SAFETY DEVICES
OPERATION
27
INFRARED TEMPERATURE CONTROLLER
This is a non contacting system to check fluid coupling
temperature. It is reliable and easy-mounting.
It has 2 adjustable thresholds with a logical alarm on the former,
and a relay alarm on the latter.
The proximity sensor must be positioned near the fluid coupling
outer impeller or cover, according to one of the layouts shown in
Fig. 9.
It is adviced to place it in A or C positions, as the air flow
generated by the fluid coupling during rotation helps to remove
possible dirt particles that may lay on the sensor lens.
The distance between the sensor and the fluid coupling must be
about 15-20 mm (cooling fins do not disturb the correct operation
of the same sensor).
To avoid the bright surface of the fluid coupling reflecting light and
producing an incorrect temperature reading, it is necessary to
paint the surface which is directly facing the sensor a flat black
colour (a stripe of 6-7 cm is sufficient).
The sensor cable has a standard length of 90 cm. In the case
where, a longer cable is required, use one that is plaited and
shielded as per type “K” thermocouples.
C
B
A
9
FIG.
AT
2
1
78.50
15-20 max
Pag27
78.50
AT
2
1
C
B
A
9
FIG.
DISPLAY
Pag27
120
25
48
Ch.23.7
PG11
DIN
1.5
6.4
5.6
34
5.6
SENSOR
Temperature range
0 ÷ 200 °C
Ambient temperature
-18 ÷ 70 °C
Accuracy
0.0001 °C
Dimensions
32.5 x 20 mm
Standard wire length •
0.9 m
Body
ABS
Protection
IP 65
CONTROLLER
Power supply
85…264 Vac / 48…63 Hz
Relay output OP1
NO (2A – 250V)
Logical output OP2
Not insulated
(5Vdc, ±10%, 30 mA max)
AL1 alarm (display)
Logic (OP2)
AL2 alarm (display)
Relay (OP1) (NO, 2A / 250Vac)
Pins protection
IP 20
Body protection
IP 30
Display
IP 65
protection
Dimensions
1/32 DIN – 48x24x120 mm
Weight
100 gr
Fig. 9
•
TO BE MADE LONGER WITH TWISTED AND SHIELDED WIRES FOR TYPE K THERMOCOUPLES (NOT SUPPLIED)
SENSOR
Thread
DIN PG 11
Max panel thickness 20 mm