RJ-45 Pinout:
DIP-Switch Settings
For the HDBT connector, see the wiring diagram
below:
All DIP-switches are set to OFF (up) by default,
Changes to DIP-switches 4 and 5 only take
effect after power cycling the device.
PIN EIA /TIA 568B
PIN
Wire Color
#
Feature
Dip-switch Settings
1
Orange / White
1
HDBT Range
Mode
OFF
– HDBaseT normal range.
ON
– HDBaseT ultra-long range
(provides increased range at a reduced
bandwidth).
2
Orange
3
Green / White
4
Blue
The ultra-long range mode is
activated when DIP-switch 1 on at
least one of the devices is set to ON.
5
Blue / White
6
Green
7
Brown / White
2
Compression
Level
OFF
– Low compression level is applied.
ON
– High compression level is applied to
gain better extension reach performance.
8
Brown
3
Compressed
Signals
OFF
– Compression is applied only to signal
resolutions higher than 1080p.
ON
– Compression is applied to all signal
resolutions.
Compression can be applied for a
TP-583Txr
/
TP-583Rxr
paired-connection only, thus
preserving backward compatibility
with standard-HDBT extenders.
4, 5
FW Upgrade
OFF, OFF
– Normal operation mode.
ON, OFF
– HDBT FW upgrade mode.
ON, ON
– Compression FW upgrade mode.
When either DIP-switch is set to ON,
the device extension operation is
disabled.
6
IR Frequency
OFF (up)
– Frequency is 38kHz.
ON (down)
– Wide-range modulated IR
frequency.
For optimum range and performance use the
recommended Kramer cables available at
www.kramerav.com/product/TP-583Txr, TP-583Rxr
Step 5: Connect the power
Connect the 12V DC power adapter to
TP-583Txr
/
TP-583Rxr
and plug it into the mains electricity.
Safety Instructions
Caution:
There are no operator serviceable parts inside the unit.
Warning:
Use only the Kramer Electronics power adapter that is provided with the unit.
Warning:
Disconnect the power and unplug the unit from the wall before installing.
for updated safety information.
Step 6: Operate TP-583Txr/TP-583Rxr
Operate
TP-583Txr
/
TP-583Rxr
remotely, by RS-232 serial
commands transmitted by a touch
screen system, PC, or other serial
controller
RS-232 Control
Baud Rate:
57,600
Data Bits:
8
Stop Bits:
1
Parity:
None
Command Format: ASCII