background image

Kramer Electronics, Ltd. 

 
 

 

 

 
 

 
 
 
 
 
 
 

 

 
 

 

 

USER MANUAL 

 

 

Model: 

FC-7402 

SDI to Analog Converter 

 

 

Summary of Contents for FC-7402

Page 1: ...Kramer Electronics Ltd USER MANUAL Model FC 7402 SDI to Analog Converter...

Page 2: ...6 Technical Specifications 9 7 Communication Protocol 10 Figures Figure 1 FC 7402 SDI to Analog Converter 2 Figure 2 Connecting an FC 7402 SDI to Analog Converter 4 Figure 3 Connecting a PC without u...

Page 3: ...original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resolution cables3 3 Overview The high quality FC 7402 is a m...

Page 4: ...r friendly Windows based program that can modify parameters such as hue contrast brightness sharpness and color Lets you store recall up to 10 setups in non volatile memory To achieve the best perform...

Page 5: ...achine is turned on 15 PANEL LOCK LED Illuminates when the panel is locked blinks after pressing a button when the panel is locked 16 PANEL LOCK Button Engages disengages the front panel buttons Table...

Page 6: ...osite video monitor 3 Connect the Y C OUTPUT 4p connector to an s Video acceptor for example an s Video monitor 4 Connect the component video OUTPUT BNC connectors Y G B Y B and R Y R to either a YUV...

Page 7: ...to the Null modem adapter and connect the Null modem adapter with a 9 wire flat cable to the RS 232 DB9 port on your PC To connect a PC to the FC 7402 unit without using a Null modem adapter Connect...

Page 8: ...ndard see Table 4 8 BAR ON for machine to operate as a 75 color bar generator based on the clock of the SDI input Table 4 Dipswitch Settings AUTO PAL and NTSC AUTO PAL NTSC FC 7402 Output Standard OFF...

Page 9: ...o 2 X OVRSMPL To adjust oversampling to x2 do the following 1 Set DIP 4 OFF and remove the power cord 2 Open the FC 7402 unit and move Jumper JMP1 to the left see Figure 4 3 Close the FC 7402 unit set...

Page 10: ...l by one unit The 7 segment display shows the new level Note To increase or decrease the current level rapidly press and hold down the button or button continuously2 To end the rapid adjustment releas...

Page 11: ...ideo 1Vpp 75 on a BNC connector 1 YC 1Vpp 75 Luma 0 3Vpp 75 Chroma on a 4p connector 1 component RGB Y R Y B Y 1V 0 7V 0 7V 75 on BNC connectors 1 SDI reclocked SMPTE 259M ITU R BT 601 CCIR 601 75 on...

Page 12: ...ATA D7 and the EXTENDED DATA E7 are in the fourth byte Terminology TO PC is the DESTINATION BIT I4 I0 is the INSTRUCTION D7 D0 is the DATA E7 E0 is the EXTENDED DATA The destination bit TO PC is 0 whe...

Page 13: ...s instruction then if valid the selected video parameter is set and the machine replies by sending the same 4 bytes except for the Destination Bit back to the PC When the user changes video parameters...

Page 14: ...e set for a fixed standard the FC 7402 will reply by sending the code for the fixed standard INSTRUCTION 16dec ERROR If the machine receives an invalid instruction it replies by sending this error cod...

Page 15: ...riginal dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address...

Page 16: ...E mail info kramerel com P N 2900 007402 REV 1 For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com Updates to this user manual may...

Reviews: