background image

 

 

Step 3:  Install KC-BRAINware-50 

To rack mount the machine, attach both rack ears 
(by removing the screws from each side of the 
machine and replacing those screws through the 
rack ears) or place the machine on a table.  

 

 

  Ensure that the environment (e.g., maximum ambient temperature & 

air flow) is compatible for the device. 

  Avoid uneven mechanical loading. 

  Appropriate consideration of equipment nameplate ratings should be 

used for avoiding overloading of the circuits. 

  Reliable earthing of rack-mounted equipment should be maintained. 

Step 4:  Connect the inputs and outputs 

Always switch OFF the power on each device before connecting it to your 

KC-BRAINware-50

. For best results, we 

recommend that you always use Kramer high-performance cables to connect AV equipment to 

KC-BRAINware-50

 

Connecting Keyboard, Mouse, and Display are optional. SSH has been enabled by default and is the recommended process for 

configuring 

KC-BRAINware-50

 

 

For optimum range and performance use the recommended Kramer cables available at 

www.kramerav.com/product/KC-BRAINware-50

. 

Using third-party cables may cause damage! 

Step 5:  Connect the power 

Connect the power cord to 

KC-BRAINware-50

 and plug it into the mains electricity. 

 

Safety Instructions (Se

www.kramerav.com

 for updated safety information)

 

 

Caution: 

  For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual. 

  There are no operator serviceable parts inside the unit. 

Warning: 

  Use only the power cord that is supplied with the unit.  

  Disconnect the power and unplug the unit from the wall before installing.

  

  Do not open the unit. High voltages can cause electrical shock! Servicing by qualified personnel only. 

  To ensure continuous risk protection, replace fuses only according to the rating specified on the product label which located on the bottom of the unit.

 

 

Step 6:  Set up KC-BRAINware-50 

 

Knowledge of IP networking is required to perform the following procedure. Inaccurate IP calculation could damage your IP 

network when you start 

KC-BRAINware-50

.  

 

1.  Connect to 

KC-BRAINware-50

 using one of the following two methods: 

 

Connect via SSH kramer@IPofHardware and use the password: KC_Brainware.  

 

Connect a mouse, keyboard, and monitor directly to 

KC-BRAINware-50

2.  Identify the gateway and subnet of the network to which 

KC-BRAINware-50

 is connected. 

 

You may need to contact your IT manager to obtain this information.  

 

3.  Connect to the 

KC-BRAINware-50

 terminal and run the following command to configure a part of the subnet as the 

range of addresses for all 50 Brains: 

kramer config set docker.brain.network.ip_range=<your starting address>/26 

for example: 

kramer config set docker.brain.network.ip_range=192.168.110.192/26

 

4.  Run the following commands to update all Brains:  

kramer docker update brain 

After completion of the update, all Brains start and are available on the customer network. 

 

  

  

  

  

  