3.1 

About the Power Connect Feature 

The Power Connect feature applies as long as the cable can carry power. 
This feature is available when using STP cable and the distance does not 
exceed 50m on standard CAT 5 cable. For longer distances, heavy gauge 
cable should be used

1

.

 

For units which are connected via RJ-45 connectors, 

make sure that the shield of the STP cable is connected to the metal casing 
of the connectors on both ends of the cable. For units which are connected 
via terminal block connectors, the shield of the STP cable must be 
connected to a ground terminal on the units at both ends (use the ground 
terminal of the power supply connection if necessary). 

For a CAT 5 cable exceeding a distance of 50m, separate power supplies 
should be connected to the transmitter and to the receiver simultaneously.

 

3.2 

Shielded Twisted Pair (STP)/Unshielded Twisted Pair (UTP) 

We recommend that you use Shielded Twisted Pair (STP) cable. There are 
different levels of STP cable available, and we advise you to use the best 
quality STP cable that you can afford. Our non-skew-free cable, Kramer 

BC-STP

 is intended for analog signals where skewing is not an issue. For 

cases where there is skewing, our UTP skew-free cable, Kramer 

BC-XTP

may be used. Bear in mind, though, that we advise using STP cables where 
possible, since the compliance to electromagnetic interference was tested 
using those cables. 

Although Unshielded Twisted Pair (UTP) cable might be preferred for long 
range applications, the UTP cable should be installed far away from electric 
cables, motors and so on, which are prone to create electrical interference.  
However, since the use of UTP cable might cause inconformity to 
electromagnetic standards, Kramer does not commit to meeting the standard 
with UTP cable. 

 
 
 
 
 
 
 
 
 

                                                       

 

1 CAT 5 cable is still suitable for the video/audio transmission, but not for feeding the power at these distances 

Summary of Contents for TP-305A

Page 1: ...Kramer Electronics Ltd Preliminary USER MANUAL Model TP 305A UXGA Audio RS 232 Line Receiver DA...

Page 2: ...Units 8 5 3 Wiring the CAT 5 LINE IN LINE OUT RJ 45 Connectors 10 5 4 Wiring the RS 232 Connector 10 6 Technical Specifications 11 Figures Figure 1 TP 305A UXGA Audio RS 232 Line Receiver DA 5 Figure...

Page 3: ...includes the following items TP 305A UXGA Audio RS 232 Line Receiver DA Power supply 12V DC This user manual2 2 Getting Started We recommend that you Unpack the equipment carefully and save the origi...

Page 4: ...witches Set the Hs and Vs polarity switches Step 2 Set the underside switches see section 5 Step 2 Set the underside switches see section 5 A OUT UDIO L IN INE T P 1 2 4 XGA OUT X G A A u d io D a t a...

Page 5: ...tput S PDIF on an RCA connector and an analog audio output on a 3 5mm mini jack A transmission range of up to 300ft up to 100 meters over STP cabling Changeable polarity of the encoded H and V Sync fo...

Page 6: ...2 Shielded Twisted Pair STP Unshielded Twisted Pair UTP We recommend that you use Shielded Twisted Pair STP cable There are different levels of STP cable available and we advise you to use the best qu...

Page 7: ...LINE OUTPUT RJ 45 Connectors Connect to4 the LINE IN RJ 45 connector on a receiver5 from 1 to 5 8 AUDIO OUT ANALOG 3 5mm Mini Jack Connect to the stereo analog audio acceptor 1 9 S PDIF RCA Connector...

Page 8: ...ers and up to five TP 305A units can be connected to increase the number of outputs to 25 5 1 Connecting a Single TP 305A To connect a TP 123 TP 305A UXGA Audio RS 232 Line Receiver DA system3 as illu...

Page 9: ...up to 300ft up to 100m 5 The LINE OUTPUT 5 RJ 45 connector on the TP 305A to the LINE IN RJ 45 connector on another TP 1243 unit via STP cabling4 with a range of up to 300ft up to 100m 4 Connect the 1...

Page 10: ...ine Receiver DA system do the following 1 Connect a transmitter to the LINE IN RJ 45 connector of the first TP 305A 2 Connect the LINE OUTPUT 1 RJ 45 connector of the first TP 305A to the LINE IN RJ 4...

Page 11: ...45 connector of the fourth TP 305A 5 Connect the LINE OUTPUT RJ 45 connectors of each TP 305A unit to the LINE IN RJ 45 connectors of the appropriate receivers as illustrated in Figure 4 6 On each TP...

Page 12: ...White 5 Blue White 6 Orange 6 Green 7 Brown White 7 Brown White 8 Brown 8 Brown Pair 1 4 and 5 Pair 1 4 and 5 Pair 2 3 and 6 Pair 2 1 and 2 Pair 3 1 and 2 Pair 3 3 and 6 Pair 4 7 and 8 Pair 4 7 and 8...

Page 13: ...232 TxD out line MAX OUTPUT LEVEL Video 1 6V Audio 2 3V POWER OUTPUTS 12V DC 0 5A max via each RJ 45 output pins 4 5 RESOLUTION WUXGA 1080p BANDWIDTH 20Hz to 20kHz 1dB audio SAMPLING RATE FOR S PDIF 4...

Page 14: ...suse abuse neglect fire water lightning or otheractsofnature ii Product modification or failure to follow instructions supplied withtheproduct iii Repairorattemptedrepairby anyonenot authorizedbyKrame...

Page 15: ...st information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feed...

Reviews: