background image

Using the SG-6005xl Genlock Multistandard SPG/Audio Generator 

KRAMER: SIMPLE CREATIVE TECHNOLOGY

 

10 

Menu Item 

Submenu  

Default Value 

 

 

 FACTORY RESET 

Press ENTER to reset the 

GENLOCK parameters 

 

 

 

 GENLOCK MODE 

 

 HV only, HV and SC 

HV only 

 

 

 GENLOCK TIMING HORIZONTAL 

 

 from -31968ns to 

+31968ns (in 37ns steps)

1

  

 

 

 GENLOCK TIMING VERTICAL 

 

 from -625 line to +625 line  0 

 

 

 GENLOCK EXTRA V SHIFT 

 

 -1 frame, 0 frame, +1 

frame 

0 frame 

 

 

 GENLOCK SC PHASE SHIFT 

 

 from -185

°

 to +185

°

 

 

 

 NON-GENLOCK or HVmode 

SCHphase 

 

 from -64

°

 to +63

°

 

TEST 1 PROGRAMMING 

 

 TEST 2 PROGRAMMING   

ADDRESS OF machine 

 

 First, Second 

First 

7.2  Locking the Front Panel 

To prevent changing the settings accidentally or tampering with the unit via the 
front panel buttons, lock your 

SG-6005xl

. Unlocking releases the protection 

mechanism. 

To lock the SG-6005xl: 

 

Press the LOCK button for more than three seconds, until the LOCK button 
lights 
The front panel is locked. Pressing a button will have no effect other than 
causing the LOCK button to flash

1

To unlock the SG-6005xl: 

 

 

Press the lit LOCK button for more than three seconds, until the LOCK 
button no longer lights 
The front panel unlocks 

7.3 

Remotely Operating via RS-232  

You can remotely operate the 

SG-6005xl

 via RS-232 using a device such as a PC.   

To connect a PC to the SG-6005xl

 

unit using the Null-modem adapter 

provided with the machine (recommended): 

 

Connect the RS-232 9-pin D-sub rear panel port on the 

SG-6005xl

 unit to 

the Null-modem adapter and connect the Null-modem adapter with a 9-wire 
flat cable to the RS-232 9-pin D-sub port on your PC 

To connect a PC to the SG-6005xl

 

unit without using a Null-modem adapter: 

 

Connect the RS-232 9-pin D-sub port on your PC to the RS-232 9-pin D-sub 
rear panel port on the Master 

SG-6005xl

 unit, as illustrated in 

Figure 3

 

                                                       

 

1 Warning that you need to unlock to regain control via the front panel 

Summary of Contents for SG-6005XL

Page 1: ...Kramer Electronics Ltd USER MANUAL Model SG 6005xl Genlock Multistandard SPG Audio Generator...

Page 2: ...ck Multistandard SPG Audio Generator 8 7 1 Operating the SG 6005xl Genlock Multistandard SPG Audio Generator 8 7 2 Locking the Front Panel 10 7 3 Remotely Operating via RS 232 10 8 Technical Specifica...

Page 3: ...ollowing items SG 6005xl Genlock Multistandard SPG Audio Generator Power cord rack ears and Null modem adapter Windows based Kramer control software3 This user manual4 2 Getting Started We recommend t...

Page 4: ...Getting Started KRAMER SIMPLE CREATIVE TECHNOLOGY 2...

Page 5: ...nlock the SPG to an external composite video source via its looping input with selectable termination The SG 6005xl is housed in a 19 1U rack mountable enclosure and is fed from a 100 240 VAC universa...

Page 6: ...Defining the SG 6005xl Genlock Multistandard SPG Audio Generator KRAMER SIMPLE CREATIVE TECHNOLOGY 4 Figure 1 SG 6005xl Front and Rear Panel...

Page 7: ...hine 12 LOOP BNC Connector Connect to an additional machine to loop the genlocking source 13 TERM Button When looping release the TERM button When not looping terminate the line by pressing the button...

Page 8: ...Installing the SG 6005xl in a Rack KRAMER SIMPLE CREATIVE TECHNOLOGY 6 5 Installing the SG 6005xl in a Rack This section describes what to do before installing in a rack and how to rack mount...

Page 9: ...ample in Figure 2 1 Connect the VIDEO OUTPUT BNC connectors to up to 10 composite video acceptors2 OUTPUT 1 to a non linear editor for example OUTPUT 6 to a studio camera OUTPUT 10 to an input on the...

Page 10: ...r connector to the mains electricity 1 7 Using the SG 6005xl Genlock Multistandard SPG Audio Generator This section describes how to Operate the SG 6005xl see Section 7 1 Use front PANEL LOCK button s...

Page 11: ...SILENT ACTIVE SILENT DIGITAL 1 L LEVEL 5 31dBFS to 0dBFS 31dBFS DIGITAL 1 L CHANNEL 5 SILENT ACTIVE SILENT DIGITAL 2 R LEVEL 6 31dBFS to 0dBFS 31dBFS DIGITAL 2 R CHANNEL6 SILENT ACTIVE SILENT DIGITAL...

Page 12: ...r more than three seconds until the LOCK button lights The front panel is locked Pressing a button will have no effect other than causing the LOCK button to flash1 To unlock the SG 6005xl Press the li...

Page 13: ...n 2 XLR connectors 12dBu max 1 unbalanced stereo analog audio on 2 RCA connectors 6dBu max 2 AES EBU digital audio on XLR connectors 0dBFS max 2 AES 75 AES 3id digital audio on BNC connectors 0dBFS ma...

Page 14: ...er lightning orotheractsofnature ii Product modification orfailureto followinstructions supplied with theproduct iii Repairorattemptedrepairby anyonenot authorized byKramer iv Anyshipment oftheproduct...

Page 15: ...REV 2 For the latest information on our products and a list of Kramer distributors visit www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and...

Reviews: