28
ВЕРТИКАЛЬНАЯ МОРОЗИЛЬНАЯ КАМЕРА
UPRIGHT FREEZER
ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ • USER GUIDE
29
ВЕРТИКАЛЬНАЯ МОРОЗИЛЬНАЯ КАМЕРА
UPRIGHT FREEZER
ИНСТРУКЦИЯ ПО ЭКСПЛУАТАЦИИ • USER GUIDE
5. Disassemble the screws fixed
the bottom-hinge with cross-slot
screwdriver and replace the hinge to
the other side then fix it with screws.
Note: the refrigerator incline angle
less 45°
.
6. Replace the leveler to the other side and adjust it to make sure the cabinet level.
The screws fixed
the bottom-hinge
7. Set the door right position, fix the top-hinge and then the roof cover.
Installation
Space
Requirement
Select a location without direct exposure to sunlight;
Select a location with enough space for the refrigerator doors to open
easily;
Select a location with level (or nearly level) flooring;
Allow sufficient space to install the refrigerator on a flat surface;
Allow clearance to the right, left, back and top when installing. This
Keep at lest 50mm gap at two sides and back.
will help reduce power consumption and keep your energy bills lower.
Install this appliance at a location where the ambient temperature corresponds to the climate class
indicated on the rating plate of the appliance:
Positioning
Climate class
Ambient temperature
SN
N
ST
T
o
o
+10 C to +32 C
o
o
+16 C to +32 C
o
o
+16 C to +38 C
o
o
+16 C to +43 C
The appliance should be installed well away from sources of heat such as radiators, boilers, direct sunlight
etc. Ensure that air can circulate freely around the back of the cabinet. To ensure best performance, if the
appliance is positioned below an overhanging wall unit, the minimum distance between the top of the cabi-
net and the wall unit must be at least 100 mm. Ideally, however, the appliance should not be positioned
below overhanging wall units. Accurate leveling is ensured by one or more adjustable feet at the base of
the cabinet.
Location
Warning!
It must be possible to disconnect the appliance from the mains power supply; the plug must
therefore be easily accessible after installation.
Before plugging in, ensure that the voltage and frequency shown on the rating plate correspond to your
domestic power supply. The appliance must be earthed. The power supply cable plug is provided with a
contact for this purpose. If the domestic power supply socket is not earthed, connect the appliance to a
separate earth in compliance with current regulations, consulting a qualified electrician.
The manufacturer declines all responsibility if the above safety precautions are not observed.
This appliance complies with the E.E.C. Directives.
Electrical connection
7
Installation
Space Requirement
• Keep enough space of door open.
• Keep at least 50mm gap at two sides.
Levelling the unit
• To do this adjust the two levelling feet
at front of the unit.
• If the unit is not level, the doors and
magnetic seal alignments will not be
covered properly.