Страница 1: ...PowerCable xxx 101x MANUAL PowerCable Modbus 101x PowerCable MQTT 101x PowerCable REST 101x 29 4 2020 ...

Страница 2: ...Outputs Energy measurements 26 6 1 2 Outputs General 27 6 2 M2M API Protocol Actions 29 6 3 Cloud 30 6 4 Users 33 6 5 Settings 35 6 5 1 Wi Fi 35 6 5 2 Network Configuration 36 6 5 3 Date Time 38 6 5 4 Firmware 39 6 5 5 System 41 6 6 Log 43 7 PowerCable REST 101x 44 7 1 Overview 44 7 2 M2M API Protocol XML REST M2M API 45 7 3 M2M API Protocol JSON REST M2M API 49 7 4 M2M API Protocol URL API REST M...

Страница 3: ...3 ...

Страница 4: ... device does not fall 7 Only elect rical appliances approved for use in the electrical network may be connect ed to t he device 8 Do not connect multiple devices in series 9 The cable plug must be easily accessible 10 The device is complet ely switched off only when unplugged from t he wall socket 11 If the device malfunctions disconnect it from t he electrical power supply and contact your vendor...

Страница 5: ... LAST 1 2m cable Overvoltage protection Operating temperat ure range 20 C to 65 C Supported protocols DNS NTP DHCP HTTP Supported M2M protocols PowerCable Modbus 101x Modbus TCP Telnet SNMP PowerCable MQTT 101x MQTT Htt p s Push SNMP PowerCable REST 101x XML API JSON API URL API SNMP ...

Страница 6: ...Protocol PowerCable Modbus 101x PowerCable REST 101x PowerCable MQTT 101x Web int erface Yes Yes Yes Telnet Yes Modbus TCP Yes URL API Yes XML API Yes JSON API Yes MQTT flex Yes Netio Push JSON Yes Netio Push XML Yes SNMP v1 Yes Yes Yes PowerCable Modbus 101x PowerCable REST 101x PowerCable MQTT 101x NETIO Cloud Yes Yes Yes NETIO Mobile2 Yes Yes Yes ...

Страница 7: ...t plug Voltage Max current Max load 101F DE Type F E F CEE 7 7 230V 16A 3600W 101E FR Type E E F CEE 7 7 230V 16A 3600W 101J CH Type J Type J 230V 10A 2300W 101S IEC 320 C13 C14 IEC 320 C13 IEC 320 C14 110 230V 10A 2300W 101B US Type B Type B 110V 15A 1600W 101G UK Type G Type G 230V 13A 3000W ...

Страница 8: ...ompatible Capacitive load compatible Inductive load compatible Interfaces PowerCable xxx 101x 1x Wi Fi 802 11b g n 2 4 GHz internal antenna with WEP WPA WPA2 Environment IP30 protection rating class 1 Operating temperature 20 65 C 6A load max 63 C 10A max 50 C 16A max 30 C Device rated for pollution degree 2 Designed for continuous operation in altitudes up to 2000m No additional cooling required ...

Страница 9: ...ypes NETIO products a s supplies the PowerCable xxx 101x in several variants with different electrical plug outlet types Figure 1 PowerCable xxx 101F DE schuko Type F Figure 2 PowerCable xxx 101E FR Type E Figure 3 PowerCable xxx 101J CH Type J ...

Страница 10: ...10 Figure 4 PowerCable xxx 101S IEC 320 C13 C14 Figure 5 PowerCable xxx 101B US Type B Figure 6 PowerCable xxx 101G UK Type G ...

Страница 11: ...tion is particularly important in case of frequent switching IOC Independent Output Control Independent Out put Control function of the PowerCable uses an independent system that ensures a stable operation of the output even if t he main system is being restarted updated or is booting Thanks to IOC the controlled out put can power devices that for t echnical reasons must be powered without int err...

Страница 12: ...list and type t he password NETIO PowerCable t hen confirms the connection to t he network and displays the assigned IP address NETIO PowerCable devices can be discovered in the LAN using t he NETIO Discover tool NFC Preconfig PowerCable can be pre configured using NFC even without being switched on This require a mobile phone with Android system NFC function and mobile application NETIO Mobile 2 ...

Страница 13: ...13 4 3 Drawings Figure 7 PoweCable xxx 101x side view Figure 8 PoweCable xxx 101x t op view ...

Страница 14: ...e model electrical rating maximum switching power and serial number fig 11 5 Warning Do not open the device risk of electric shock Rear view Figure 10 PoweCable xxx 101x bot t om view Figure 11 PoweCable xxx 101x t ype plat e SN on the type plate xx 24A42C381234 WiFi network PowerCable AP xx PowerCable AP 34 Front view Figure 9 PoweCable xxx 101x t op view ...

Страница 15: ...apidly for 1 second then yellow LED starts flashing rapidly LED indicators Status LED 1 Yellow Off No WiFi connection On WiFi connected Rapidly flashing red is off AP mode Slowly flashing red is off Restoring WiFi connection Waiting for DHCP 3 fast flashes every second red is off Locate function for one minute after enabling in the web administration Red Flash Activity command received over M2M Ou...

Страница 16: ...16 4 7 Package contents NETIO PowerCable product Quick Installation Guide QIG Figure 11a PoweCable xxx 101x package ...

Страница 17: ...of a WiFi network to which t he device will connect yellow LED flashes rapidly On a computer tablet or smartphone display available WiFi networks and connect to the unsecured PowerCable AP xx network Figure 12 Device configuration page should open automatically If not open a web browser and ent er http 10 0 42 1 You will see NETIO PowerCable WiFi configuration page Figure 13 Figure 12 Connect ing ...

Страница 18: ...e Figure 15 Connect ing t o Wi Fi in AP mode If you do NOT use a DHCP server in your network set the following parameters AP Password password for the network to which t he PowerCable will be connected Client IP IP address in your network address range Client mask network mask for your network Gateway gateway for your network DNS DNS server for your network or a public DNS e g 8 8 8 8 Device name ...

Страница 19: ... t hen click Save Connect t o save the configuration Figure 17 The device t hen exits the AP mode connects to the selected WiFi network and displays a network configuration summary page Figure 18 WiFi connect ion is indicated wit h the yellow LED Figure 17 Configured Wi fi paramet ers Figure 18 Net work connect ion info ...

Страница 20: ...O Mobile2 for Android NETIO Mobile2 application is for control NETIO devices produced after 2016 Features Install NFC enabled NETIO devices Switch On Off each power socket on local network Show power consumption on each power out put if support ed Searching NETIO devices in local network https play google com store apps details id cz netio netio 5 3 Detecting and configuring the IP address If you ...

Страница 21: ...5 3 and then configuring it according to chapter 5 1 Figure 20 Discovering and conf iguring net work paramet ers using NETIO Discover To change the IP address click t he value in the MAC address column uncheck Enable DHCP and specify the IP address Subnet mask and Default gateway After applying t he set tings PowerCable will be accessible at the specified address Ent er t he IP address into a web ...

Страница 22: ...22 5 4 Login to device web Figure 21 PowerCable login dialog To log in use admin admin default login username password ...

Страница 23: ...dure Turn off the PowerCable Press and hold t he button and power up t he PowerCable Hold t he button for about 10 seconds until t he green LED flashes 3x t hen release Figure 22 LED indicat ion when rest oring fact ory def ault s Forgotten password The reset to factory defaults is also used when the password has been forgotten After restoring the factory defaults the username and password to acce...

Страница 24: ...24 5 6 Controlling the output manually The output can be switched on off toggled by pressing the button quickly 3 times in a row Figure 23 LED indicat ion for manual out put cont rol ...

Страница 25: ...4 Cont rolling t he out put The ON OFF button cont rols the output directly When the output is on the button is green when the output is off the button is grey When switching t he output off a confirmation dialog appears Click Turn Output Off to confirm the switch off or Cancel to keep the out put switched on To suppress this dialog in t he fut ure check Don t ask me again ...

Страница 26: ...rgy measurements PowerCable measures the following electrical parameters every 500ms The display in t he web interface is updated every 5 seconds Figure 25 Measured values Load in watts W corresponds to the immediate current and voltage P U I TPF Current in amps A shows the immediate current flowing through t he out put TPF True Power Factor shows the ratio of active and apparent power or the rati...

Страница 27: ... to open detailed settings The General tab configures basic parameters for cont rolling the output Figure 26 General out put conf igurat ion Output name is shown above the two control buttons to improve clarity Short ON OFF delay is an integer specifying in milliseconds the duration for t he Short OFF power cycling and Short ON actions During t his interval any at tempts to switch t he output stat...

Страница 28: ...28 Figure 27 Reset t ing t he consumpt ion count er ...

Страница 29: ...if the out put was on it will be turned off 4 toggle toggles t he current output state 5 no operation leaves the output unchanged 6 ignore ignores the act ion attribute and only respects the st at e attribut e only for XML and JSON The settings for individual M2M protocols supported by the respective PowerCable versions are described in detail at the end of this manual 1 2 The short off short on d...

Страница 30: ...Off for defined time Show power consumption kWh per output met ered device only Settings Output name can be modified Outputs can be placed to any of groups Short OFF restart int erval for reset can be set up NETIO Cloud is a paid service but the current customers will gain some free credits with each device added to their NETIO Cloud account Figure 27a NETIO Cloud Note Cloud is available only in F...

Страница 31: ...connect ed t o Cloud Cloud connect faild reconnecting Device it t rying t o connect t o Cloud Connected Device connect ed t o NETIO Cloud Connected and sychronised Device connect ed t o NETIO Cloud and account informat ion synchronized Last update Dat e and t ime of t he last updat e Added to account Account name t o what t his device is assign Device UID Unique device ID ...

Страница 32: ... but t on used Then press Add device but t on Remove device If t his device is connect ed t o NETIO Cloud use t his butt on to remove disconnect it from NETIO Cloud Account info Use Reload but t on t u refresh account informat ion Credit Value of t he available credit for Cloud account Account log Log of t he Cloud account event s ...

Страница 33: ...nly cont ain numbers and let t ers wit hout accent s Current password When changing t he password t he current old password must be ent ered Password New password for t he given account The password can be up t o 15 charact ers long and may consist of alphanumeric charact ers and t he following special charact ers _ Confirm password Ent er t he password again Privileges administrator full access U...

Страница 34: ...alog t o ent er t he paramet ers of a new user account Save changes or Create User Saves t he changes Only an administrator or a user wit h the manage users privilege may change t he passwords of other users Note User based account can be used for access to NETIO Mobile2 App ...

Страница 35: ...he device is connect ed t o Connect ed or disconnect ed from Disconnect ed t he local net work Network Name of t he Wi Fi network t o which t he device is connect ed In parent heses t here is an indicat ion of whet her or not t he communicat ion is encrypt ed secure and of signal st rengt h Network Scan From t he menu select a network t o connect t o Press Scan t o have PowerCable search for Wi Fi...

Страница 36: ...on from a DHCP server If your net work does not use DHCP set t he paramet ers st at ically Set static IP address Manual configurat ion of net work paramet ers Select t his opt ion if your net work does not have a DHCP server IP address Choose an unused IP address in your net work s address range Net mask Set t he net work mask according t o your net work s address range Default gateway Address of ...

Страница 37: ...enerat ed from t he Device name unsupport ed charact ers are replaced Save Changes Saves t he changes Caution After changing the network configuration it may be necessary to re discover the PowerCable at its new address The discovery procedure is described in section 3 2 Detecting and configuring t he IP address ...

Страница 38: ...NTP server in your net work use e g tik cesnet cz Set time manually Select if you do not wish t o use a NTP server Date Current dat e and t ime on t he PowerCable s clock Can be modified if necessary Synchronize with this computer Check t his box t o copy t he current dat e and t ime from your comput er t o PowerCable s int ernal clock Timezone Set t he t ime zone t o govern the t ime set t ings S...

Страница 39: ...f t he inst alled firmware version Model Model designat ion Revision Revision number Firmware Package Click Browse t o select a firmware file t o inst all Then click Inst all Firmware t o st art t he inst allat ion Firmware files are available at https www netio products com en powercable xxx firmware Where to find right fw Go to the product page on our website link below select your product and s...

Страница 40: ...g from the correct version and follow the prescribed procedure Downgrade to a lower firmware version may cause the device to reset to factory defaults This will disconnect the device from your WiFi network For this reason we strongly discourage from downgrading the firmware remotely without physical access to the device Before downgrading the firmware always consider if it is really necessary and ...

Страница 41: ...igure above PowerCable 70 under the PowerCable Modbus logo in t he t op left corner CAUTION This value is NOT propagat ed int o t he host name paramet er in t he Net work Configurat ion sect ion HTTP port Current ht t p port If t he port number is different from 80 it has t o be specified in t he web browser aft er t he PowerCable IP address e g 192 168 0 99 888 Enable Periodic device restart Enab...

Страница 42: ...faults Reset s PowerCable t o fact ory default s Follow sect ion 3 1 t o make t he device operat ional again Export and import device configuration Can be used t o back up and rest ore device configurat ion Do not modify t he export ed file Export configurat ion shows a confirmat ion dialog for export ing t he device configurat ion and downloading it t o your comput er Browse opens a dialog t o se...

Страница 43: ...st recent events only and is cleared when t he device is restarted Sources types of log entries System Event generat ed by the system itself e g WiFi reconnect WebApi Event related to a request from the web interface e g User logged in XML M2M XML protocol JSON M2M JSON protocol M2M URL M2M URL API protocol Modbus M2M Modbus TCP protocol MQTT M2M MQTT protocol SNMP M2M SNMP protocol Web server Web...

Страница 44: ...44 7 PowerCable REST 101x 7 1 Overview Only one protocol can be active ...

Страница 45: ... may also fill in t he username and password for t his mode Enable READ WRITE Enables Read Write access for monit oring reading values and writ ing out put cont rol You may also fill in t he username and password for t his mode Username Username for t he respect ive access mode Read Only ReadWrit e Note t his is unrelat ed t o t he username for accessing t he NETIO 4x web administ rat ion int erfa...

Страница 46: ...ml file http PowerCableIP netio xml e g htt p 192 168 120 75 netio xml Example of the netio xml file xml version 1 0 encoding utf 8 set Root xmlns set http www netio products com XMLSchema NETIO xsd Agent Model 101x Model DeviceName PowerCable 6C DeviceName OemID 5 OemID VendorID 0 VendorID Version 2 0 12 Version XmlVer 2 0 XmlVer SerialNumber 24 A4 2C 38 D4 6C SerialNumber Uptime 6879 Uptime Time...

Страница 47: ... XML Schema XSD to download the xsd schema file The Upload XML file to the device button opens t he following dialog for testing Host URL of the xml file Port port number used by the XML API protocol Username and Password Username and password configured for t he XML API protocol in the READ WRITE section Request 1 2 3 select xml file s with commands to perform Send file send t he selected file s ...

Страница 48: ...ebsite and see the following document XML description of NETIO M2M API int erface PDF For more information and a practical demonstration of using the XML protocol with PowerCable smart sockets see the following Application Note AN20 XML HTTP s protocol to control NETIO smart power sockets 110 230V ...

Страница 49: ...for monit oring You may also fill in t he username and password for t his mode Enable READ WRITE Enables Read Write access for monit oring and out put cont rol You may also fill in t he username and password for t his mode Username Username for t he respect ive access mode Read Only ReadWrit e Not e t his is unrelat ed t o t he username for accessing t he PowerCable web administ rat ion When left ...

Страница 50: ...e and password you will receive a j son file with t he PowerCable current state URL for downloading uploading the netio j son file http PowerCableIP netio json e g htt p 192 168 120 75 netio j son Example of the netio j son file Agent Model 101x DeviceName PowerCable 6C MAC 24 A4 2C 38 D4 6C JSONVer 2 0 Time 1970 01 01T14 42 06 01 00 Uptime 6126 Version 2 0 12 OemID 5 VendorID 0 NumOutputs 1 Globa...

Страница 51: ...sed by the JSON protocol Username and Password username and password configured for t he JSON protocol in the READ WRITE section Request 1 2 3 select json file s with commands to perform Send file send t he selected file s Response response to the submitted command Close closes the dialog window Figure 39 Upload JSON f ile dialog For more information about the M2M JSON API visit the Support Downlo...

Страница 52: ... information and a practical demonstration of using the JSON protocol with PowerCable smart sockets see the following Application Note AN21 JSON HTTP S protocol to control NETIO 110 230V power sockets 3x REST API ...

Страница 53: ...e Indicat es t he port where t he device current ly list ens for M2M URL API commands Enable READ WRITE Enables READ WRITE access Password Password t o aut hent icat e HTTP GET communicat ion pass at t ribut e in t he request Save Changes Saves t he changes When the URL API is enabled other M2M protocols are disabled After clicking Save changes you will be asked to confirm t he deactivation of the...

Страница 54: ... under Test URL API This opens a new browser t ab and invokes the following HTTP GET request http PowerCableIP netio cgi pass Password output1 4 e g htt p 192 168 120 75 netio cgi pass netio output1 4 For more information about the M2M URL API visit the Support Download section of our website and see the following document URL API description of NETIO M2M API int erface PDF ...

Страница 55: ...ormation and a practical demonstration of using the URL API protocol with PowerCable smart sockets see the following Application Note AN19 URL API http GET protocol to control NETIO 4x power sockets out lets 110 230V ...

Страница 56: ...Locat ion Community READ Also called t he communit y st ring in SNMP Similar t o a username password combinat ion Needed for reading informat ion from PowerCable over SNMP We recommend t o use pure ASCII charact ers t hat is t o avoid accent ed and special charact ers such as and so on if possible Community WRITE Also called t he communit y st ring in SNMP Similar t o a username password combinat ...

Страница 57: ... 6 1 4 1 47952 1 1 1 2 1 0 STRING output_1 Based on user defined name netioOut putStat e 1 0 1 3 6 1 4 1 47952 1 1 1 3 1 0 INTEGER off 0 on 1 netioOut putStat eString 1 0 1 3 6 1 4 1 47952 1 1 1 4 1 0 STRING off on netioOut putLoad 1 0 1 3 6 1 4 1 47952 1 1 1 25 1 0 INTEGER 24 W netioOut put Energy 1 0 1 3 6 1 4 1 47952 1 1 1 26 1 0 INTEGER 13 Wh netioOut put EnergyStart 1 0 1 3 6 1 4 1 47952 1 1 ...

Страница 58: ...lue Action netioOut putAction 1 0 1 3 6 1 4 1 47952 1 1 1 5 1 0 INTEGER i 0 1 2 3 4 5 Turn OFF Turn ON Short OFF delay restart Short ON delay Toggle invert the state No change For more information about the M2M SNMP API visit the Support Download section of our website and see the following document SNMP API description of NETIO M2M API interface PDF Note There are differences compare to descripti...

Страница 59: ...59 8 PowerCable Modbus 101x 8 1 Overview Only one protocol can be active ...

Страница 60: ...ed However t o be sure we recommend using port numbers above 1024 Last access IP Read only value indicat ing t he IP address from which t he last Modbus TCP command was received The Refresh butt on updat es t his value Enable IP filter To improve securit y t he IP filt er can be used t o specify a range of IP addresses from which Modbus TCP commands are accept ed Commands from addresses out side o...

Страница 61: ...6 104 uInt16 Set action to 4th output 0x06 201 uInt16 Set Short delay of 1st output s 10 0x06 202 uInt16 Set Short delay of 2nd output s 10 0x06 203 uInt16 Set Short delay of 3rd output s 10 0x06 204 uInt16 Set Short delay of 4th output s 10 0x04 0 uInt16 Power grid frequency Hz 100 0x04 1 uInt16 Voltage V 10 RMS 0x04 2 uInt16 TruePowerFactor 1000 0x04 100 uInt16 All outputs current mA 0x04 101 uI...

Страница 62: ...tput energy counter 2 lower bytes Wh 0x04 308 uInt16 4th output energy counter 2 upper bytes Wh 0x04 309 uInt16 4th output energy counter 2 lower bytes Wh For more information about the M2M Modbus TCP protocol visit the Support Download section of our website and see t he following document Modbus TCP description of NETIO M2M API interface PDF ...

Страница 63: ...e information and a practical demonstration of using the Modbus TCP protocol with PowerCable smart sockets see the following Applicat ion Note AN27 Modbus TCP with NETIO 4x Cont rol and measure LAN power sockets ...

Страница 64: ...s via M2M Telnet API for monit oring You may also fill in t he username and password for t his mode Enable READ WRITE Enables Read Write access for monit oring and out put cont rol You may also fill in t he username and password for t his mode Username Username for t he respect ive access mode Read Only ReadWrit e Not e t his is unrelat ed t o t he username for accessing t he PowerCable web admini...

Страница 65: ... username and password by t he equvalent at t ribut es defined in t he Telnet prot ocol configuration Figure 42 password Example log in with username net io and password passwd login netio passwd quit Log out and t erminat e Telnet connect ion noop Keep t he Telnet connect ion alive for the next 60 seconds No operat ion port list Ret urns st at e of out put port list 250 1 output is ON port out pu...

Страница 66: ...ameter Action 0 Turn OFF 1 Turn OFF 2 Short OFF delay rest art 3 Short ON delay 4 Toggle invert t he st ate 5 No change Command examples Switch power output 1 to ON port 1 1 Switch power output 1 to OFF port 1 0 Toggle power output 1 port 1 4 ...

Страница 67: ...d is not valid 505 FORBIDDEN An at tempt t o make an act ion wit h not sufficient permission i e cont rol out put wit h read only user t ry t o monit or out put st ate wit h non logged user where ReadOnly user is password protected etc 510 OUT OF RANGE Specified value is not valid i e t rying to cont rol port 4 on device which has only 1 socket For more information about the Telnet protocol visit ...

Страница 68: ...al demonstration of using the Modbus TCP protocol with PowerCable smart sockets see the following Applicat ion Note AN10 Telnet control of electrical power sockets M2M API KSHELL 8 4 M2M API Protocol SNMP See the description in section 7 5 ...

Страница 69: ...69 9 PowerCable MQTT 101x 9 1 Overview Only one protocol can be active ...

Страница 70: ... MQTT flex funct ions in t he syst em kernel MQTT flex Config Text area for entering the MQTT flex configuration Save Changes Saves t he changes PowerCable MQTT 101x uses j son to define t he MQTT flex struct ure MQTT flex Config Both subscribe and publish topics can be defined Publish t opics may include actions t hat initiate a transmission ...

Страница 71: ...UTS 1 ACTION action payload topic netio DEVICE_NAME output 1 delay qos 0 target OUTPUTS 1 DELAY action payload publish topic netio DEVICE_NAME output 1 voltage qos 0 retain false payload OUTPUTS 1 VOLTAGE V events type delta source OUTPUTS 1 VOLTAGE delta 40 type timer period 3600 topic netio DEVICE_NAME output 1 state qos 0 retain true payload OUTPUTS 1 STATE events type change source OUTPUTS 1 S...

Страница 72: ...cribe and publish sections and its possibilities expand over t he time You will find details and examples at our online resource center https wiki netio product s com index php title MQTT flex For more information and a practical demonstration of using the MQTT protocol with PowerCable smart sockets see the following Application Note AN40 Getting started with PowerCable MQTT flex via HiveMQ MQTT b...

Страница 73: ...f t he t arget ht tp htt ps t o specify t he prot ocol Target URL Port Username Password Example ht t ps username password t est example com 80 push Push Period Period for t he aut omat ic sending of dat a Push in seconds Auto Push delta Dat a will be immediat ely sent Push if a measured value exceeds t his limit Paramet er at t his t ime only Current Value limit value for t he select ed paramet e...

Страница 74: ...ress using HTTP s depending on t he configured push period For more information about the M2M HTTP s Push API visit the Support Download section of our website and see the following document HTTP s Push XML JSON description of NETIO M2M API int erface PDF 9 4 M2M API Protocol SNMP See the description in section 7 5 ...

Страница 75: ...10 1 Overview PowerCable OEM DevKit is ideal for use by developers to test functionalities of selected M2M protocols with own system It supports all available M2M protokols according to previous chapters Only one protocol can be active ...

Страница 76: ...ou CE declaration of conformity You can also declare it by your own based on our measurement protocols c Black customization Similar to Green customization but NETIO products a s will be hidden as device manufact ure from t he device label Defined product name will be listed on the website bottom black label wit hout NETIO as manufact ure and on the paper box All CE certification items stay as pre...

Страница 77: ...301 489 1 V2 2 0 EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 References to the relevant harmonized standards used or references to the other technical specifications in relation to which conformity is declared Art icle 3 1 a Health and safet y Art icle 3 1 b Elect romagnet ic compat ibilit y Art icle 3 2 Effect ive use of radio spect rum Additional information Test Report No EZÚ 700026 01 06...

Страница 78: ...230V 16A 1 0 ZVS Yes PowerBOX 3PG 1 UK 3 230V 16A 1 0 ZVS Yes PowerCable Modbus 101E Int FR 1 1 230V 16A 1 1 Yes ZCS Yes PowerCable Modbus 101F Int DE 1 1 230V 16A 1 1 Yes ZCS Yes PowerCable Modbus 101J Int CH 1 1 230V 10A 1 1 Yes ZCS Yes PowerCable Modbus 101G Int UK 1 1 230V 13A 1 1 Yes ZCS Yes PowerCable Modbus 101S Int C13 1 1 110 230V 10A 1 1 Yes ZCS Yes PowerCable IQRF 901E Yes FR 1 1 230V 1...

Страница 79: ...TT MQTT flex PowerPDU 4C Yes Yes Yes v1 v3 PowerPDU 4PS planed v1 PowerDIN 4PZ planed v1 PowerBox 3Px E F G planed v1 PowerCable Modbus 101x planed v1 PowerCable REST 101x planed v1 PowerCable MQTT 101x planed v1 PowerCable IQRF 901x NETIO 4 DE Yes Yes Yes v1 v3 NETIO 4 FR Yes Yes Yes v1 v3 NETIO 4All DE Yes Yes Yes v1 v3 NETIO 4All FR Yes Yes Yes v1 v3 ...