background image

 

RK-6PS - Mounting the Devices on the Rack Adapter 

 

 

Figure 2: RK-6PS Rack Adapter 

– Underside 

5.1 

Mounting devices with no Underside Screw Holes 

Some Kramer devices do not have screw holes on the underside that correspond 

exactly to the holes on the 

RK-6PS

. These devices (for example, the 

FC-7501

 (a 

half-19") or the 

VA-50P

 

(a 6.5” unit)) are connected via the screw holes located on 

the sides of the 

RK-6PS

To mount the devices on the 

RK-6PS

 as illustrated in 

Figure 3

 and 

Figure 4

  

(

FC-7501

 and the 

VA-50P

 respectively), do the following: 

1.  Unscrew the two M3x5 screws from the side panel of the device (for example, 

the Kramer 

FC-7501

 or the

 VA-50P

), which will be attached to the side panel 

of the 

RK-6PS

2.  Place the unit on the rack (for example, the Kramer 

VP-5xl 

or the

  

VA-50P

), adjacent to the inner side panel of the 

RK-6PS

3.  Insert the two M3x8 screws (supplied with the unit) through the holes on the 

side panel of the 

RK-6PS

 that fit the holes on the side panel of the unit (as 

illustrated in 

Figure 3

 and 

Figure 4

). 

4.  Tighten the screws. 

Summary of Contents for RK-6PS

Page 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL RK 6PS Rack Adapter with Power Supplies P N 2900 300466 Rev 1...

Page 2: ......

Page 3: ......

Page 4: ...he RK PS1 12 7 Technical Specifications 17 Figures Figure 1 RK 6PS Rack Adapter 4 Figure 2 RK 6PS Rack Adapter Underside 9 Figure 3 Mounting a half 19 Device via Screws on the RK 6PS Side Panel 10 Fig...

Page 5: ...ROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9...

Page 6: ...k into tight coils Avoid interference from neighboring electrical appliances that may adversely influence signal quality Position your Kramer RK 6PS away from moisture excessive sunlight and dust This...

Page 7: ...wer supply units 1 2 19 1U units for example two VP 5xl units see Section 4 1 1 1 4 19 1U units for example four FC 31xl units or two FC 31xl units with one VP 5xl unit see Section 4 1 1 1 8 19 1U uni...

Page 8: ...mple the Kramer VP 31 One 1 4 19 1U unit for example the Kramer MultiTOOLS 907xl Two 1 8 19 1U units for example two Kramer MultiTOOLS FC 50 Figure 1 RK 6PS Rack Adapter You can order additional blank...

Page 9: ...erent combinations of products Mounting Kramer Products on the RK 6PS measured in inches For example 2 PIP 4 or 2 FC 7501 1 PIP 4 1 907xl 1 102xl 1 PIP 4 1 907xl 1 PS 1DVI 1 PT 1PS 1 FC 7501 2 PS 1DVI...

Page 10: ...to close the gap between the units see Section 4 1 3 1 VM 30AV Use one long and one short blank panel to close the gap between the units see Section 4 1 3 4 1 3 Using Blank Panels Different types of...

Page 11: ...gether with blanks Mounting Kramer Products with Blank Panels on the RK 6PS For example 1 PIP 4 1 1 2 19 blank panel 1 1 2 19 blank panel 1 1 4 19 blank panel 1 FC 31xl 1 PIP 4 1 FC 31xl 1 1 8 19 blan...

Page 12: ...for example the Kramer 907xl 2 Hold both the 907xl and the RK 6PS with your hands and turn them upside down 3 Insert and the appropriate amount of screws through the holes on the RK 6PS that correspo...

Page 13: ...vices on the RK 6PS as illustrated in Figure 3 and Figure 4 FC 7501 and the VA 50P respectively do the following 1 Unscrew the two M3x5 screws from the side panel of the device for example the Kramer...

Page 14: ...10 RK 6PS Mounting the Devices on the Rack Adapter Figure 3 Mounting a half 19 Device via Screws on the RK 6PS Side Panel Figure 4 Mounting a 6 5 Device via Screws on the RK 6PS Side Panel...

Page 15: ...connect a blank panel to the RK 6PS to cover any empty spaces as the example in Figure 5 illustrates One 1 2U 19 blank panel is supplied with the RK 6PS package otherwise you need to purchase a blank...

Page 16: ...wing power supplies ordered separately Power Supply for Power Specs 5V Power Supply Type 12V Power Supply The USA PS 504 US 60 0001895 5V 4A With a 75cm C14 power cord cable 100 120V AC 50 60Hz PS 120...

Page 17: ...S1 onto the RK 6PS To adjust the RK PS1 to the selected power supply Insert the power supply into the RK PS1 Adjust the height of the RK PS1 by partially releasing and then tightening the two nuts on...

Page 18: ...he RK PS1 onto the RK 6PS 1 Insert the RK PS1 and tighten with two M3x5 screws supplied with the unit to the RK 6PS Figure 6 Attaching the RK PS1 2 Insert the power supply and partially release the tw...

Page 19: ...Setting the Adjustment Plate 4 Connect the power supply cable according to the specific instructions if required in the user manual of the Kramer product Figure 9 Connecting the power cable to the Dev...

Page 20: ...K 6PS Figure 10 Connecting Additional RK PS1 Adapters 6 Connect the power cables to each of the devices Figure 11 Connecting the Power Supply to the other Devices 7 Connect the C14 cable cord from eac...

Page 21: ...S 60 0001895 5V 4A With a 75cm C14 power cord cable 100 120V AC 50 60Hz PS 1202 US 60 000195 12V 2A With a 75cm C14 power cord cable 100 120V AC 50 60Hz Europe PS 504 EU 60 0001890 5V 4A With a 75cm C...

Page 22: ......

Page 23: ...sit our Web site where updates to this user manual may be found We welcome your questions comments and feedback Web site www kramerelectronics com E mail info kramerel com SAFETY WARNING Disconnect th...

Reviews: