. 

Protocol 3000: 

“#factory” command. 

Web Pages: 

In the Device Settings page, click Reset. 

 

Reviews: