background image

 

 

Step 4:  Set DIP-switches 

Video Switching Selection 

DIP-switch 1 DIP-switch 2 Video Input Selection 

DIP-switch 1 

DIP-switch 2 

Video Input Selection 

Off (up) 

Off (up) 

Automatic

—Last connected. Where more than one source is 

connected the last one connected has priority 

Off (up) 

On (down) 

Automatic

—Priority selection.  

HDMI 1 

 HDMI 2 

 PC IN (default, high to low priority) 

On (down) 

Off (up) 

Manual 

On (down) 

On (down) 

Manual 

 

Audio Switching Selection 

DIP-switch 3 

DIP-switch 4 

Audio Input Selection 

Off (up) 

Off (up) 

Automatic

—Priority selection. 

Embedded HDMI

™ 

 analog Audio In (high to low priority) 

Off (up) 

On (down) 

Automatic

—Priority selection. 

Analog Audio In 

 embedded HDMI (high to low priority) 

On (down) 

Off (up) 

Embedded HDMI 

On (down) 

On (down) 

Analog Audio In 

The terms HDMI, HDMI High-Definition Multimedia Interface, and the HDMI Logo are trademarks or registered trademarks of HDMI Licensing Administrator, Inc. 

Step 5:  Connect power 

Connect the power cord to 

DIP-20

 and plug it into the mains electricity. 

 

Safety Instructions (Se

www.kramerav.com

 for updated safety information)

 

 

Caution: 

  For products with relay terminals and GPI\O ports, please refer to the permitted rating for an external connection, located next to the terminal or in the User Manual. 

  There are no operator serviceable parts inside the unit. 

Warning: 

  Use only the power cord that is supplied with the unit.  

  Disconnect the power and unplug the unit from the wall before installing.

  

 

Step 6:  Operate DIP-20 

Default IP Parameters 

Parameter 

Values 

Default 

Device Name 

Any alphanumeric string up to 14 chars (can include hyphen, but not at the beginning or end) 

KRAMER_ 

DHCP 

ON/OFF 

OFF 

IP Address 

Any valid IP address 

192.168.1.39  

Mask 

Any valid network mask 

255.255.0.0 

Gateway 

Any valid gateway address 

192.168.0.1 

TCP Port 

0 to 65535 

5000 

UDP Port 

0 to 65535 

50000 

 

Default RS-232 Communication Parameters 

Parameter 

Values 

Baud Rate  

115200 

Data Bits  

Stop Bits  

Parity 

None 

Command Format 

ASCII 

 

Default Web Pages Logon Authentication 

Parameter 

Values 

Name 

Admin 

Password 

Admin 

 

 

You can operate the 

DIP-20

 via the front panel buttons, remote P3000 commands, or by using a Web browser to access the  

built in Web pages.  

 

  