TBUS-5xl - Technical Specifications of the Assembled TBUS-5xl 

 

Technical Specifications of the Assembled 
TBUS-5xl 

POWER SOURCE 
(AC power limits): 

Power Socket Assemblies 

Universal 

100-240V AC, 50/60Hz, 5A 

Maximum 5A per power outlet 

Fully compatible

 with power plugs in the UK, India, Italy 

and Denmark, as well as with the 2-prong Europlug. 

Partially compatible

 (if the polarity is reversed) with 

plugs in China, Switzerland, Israel and the USA. The 
universal socket does not supply grounding to plugs in 
Central Europe and France (you should order country 
specific sockets instead). 

Not compatible

 with South African plugs. 

USA 

100-240V AC, 50/60Hz, 5A 

Maximum 5A per power outlet 

Germany and EU 

100-240V AC, 50/60Hz, 5A 

Maximum 5A per power outlet 

Belgium and France 

100-240V AC, 50/60Hz, 5A 

Maximum 5A per power outlet 

Italy 

100-240V AC, 50/60Hz, 5A 

Maximum 5A per power outlet 

Australia 

100-240V AC, 50/60Hz, 5A 

Maximum 5A per power outlet 

Israel 

220V AC, 50/60Hz, 5A 

Maximum 5A per power outlet 

South Africa 

220V AC, 50/60Hz, 5A 

Maximum 5A per power outlet 

FUSE RATING: 

T 6.3A 250V 

OPERATING TEMPERATURE 
RANGE: 

+5 to +45 Deg. Centigrade 

OPERATING HUMIDITY 
RANGE: 

10 to 90% RHL, non-condensing 

STORAGE TEMPERATURE 
RANGE: 

-20 to +70Deg. C. 

STORAGE HUMIDITY RANGE:  5 to 95% RHL, non-condensing 

DIMENSIONS: 

Top plate: 176mm x 140.4mm (6.9" x 5.5") W, D 
Enclosure: 136mm x 102mm x 130mm (5.4" x 4.0" x 5.1") 
W, D, H 

WEIGHT: 

TBUS-5: 1.52kg (3.35lb) approx.  
Table clamps: 0.257kg (0.566lbs)  
Template: 0.125kg (0.275lbs)) 

ACCESSORIES: 

Power cord, six self-locking ties, template, template screws 

OPTIONS: 

Inner frames, passive wall plates and interfaces, power 
socket kits, power cord  

Specifications are subject to change without notice a

www.kramerav.com

 

Summary of Contents for TBUS-5XL

Page 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL MODULAR TBUS 5xl Table Connection Bus P N 2900 300070 Rev 3...

Page 2: ......

Page 3: ...ling the Inner Frame 11 5 3 Cutting an Opening in the Table 11 5 4 Inserting the TBUS 5xl through the Cut Out Opening 12 5 5 Connecting the Cables 13 5 6 Inserting the Pass through Cables 13 5 7 Adjus...

Page 4: ...hat are clearly defined by function GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repea...

Page 5: ...ng the Best Performance To achieve the best performance Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels oft...

Page 6: ...omized colors can also be ordered Height adjustment screw holes to set the inner frame ordered separately to the desired height Power socket openings that are suitable for any of the following power s...

Page 7: ...hen mounting the unit one for each clamp 5 Locking Butterfly Screws Tighten to lock the mounting butterfly screw one for each clamp 6 Mounting Brackets Fit in the bracket slits after inserting the enc...

Page 8: ...ctor 1 VGA 15 pin HD connector 1 RJ 45 Ethernet connector A 3 5mm mini jack AUDIO connector T5F 13 P N 80 004099 1 opening for 1 power socket 2 blank inserts 1 cable pass through insert Custom made in...

Page 9: ...oes not supply grounding to plugs in Central Europe and France and so you should order country specific sockets instead Not compatible with South African plugs Socket Type Power Specs Socket Type Powe...

Page 10: ...et USA TS 2US 80 001999 100 125V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Belgium and France TS 2FR 80 002299 100 240V AC 50 60Hz 5A Maximum 5A 2 5A per power outlet Germany and EU TS 2DE 80 002...

Page 11: ...d Options You can order any of the following power cords to use with a modular TBUS Power Cord Type Description P N 6ft 110V North America C AC US 110V 91 000099 6ft 125V Japan C AC JP 125V 91 000699...

Page 12: ...gh the opening and secure to the table see Section 5 4 5 Connect the cables see Section 5 5 6 Insert the pass through cables see Section 5 6 7 Adjust the height of the inner frame see Section 5 7 5 1...

Page 13: ...plate 2 Place the required Kramer insert over the opening insert the two screws to fix the Kramer insert in place and tighten them Figure 3 TBUS 5xl Inner Frame P N 80 004099 Feature Function 1 Blank...

Page 14: ...nstructions 5 3 Cutting an Opening in the Table To cut an opening in the table 1 Place the included cut out template that is included with your TBUS 5xl on the surface of the table exactly where you w...

Page 15: ...d from around the outer rim of the TBUS 5xl housing Beware of the sharp edge 2 Carefully insert the unit into the prepared opening see Figure 5 3 Take the support brackets under the table and place th...

Page 16: ...the Pass through Cables When replacing a blank insert with the pass through insert for example to connect a laptop do the following 1 Remove the two screws attaching the split pass through bracket 2...

Page 17: ...djust the inner frame heights to accommodate large or bulky cables To adjust perform the following 1 Remove the height adjustment screws while supporting the surface from underneath with your fingers...

Page 18: ...Using the TBUS 5xl Once the TBUS 5xl is installed you can easily customize it to suit your own requirements by plugging in the required A V equipment as illustrated in the example in Figure 6 Figure 6...

Page 19: ...m and France 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Italy 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Australia 100 240V AC 50 60Hz 5A Maximum 5A per power outlet Israel 220V AC 50...

Page 20: ......

Page 21: ...s visit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerav com E mail info kramerel com P N 2900 300070 Rev 3 SAFETY WARN...

Reviews: