Digital clamp meter

ENGLISH

ENG

ENG

See the full

instruction manual:

Introduction

WARNING

Make sure to read and follow all safety procedures to avoid electric shock and/or injury.

The KPS-PA420 is a safe, reliable, yet small handheld 3 ½ digit digital clamp meter. Capable 

of  measuring  AC  current,  AC/DC  voltage,  resistance,  diode’s  forward  voltage  drop,  and 

continuity, it’s ideal for both home users and professionals.

Safety Instructions

The KPS-PA420 meets EN61010-1 safety requirements for electrical testing instruments and 

handheld digital multimeters. It’s designed to comply with EN61010-1 with a CAT III 600V 

safety rating and pollution degree of 2.

•  All safety guidelines outlined should be followed otherwise the protection provided by the 

instrument may be impaired.

•  Warning symbols in the manual alert users of potential dangerous situations.

•  Precautions are to prevent the user from damaging the instrument or the test object.

Precautions

To avoid possible electric shock, personal injury or damage to the meter, please observe 

the following:

1. Before using the meter, check the meter for damage during transport.

2. Check the test leads for damage to the insulation or wires before use.

3. Ensure the meter works properly by testing a known voltage first. If not working properl ,

have the meter serviced before using.

4. Never exceed the protection limit values indicated in the specifications for each range of

measurement.

5. Always use caution when making voltage measurements above 60V DC or 30V AC rms.

6. Make sure to use the correct input jack, function and range when measuring.

7. Do not place the meter in any environment with dust, explosive gas or vapor.

8. Always keep fingers behind the probe barriers

9. Connect the common test lead first, then the hot lead. Disconnect in reverse orde .

10. Turn off power and discharge capacitors before measuring resistance, diodes or continuity.

11. Failure to follow safety guidelines may prevent the meter ’s built in protection from working 

properly.

12. To avoid damage or incorrect readings, check for AC voltage present before making DC 

voltage measurements.

13. Do not use the meter with the battery cover not securely in place.

14. When the   symbol appears, replace the batteries to avoid incorrect readings.

15. Before opening the case, always disconnect test leads from all energized circuits.

16. Only use the test leads provided with the meter. Replace only with similar leads with 

      matching specifications

17. Do not touch input jacks during measurement to avoid electric shock.

18. Before switching functions, remove test leads from a circuit.

Maintenance

WARNING

Protection impairment if used in a manner not specified by the manufacture .

General maintenance

This  section  provides  basic  maintenance  principies,  including  cleaning  and  battery 

replacement.  Do  not  attempt  to  do  any  repair  or  calibration  to  the  meter  unless  you  are 

experienced maintenance personnel.

WARNING

Remove test leads from meter before opening the battery cover to avoid damage or injury.

Use a damp cloth anda small amount of detergent to clean the meter regularly. Do not use 

abrasives or chemical solvents. Dirty or wet input jacks can affect readings.

To clean the input jacks:

1. Turn off meter and remove test leads

2. Wipe any debris off input jacks

3. Use a cotton swab with a cleaner/lubricant (i.e. WD-40) to clean jacks.

4. Use a new swab for each jack to prevent cross contamination.

Replacing the batteries

WARNING

To avoid electric shock, make sure that the test leads have been clearly move away from the

circuit under measurement before opening the battery cover of the meter.

WARNING

Do  not  mix  old  and  new  batteries.  Do  not  mix  alkaline,  standard  (carbon-  zinc),  or 

rechargeable (ni-cad, ni-mh, etc) batteries.

•  If the sign    appears, it means that the batteries should be replaced.

•  Loosen the fixing screw of the battery cover and remove it 

•  Replace the exhausted batteries with new ones.

•  Put the battery cover back and fix it again to its origin form

Note:

Do not reverse the polarity of the batteries.

Replacing Test Leads

Replace test leads if leads become damaged or worn.

WARNING

Use meet EN 61010-031 standard, rated CAT III 600V, or better test leads.

Accessories

Summary instruction manual  

1 piece

Test leads   

1 pair

Case  

1 piece

AAA batteries (1.5V)    

3 pieces

ENGLISH

MGL EUMAN,

 S.L.

 

Parque Empresarial de Argame,

C/Picu Castiellu, Parcelas i-1 a i-

4

E-33163 Argame, Morcín

Asturias, España, (Spain)

APAC: 

MGL GLOBAL SOLUTIONS LTD

[email protected]

Flat 4-1, 4/F, No. 35, Section 3 Minquan 

East Road. Taipei, Taiwan.

Tel: +886 2-2508-0877

EMEA: 

MGL EUMAN S.L.

[email protected]

Parque Empresarial Argame, 33163 

Morcín. Asturias, Spain.

Tel: +34 985-08-18-70

AMERICAS: 

MGL AMERICA, LLC.

[email protected]  

US East Coast:

 2810 Coliseum Centre 

Drive, Ste. 100. Charlotte, North Carolina, 

28217 USA

Tel: +1 833 533-5899

US West Coast:

 760 Challenger Street. 

Brea, California 92821 USA

Tel: +1 310-728-6220

www.mgl-intl.com

Reviews: