42
Kramer Protocol 3000
11.3
Kramer Protocol 3000
– Detailed Commands
This section lists the detailed commands applicable to the FC-21ETH, FC-22ETH,
FC-24ETH.
Command -
#
Command Type - System-mandatory
Command Name
Permission
Transparency
Set:
#
End User
Public
Get:
-
-
-
Description
Syntax
Set:
Protocol handshaking
#
␍
Get:
-
-
Response
~nn@
␠
OK
␍␊
Parameters
Response triggers
Notes
Use to validate the Protocol 3000 connection and get the machine number
Command -
BUILD-DATE?
Command Type - System-mandatory
Command Name
Permission
Transparency
Set:
-
-
-
Get:
BUILD-DATE?
End User
Public
Description
Syntax
Set:
Read device build date
#
BUILD-DATE
␍
Get:
-
-
Response
~nn@
BUILD-DATE
␠
date
␠
time
␍␊
Parameters
date
-
Format: YYYY/MM/DD where YYYY = Year, MM = Month, DD = Day
time
-
Format: hh:mm:ss where hh = hours, mm = minutes, ss = seconds
Response triggers
Notes