7. If pilot goes out, repeat steps 3 through 6. This heater has a safety interlock

system. Wait one(1) minute before relighting pilot.

8.  When the  pilot  is lit,  turn  gas control  knob  to ON.  Turn  thermostat control

knob counterclockwise              to desired heating level. The main burner
should light. Set control knob to heat level between 7 and 1.

CAUTION : Do not try to adjust heating levels by using the manual shutoff valve.

TURNING OFF GAS TO HEATER

Shutting Off Heater 

Turn control knob clockwise               to the OFF position.

Shutting Off Burner Only (Pilot stays lit)

Turn control knob clockwise               to the PILOT position.

THERMOSTAT CONTROL OPERATION

Thermostat has a sensing bulb and a temperature control knob. The thermostat used
on this heater senses the room temperature and turns the burner on and off. 
At times the room may exceed the set temperature.If so, the burner will shut off. 
The burner will cycle back on when room temperature drops below the set
temperature.

Pilot Burner

Ignitor Electrode

Thermocouple

1

2

3

4

5

6

7

PILOT

NO

OFF

IGN

Summary of Contents for KWN185

Page 1: ...gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified ins...

Page 2: ...al Safety Instructions Product Identification Local Codes National Fuel Code Unpacking the Heater Package Product Features Fresh Air for Combustion and Ventilation Installation Gas Requirements Leak C...

Page 3: ...ocated so that you know where to shut off the gas to the heater If you smell gas your installer has not done a proper job of checking leaks If the connections are not perfectly seated or tightened you...

Page 4: ...eater and to replace any part of the control system and any gas control which has been under water Keep appliance area clear and free from combustible materials gasoline and other flammable vapors and...

Page 5: ...for proper operation If not poor fuel combustion could result Read the following instructions to insure proper fresh air for this and other fuel burning appliances in your home ADEQUATE COMBUSTION VE...

Page 6: ...LP Propane and make sure the marking on the appliance rating plate agrees with that of the supply gas The rating plate is located on the side of the heater which indicates the type of gas that heater...

Page 7: ...other gases CAUTION If you install the heater in a home garage Heater must be at least 18 inches above floor Locate heater where moving vehicle will not hit it Preparing For Installation Select a loc...

Page 8: ...o wall as shown in Fig 4 4 Insert mounting screws through each bracket and into wall anchors 5 Tighten screws until mounting bracket is firmly fastened to wall Installing Bottom Mounting Screws 1 Loca...

Page 9: ...0 Inches Sides 13 Inches Top 36 Inches Floor 2 Inches NOTICE Maintain the minimum clearances shown in Figure 1 but you can provide greater clearances from floor ceiling and adjoining wall 2 After moun...

Page 10: ...ine pressure is higher heater gas pressure regulator damage could occur CAUTION Use only new black iron or steel pipe and internally tinned copper tubing may be used in certain areas Check your local...

Page 11: ...LP units check with a full cylinder CAUTION NEVER LEAK TEST WITH AN OPEN FLAME PRESSURE TESTING GAS SUPPLY PIPING SYSTEM The appliance and its individual shutoff valve must be disconnected from the g...

Page 12: ...and safety valve the burner must be lit See operating Instructions Check the rest of the connections for leaks 7 Turn off the heater See Instructions NOTE Never use an open flame to check for a leak A...

Page 13: ...urn clockwise to the OFF position 4 Wait five minutes to clear any gas Then smell for gas including near the floor If you smell gas follow the safety information on the front page If you don t smell g...

Page 14: ...e TURNING OFF GAS TO HEATER Shutting Off Heater Turn control knob clockwise to the OFF position Shutting Off Burner Only Pilot stays lit Turn control knob clockwise to the PILOT position THERMOSTAT CO...

Page 15: ...PILOT position 4 With control knob pressed in strike match hold match to pilot until pilot lights 5 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control k...

Page 16: ...off position Make sure the heater is cool BURNER AND ODS PILOT CLEANING Clean the exterior with soft bristle brush vacuum cleaner pressurized air Never use a wooden toothpick as it may break off and c...

Page 17: ...ple Problem could be result of one or both of the following Partially clogged ODS pilot orifice Low gas pressure 4 Thermocouple damaged 5 Thermocouple connection loose at gas control valve 6 Gas contr...

Page 18: ...efective 1 Foreign matter in gas or on burner ports 2 Heater burning vapors from paint impurities in air 3 Gas leaks See front page Warnings 1 Not enough fresh air is available 2 Low gas pressure 3 OD...

Page 19: ...W C SIZE OF HEATER H W D WEIGHT OPTIONAL ACCESSORIES Purchase these heater accessories from your local distributors dealers If they can not furnish these items call World Marketing of America Inc 1 81...

Page 20: ...Page 19 PARTS LIST...

Page 21: ...C Connector D NAT Wall Mounting Bracket L R Wall Mounting Screw Screw A Screw B PART NO FOR KW N313 P314 KW N185 P186 REF 2A0054 20 0142 1A0038 REF 2A0047 REF 3A0025 20 1022 GV31B1A2ADH0 REF 4A0051 2...

Page 22: ...A PARTICULAR PURPOSE THE REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES IN NO EVENT WILL WORLD MARKETING OF AMERICA BE LIABLE FOR INCIDENTAL OR CONSEQUENTIA...

Page 23: ...ck is not as bright as another your heater is probably due for a good cleaning Replacement of the thermocouple or pilot assembly is generally not needed Review Heater Maintenance on page 15 of the own...

Reviews: