FLUID COUPLING SELECTION
8
MOTOR
FRAME
143T
22.275
(0.875)
145T
182T
28.575
(1.125)
184T
213T
34.925
(1.375)
215T
254
41.275
(1.625)
256T
284T
47.625
(1.875)
284TS
41.275
(1.625)
286T
47.625
(1.825)
286TS
41.275
(1.625)
324T
53.975
(2.125)
324TS
47.625
(1.875)
53.975
(2.125
60.325
(2.375)
73.025
(2.875)
85.725
(3.375)
326T
364T
365T
404T
405T
444T
445T
SHAFT DIA.
mm (inch)
1800 rpm
HP
1
6 K
1.5 - 2
3
7 K
5
7.5
8 K
10
15
9 K
20
25
11 K
-
-
30
12 K
-
-
40
12 K
-
-
13 K
15 K
17 K
19 K
50
60
75
100
125
150
200-250
COUPLING
1200 rpm
HP
0.75
7 K
1
1.5
8 K
2
3
9 K
5
7.5
11 K
10
15
12 K
-
-
20
13 K
-
-
25
13 K
-
-
15 K
17 K
19 K
21 K
30
40
50
60
75
100
125
COUPLING
900 rpm
HP
0.5
7 K
8 K
0.75
1
9 K
1.5
2
11 K
3
5
12 K
7.5
10
13 K
-
-
15
15 K
-
-
20
17 K
-
-
17 K
19 K
21 K
25
30
40
50
60
75
100
COUPLING
3600 rpm
HP
1.5
6 K
2
3
5
7.5
7 K
10 - 15
15 - 20
8K
20 - 25
-
-
30
9K
-
-
40
9K
-
-
50
9K
-
-
COUPLING
NON - STANDARD
MOTOR
400
600
21 K
24 K
958
27 K
1360
29 K
270
24 K
400
598
27 K
29 K
1088
34 K
1350
D 34 K
150
24 K
220
350
27 K
29 K
600
34 K
1000
D 34 K
SELECTION TABLE
Fluid couplings for standard electric motor
max
max
max
General note: The fluid coupling size is tied to the motor shaft dimensions
(1) Special version, 24 hours/day service
(1)
Summary of Contents for CCKSD-QD
Page 2: ......