background image

KRAMER:  SIMPLE CREATIVE TECHNOLOGY

 

Setting the DIP-switches on the TP-185 

 

12 

7.1.4 

Setting the RS-232/RS-485 Baud Rate DIP-switches   

DIP-switches 5, 6 and 7 set the serial port baud rate in both Hardware and Software 
modes according to 

Table 4

.  

Note:

 In a multiple device configuration, all devices must be set to the same baud 

rate. 

 

Figure 7: TP-185 Baud Rate DIP-switches 

Table 4: Serial Port Baud Rate DIP-switch Setting 

Baud Rate 

DIP-switch 

 

Baud Rate 

DIP-switch 

 

1200 

OFF 

OFF 

OFF 

 

19200 

OFF  OFF  ON 

2400 

ON 

OFF 

OFF 

 

38400 

ON 

OFF  ON 

4800 

OFF 

ON 

OFF 

 

57600 

OFF  ON 

ON 

9600 (default) 

ON 

ON 

OFF 

 

115200 

ON 

ON 

ON 

7.1.5 

Selecting Hardware/Software Mode 

DIP-switch 8 sets the operating mode to either Hardware or Software mode.  

 

Figure 8: TP-185 Baud Rate Hardware/Software DIP-switch 

When the DIP-switch is: 

 

 

OFF, the unit is set to Hardware mode (default) 

 

ON, the unit is set to Software mode 

7.1.5.1  Hardware Mode 

In Hardware mode, the: 

 

RS-232 data is passed from any input to all outputs 

 

TP-185

 routes the reply from the output port defined by the DIP-switches 2, 3 

and 4 (see 

Section  7.1.2

). For reliable operation, only one port can be defined  

Summary of Contents for TP-185

Page 1: ...Kramer Electronics Ltd USER MANUAL Model TP 185 8 Channel UXGA Audio RS 232 to CAT 5 Transmitter...

Page 2: ...he Reply Feature 10 7 1 3 Setting the Reply Source or Machine Number 11 7 1 4 Setting the RS 232 RS 485 Baud Rate DIP switches 12 7 1 5 Selecting Hardware Software Mode 12 8 Wiring the Twisted Pair RJ...

Page 3: ...3 Software Mode RS 485 Machine Number DIP switch Setting 11 Table 4 Serial Port Baud Rate DIP switch Setting 12 Table 5 UTP Connector Pinout 13 Table 6 Technical Specifications of the TP 185 14 Table...

Page 4: ...package includes the following items TP 185 8 Channel UXGA Audio RS 232 to CAT 5 Transmitter Power cord2 rack ears and this user manual3 2 Getting Started We recommend that you Unpack the equipment ca...

Page 5: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Getting Started 2 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps...

Page 6: ...quality due to poor matching and elevated noise levels often associated with low quality cables Avoid interference from neighboring electrical appliances that may adversely influence signal quality a...

Page 7: ...XGA Audio RS 232 to CAT 5 Transmitter 4 4 Defining the TP 185 8 Channel UXGA Audio RS 232 to CAT 5 Transmitter Figure 1 and Table 1 define the front and rear panels of the TP 185 8 Channel UXGA Audio...

Page 8: ...etermines the serial port baud rate see Section 7 1 4 Hardware Software DIP switch 8 Determines whether the data transmission path is set by software or hardware see Section 7 1 5 7 AC Mains Connector...

Page 9: ...KRAMER SIMPLE CREATIVE TECHNOLOGY Installing the TP 185 in a Rack 6 5 Installing the TP 185 in a Rack This section describes what to do before installing in a rack and how to rack mount the TP 185...

Page 10: ...e TP 185 To connect1 the TP 185 as illustrated in the example2 in Figure 2 Figure 2 Connecting the TP 185 8 Channel UXGA Audio RS 232 to CAT 5 Transmitter 1 You do not need to connect all inputs and o...

Page 11: ...232 device 3 Connect the RS 232 G pin on the TP 185 to pin 5 9 pin D sub on the RS 232 device 6 3 Connecting to the TP 185 via an RS 485 Connection You can operate the TP 185 via the RS 485 port from...

Page 12: ...TP 185 to the RS 485 terminal block of the second TP 185 and so on see Section 6 3 2 Set each TP 185 Machine number to be a unique number see connecting all the TP 185 units via the RS 485 terminal b...

Page 13: ...DIP switch requires that you cycle power on the TP 185 7 1 1 Setting the RS 485 Bus Termination The DIP switch sets the RS 485 bus termination Only the first and last physical device on the RS 485 bus...

Page 14: ...m output 2 ON OFF OFF Reply is taken from output 3 OFF ON OFF Reply is taken from output 4 ON ON OFF Reply is taken from output 5 OFF OFF ON Reply is taken from output 6 ON OFF ON Reply is taken from...

Page 15: ...5 6 7 1200 OFF OFF OFF 19200 OFF OFF ON 2400 ON OFF OFF 38400 ON OFF ON 4800 OFF ON OFF 57600 OFF ON ON 9600 default ON ON OFF 115200 ON ON ON 7 1 5 Selecting Hardware Software Mode DIP switch 8 sets...

Page 16: ...n The TP 185 differentiates between the two types of commands and acts accordingly The sequence is as follows 1 Set destination path for command 2 Set return path 3 Send end user command sequence 8 Wi...

Page 17: ...ANDWIDTH AUDIO 20Hz to 20kHz 0 5dB S N RATIO AUDIO 80dB TOTAL GAIN Audio 0dB COUPLING Audio AC AUDIO THD NOISE Audio 0 03 POWER CONSUMPTION 100 240V AC 16VA OPERATING TEMPERATURE 0 to 55 C 32 to 131 F...

Page 18: ...efined as 1 I6 I0 INPUT When switching ie instruction codes 1 and 2 the INPUT 7 bits is set as the input number which is to be switched Similarly if switching is done via the machine s front panel the...

Page 19: ...ple outputs for the reply NOTE 3 The reply to this command is as follows The same command and output codes as were sent are returned and the input is assigned the value of the parameter that was read...

Page 20: ......

Page 21: ...REV 1 For the latest information on our products and a list of Kramer distributors visit www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and...

Reviews: