3.2  Shielded Twisted Pair (STP)/Unshielded Twisted Pair (UTP) 

We recommend that you use Shielded Twisted Pair (STP) cable. There are 

different levels of STP cable available, and we advise you to use the best 

quality STP cable that you can afford. Our non-skew-free cable, Kramer 

BC-STP

 is intended for analog signals where skewing is not an issue. For 

cases where there is skewing, our UTP skew-free cable, Kramer 

BC-XTP

may be used. Bear in mind, though, that we advise using STP cables where 

possible, since the compliance to electromagnetic interference was tested 

using those cables. 
Although Unshielded Twisted Pair (UTP) cable might be preferred for long 

range applications, the UTP cable should be installed far away from electric 

cables, motors and so on, which are prone to create electrical interference.  

However, since the use of UTP cable might cause inconformity to 

electromagnetic standards, Kramer does not commit to meeting the standard 

with UTP cable. 

3.3  Recommendations for Achieving the Best Performance 

To achieve the best performance: 

 

Use only good quality connection cables

1

 

Avoid interference from neighboring electrical appliances that may 

adversely influence signal quality and position your Kramer 

TP-310A 

away from moisture, excessive sunlight and dust 

 to avoid interference, 

deterioration in signal quality due to poor matching, and elevated noise 

levels (often associated with low quality cables). 

Your TP-310A UXGA Line Receiver/DA 

Figure 1

 and 

Table 1

 define the 

TP-310A

                                                       

 

1 Available from Kramer Electronics on our Web site at 

http://www.kramerelectronics.com

 

Summary of Contents for TP-310A

Page 1: ...Kramer Electronics Ltd USER MANUAL Model TP 310A UXGA Line Receiver DA...

Page 2: ...necting Additional TP 310A UXGA Line Receiver DA Units 11 6 3 Wiring the CAT 5 LINE IN LINE OUT RJ 45 Connectors 13 6 4 Wiring the RS 232 Connector 13 7 Technical Specifications 14 Figures Figure 1 TP...

Page 3: ...310A UXGA Line Receiver DA Power cord2 This user manual3 2 Getting Started We recommend that you Unpack the equipment carefully and save the original box and packaging materials for possible future sh...

Page 4: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps...

Page 5: ...0A is housed in a 19 1U rack mountable enclosure with rack ears included and is fed from a 100 240V AC universal switching power supply 3 1 About the Power Connect Feature The Power Connect feature ap...

Page 6: ...nge applications the UTP cable should be installed far away from electric cables motors and so on which are prone to create electrical interference However since the use of UTP cable might cause incon...

Page 7: ...Your TP 310A UXGA Line Receiver DA 5 Figure 1 TP 310A UXGA Line Receiver DA...

Page 8: ...ors G and Tx1 to control a device see section 6 3 G Tx2 Connect the two connectors G and Tx2 to control a device see section 6 3 14 Power Connector with Fuse AC connector enabling power supply to the...

Page 9: ...Installing in a Rack 7 5 Installing in a Rack This section provides instructions for rack mounting the 1U unit...

Page 10: ...o jack 4 An RS 232 cable with a 9 pin D sub connector at one end to the laptop and a 2 PIN terminal block connector at the other end to the TP 123 RS 232 port 2 On the TP 310A connect the UXGA OUT 1 1...

Page 11: ...RJ 45 connector on the TP 123 to the LINE IN RJ 45 connector on the TP 310A via STP cabling with a range of up to 300ft up to100m see section 3 2 5 Connect the power cord5 6 If necessary set the HS a...

Page 12: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Configuring the TP 310A UXGA Line Receiver DA 10 Figure 3 Connecting the TP 310A UXGA Line Receiver DA system...

Page 13: ...can distribute the signal to 10 receivers The system in total distributes the signal to 37 receivers To connect an expanded UXGA Line Receiver DA system do the following 1 Connect a transmitter to th...

Page 14: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Configuring the TP 310A UXGA Line Receiver DA 12 Figure 4 Distributing the Signal to 37 Receivers Transmitter TP 46 TP 46 TP 124 TP 122 TP 124 TP 122 TP 122 TP 124...

Page 15: ...ange 6 Green 7 Brown White 7 Brown White 8 Brown 8 Brown Pair 1 4 and 5 Pair 1 4 and 5 Pair 2 3 and 6 Pair 2 1 and 2 Pair 3 1 and 2 Pair 3 3 and 6 Pair 4 7 and 8 Pair 4 7 and 8 6 4 Wiring the RS 232 C...

Page 16: ...nal block for 2 RS 232 TxD out lines MAX OUTPUT LEVEL VIDEO 1 3Vpp 75Vpp Audio 2 3V 10k POWER OUTPUTS 12V DC 0 5A max via each RJ 45 output PINs 4 5 RESOLUTION Up to UXGA BANDWIDTH 3dB Audio 20Hz to 2...

Page 17: ...heractsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct claims must bepr...

Page 18: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...

Reviews: