10 Operation
10.2 Commissioning
1.
Open the screw plug of the vent hole
1
by a max. of 2 rotations so that air can escape during the
filling process.
2.
Open the suction-side or pressure-side shut-off device and fill the pump via the suction connec-
tion or pressure connection until pumped liquid is emitted at the vent hole
1
.
3.
During the filling process turn the pump shaft or the fan impeller of the motor by hand to speed up
the filling process:
Filling via suction connection: Turn the fan pump shaft in the direction of rotation of the motor.
Filling via pressure connection: Turn the pump shaft against the direction of rotation of the motor.
4.
Retighten the screw plug of the vent hole
1
.
Filling and venting the pump via the vent hole
Personnel qualification:
o
Fitter
Personal protective equipment:
o
Work clothing
o
Face protection
o
Protective gloves
o
Safety boots
WARNING
Risk of injury through emitted pumped liquid.
Pumped liquids can be hot, poisonous, combustible and caustic.
► Wear personal protective clothing during all the work. Ensure face protection.
► Collect any discharging pumped liquid safely and dispose of it in an environmentally compatible
manner in accordance with the applicable local regulations.
Requirement:
ü
Shut-off devices in the suction line and pressure line closed
1.
Open the screw plug of the vent hole
1
by a max. of 2 rotations so that air can escape during the
filling process.
2.
Remove the screw plug of the pressure-side vent hole
3
.
3.
Fill the pump via the pressure-side vent hole
3
, until the pumped liquid is emitted at the vent
hole
1
.
4.
During the filling process turn the pump shaft or fan impeller of the motor by hand to speed up the
filling process:
Filling of the suction chamber: Turn the pump shaft against the direction of rotation of the motor.
Filling of the sealing chamber: Turn the pump shaft in the direction of rotation of the motor. To
speed up filling of the sealing chamber, fill the sealing chamber of the pump via the vent hole
1
,
until pumped liquid is emitted.
5.
Retighten the screw plug of the pressure-side vent hole
3
.
6.
Retighten the screw plug of the vent hole
1
.
10.2.3
Checking the direction of rotation
The direction of rotation is indicated by an arrow on the pump flange. The direction of rotation of the
motor specifies the direction of rotation of the pump. The fan impeller of the motor must rotate in the
same direction in which the arrow for the direction of rotation on the pump flange points.
Notice
Standard direction of rotation: clockwise (viewed from the motor)
Personnel qualification:
o
Fitter
ATTENTION
Dry running can damage pump equipment.
► Ensure that the pump is filled properly.
► Switch the pump on for a maximum of one second and then off again immediately.
1.
Switch on the power supply and then turn it off again immediately.
24
OIC 18en-GB Edition 2020-01
Operating instructions