Kozy-World KGH 301 Owner'S Operation And Installation Manual Download Page 17

1 7

ILLUSTRATED  PARTS

BREAKDOWN

KGH301

Summary of Contents for KGH 301

Page 1: ...is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufact...

Page 2: ...fic and away from furniture and draperies Surface of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain h...

Page 3: ...CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel Gas code ANSZ223 1 also known as NFPA 54 Available from American Na...

Page 4: ...entilation air by one of the methods described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows m...

Page 5: ...l burning appliances in the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not...

Page 6: ...union l test gauge connection l sediment trap l tee joint l pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purc...

Page 7: ...racket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall These two holes are 16 inches apart from their centers Attach mounting bracket to wall only in one of two wa...

Page 8: ...screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Placing Heater on Mounting Bracket 1 Locate two horizontal slots on back panel of heate...

Page 9: ...must be up stream from heater see Figure 12 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA desi...

Page 10: ...g show a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 K Pa 1 Clo...

Page 11: ...ut any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information on the side of heater If you don t smell gas g o t o t h e n e x t s t e p 5 Push in and...

Page 12: ...le about two inches from where the pilot flame comes out of the pilot assembly see Figure 21 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if comp...

Page 13: ...ged 5 Gas regulator setting is not correct 6 Control knob not in PILOT position 1 Control knob is not fully pressed in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not ful...

Page 14: ...g while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Mainte...

Page 15: ...ndows POSSIBLE CAUSE 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak See Warning Statement at top of page 1 Not enough fresh air is available 2 Low...

Page 16: ...odel and serial numbers of your heater l how heater was malfunctioning l type of gas used propane LP or natural gas l purchase date Usually we will ask you to return the defective part to the factory...

Page 17: ...1 7 ILLUSTRATED PARTS BREAKDOWN KGH301...

Page 18: ...PARTS AVAILABLE NOT SHOWN DESCRIPTION Cabinet Assembly Lower Front Panel Assembly Reflector Unit Steel Wind Shield Grill Guard Assembly Middle Panel Ignitor Assembly Self Tapping Screw Control Valve I...

Reviews: