Kramer FC-4001 User Manual Download Page 11

Technical Specifications 

 

 

9

7  Technical Specifications 

Table 6 includes the technical specifications: 

Table 6: Technical Specifications

1

 of the FC-4001 Format Converter / TBC 

INPUTS: 

1 composite video - 1 Vpp / 75  on a BNC connector 
1 YC - 1 Vpp/75  (Y), 0.3Vpp/75  on a 4p connector 
1 component - Y/R-Y/B-Y (1Vpp/0.7Vpp/0.7Vpp) /75  (or RGB/S) on BNC 

connectors 

1 SDI: SMPTE-259M, ITU-R BT.601 on a BNC connector 
1 SYNC (Genlock): Looped 75  / Hi-Z on BNC connectors 

OUTPUTS: 

1 composite video on a BNC connector 1 Vpp/75  
1 YC video on 2 BNC connectors: Y 1 Vpp/75 , and C 0.3Vpp/75  
1 component or RGB/S video on BNC connectors 1Vpp/0.7Vpp/0.7Vpp/75  
1 SYNC on a BNC connector 
2 SDI: SMPTE-259M, ITU-R BT.601 on BNC connectors 

VIDEO STANDARDS: 

PAL-B/D/G/H/I/M/N, NTSC-3.58/4.43, SECAM 

DIGITAL RESOLUTION: 

10 bits 

BANDWIDTH (-3dB): 

0.5dB to 5MHz, Fully Loaded 

DIFF. GAIN: 

1% 

DIFF. PHASE: 

1 Deg. 

K-FACTOR: 

1% 

S/N RATIO: 

63dB 

LUMA NON-LINEARITY: 

1% 

CHROMA / LUMA DELAY:  1ns 
CONTROLS: 

Front-panel and RS-232; SCH phase, SYNC phase, H shift, freeze, panel 

lock 

POWER SOURCE: 

100-240VAC, 50/60Hz, 14VA 

DIMENSIONS: 

19 inch (W), 7 inch (D), 1U (H) rack mountable 

WEIGHT: 

2.6 kg. (5.7 lbs.) approx. 

ACCESSORIES: 

Power cord, Null-modem Adapter 

8  Communication Protocol 

RS-232 communication between the 

FC-4001

 and the PC is performed using 

this protocol (VER-0.1), which uses four bytes of information, and data is at 

9600 baud, no parity, 8 data bits and 1 stop bit. 
The controller and the machine should be connected via a null-modem 

connection, that is, if using a DB-9 port, connect PIN 5 of the PC to PIN 5 of 

the machine, cross PINs 2 and 3, that is, connect PIN 2 of the PC to PIN 3 of 

the machine, and connect PIN 3 of the PC to PIN 2 of the machine. On the PC 

side, short PINs 4 and 6, and short PINs 1, 7 and 8. This protocol 

complements Kramer’s “Protocol 2000” (Kramer’s switcher protocol), that is, 

the two protocols can co-exist without disturbing one another (according to 

Protocol 2000’s definitions, the 

FC-4001

 would be machine number 24). 

                                                        

1 Specifications are subject to change without notice 

Summary of Contents for FC-4001

Page 1: ...Kramer Electronics Ltd USER MANUAL Model FC 4001 Format Converter TBC...

Page 2: ...rter TBC 3 Figure 2 Connecting a PC without using a Null modem Adapter 7 Figure 3 Connecting the FC 4001 Format Converter TBC 8 Tables Table 1 Front Panel FC 4001 Format Converter TBC 4 Table 2 Rear P...

Page 3: ...ou Unpack the equipment carefully and save the original box and packaging materials for possible future shipment Review the contents of this user manual Use Kramer high performance high resolution cab...

Page 4: ...anel buttons for input selection CV Y C YUV RGB S and SDI Genlock freeze and panel lock Coarse trimmers and fine trimmers for adjusting the sync phase and the horizontal to subcarrier phase SCH Contro...

Page 5: ...Your FC 4001 Format Converter TBC 3 Figure 1 FC 4001 Format Converter TBC...

Page 6: ...o source 18 Y C 4p Connector Connects to the s Video Y C source 19 G Y BNC Connector 20 R R Y BNC Connector 21 B B Y BNC Connector 22 SYNC BNC Connector Connects to the RGB connect all 3 connectors R...

Page 7: ...Refer to the appropriate nameplate ratings for information For example for fuse replacement see the value printed on the product label 5 The machine is earthed grounded in a reliable way and is connec...

Page 8: ...rs to the FC 4001 the Two SDI OUTPUT BNC connectors to two serial digital video acceptors for example two displays SDI Display 1 and SDI Display 2 Four BNC OUTPUT connectors CV R R Y G Y and C B B Y a...

Page 9: ...our PC to the RS 232 DB9 rear panel port on the FC 4001 unit as Figure 2 illustrates Figure 2 Connecting a PC without using a Null modem Adapter 6 2 Dipswitch Settings The FC 4001 dipswitch settings a...

Page 10: ...IP 5 Dipswitch Set as follows 4 AGC ON for enabling automatic gain control OFF for disabling automatic gain control 5 75 Bar Generator ON for enabling 75 Bar Generator OFF for disabling 75 Bar Generat...

Page 11: ...A LUMA DELAY 1ns CONTROLS Front panel and RS 232 SCH phase SYNC phase H shift freeze panel lock POWER SOURCE 100 240VAC 50 60Hz 14VA DIMENSIONS 19 inch W 7 inch D 1U H rack mountable WEIGHT 2 6 kg 5 7...

Page 12: ...the machine or 1 when sending from the machine to the PC Table 8 Instruction Set INSTRUCTION I5 I4 I3 I2 I1 I0 0 Reset 0 0 0 0 0 0 16 Error 0 1 0 0 0 0 32 Read front panel switch data 1 0 0 0 0 0 33...

Page 13: ...version number before the decimal point and EXTENDED DATA is the value following the decimal point For example for version 3 4 the machine replies with DATA 03 hex and EXTENDED DATA 04 hex FRONT PANEL...

Page 14: ...is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name...

Page 15: ...or the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions commen...