background image

Kramer Electronics, Ltd. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

USER MANUAL 

 

 

Model: 

TP-400FW 

FireWire Range Extender 

 

 

Summary of Contents for TP-400FW

Page 1: ...Kramer Electronics Ltd USER MANUAL Model TP 400FW FireWire Range Extender...

Page 2: ...fications 7 Figures Figure 1 TP 400FW FireWire Range Extender 3 Figure 2 Connecting 2 FireWire Devices Standard 4 5m Range 4 Figure 3 Connecting 2 FireWire Devices via 2 TP 400FW Units Extended 100m R...

Page 3: ...at only SHIELDED CABLES should be used with the TP 400FW Amendment to Section 3 In the following text Enables 1394 100Mbps signals to be transmitted and received across an extended range on unshielded...

Page 4: ...uge CAT5 cable Shielded Twisted Pair STP Unshielded Twisted Pair UTP The decision whether to use shielded twisted pair STP cable or unshielded twisted pair UTP cable depends on the nature of the appli...

Page 5: ...xtend the standard 4 5m 13 5ft FireWire range considerably to up to 100m 300ft with 2 interconnected units and up to 200m 600ft with 3 interconnected units etc using inexpensive widely used CAT 5 cabl...

Page 6: ...ransient high voltages down to the allowed level In particular ESD protection for high speed data lines to IEC 61000 4 2 ESD 15kV air 8kV contact IEC 61000 4 5 Lightning 12A 8 20us and IEC 61000 4 4 E...

Page 7: ...en a fully functioning FireWire device and the FireWire port on the front panel item 7 in Table 1 5 CONNECTION STATUS Green LEDs FW REAR Lights when a connection is established between a fully functio...

Page 8: ...IGHT connector is always the source of the power and the CAT 5 CROSSED connector is always the acceptor of the power 2 Connect the CAT 5 Straight RJ45 connector on the first TP 400FW unit to the CAT 5...

Page 9: ...ns for the picture to appear on the destination device If the picture fails to appear on the destination device after 5 seconds press the RESET Button to reboot the setup Wait another 5 seconds for th...

Page 10: ...e device for example a PC to the FW PORT F on the third TP 400FW unit 4 Be sure that the power on each device is turned ON The relevant CONNECTION STATUS green LEDs light see items 2 3 4 and 5 in Tabl...

Page 11: ...NSFER RATE 100Mbps IEEE 1394 STANDARDS IEEE 1394a 2000 IEEE 1394 1995 IEEE 1394b 2002 up to 100Mbps ESD LINE PROTECTION IEC 61000 4 2 ESD 15kV air 8kV contact IEC 61000 4 5 Lightning 12A 8 20us and IE...

Page 12: ...s required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name...

Page 13: ...m P N 2900 000005 REV 1 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com Updates to this user manual may be found at http www k...