14 Troubleshooting
14.2 Troubleshooting
Fault
identification
Cause
Remedy
–
–
–
–
5
Outgassing
Increase the system pressure.
Reduce the temperature.
–
–
–
–
5
Pulsations too high
Use another feed pump.
Carry out changes to the system.
–
–
–
–
5
Back pressure too low
Increase the back pressure.
–
–
–
–
5
Flow rate fluctuations too high
Ensure a continuous flow rate by taking suitable measures (use of a different pump,
valve, damper, etc.).
-or-
Smoothen the indication. In the process observe the operating instructions of the elec-
tronic equipment.
–
–
3
–
5
Filling amount too low
Use a flowmeter with a suitable size.
Use a flowmeter from a suitable series.
–
–
–
–
5
Strongly deviating operating data
Use a flowmeter from a suitable series.
Adapt the operating data to the flowmeter.
–
–
–
4
5
Sluggishness through deposits
Disassemble the flowmeter and clean it carefully.
–
2
3
–
–
Flow impaired at the system end
Check whether the fluid flows in the system (pump in operation, slide valve opened,
etc.).
Check whether shut-off devices before and after the flowmeter are opened.
–
2
3
–
–
Flowmeter switched to bypass
Switch the flowmeter to through-flow.
Tab. 11: Fault table