Kozy-World KGH 301 Owner'S Operation And Installation Manual Download Page 1

OWNER

S OPERATION AND INSTALLATION MANUAL

B L U E   F L A M E   V E N T - F R E E

NATURAL    GAS

  G A R A G E     H E AT E R

      WA R N I N G :    I f     t h e     i n f o rm a t i o n     i n  this
manual  is  not  followed  exactly, a     f i r e     o r
e x p l o s i o n     m a y     r e s u l t  causing  property
damage,  personal injury,  or  loss  of  life.

    WARNING:   This  is  an  unvented gas-fired
heater.  It  uses  air  (oxygen) f r o m     t h e     r o o m
i n     w h i c h     i t     i s  installed.  Provisions  for
adequate combustion  and  ventilation  air  must
b e     p r o v i d e d .     R e f e r     t o     A i r     F o r  Combus-
tion  and  Ventilation section on  page  4  of  this
manual.

        WA R N I N G :     I m p r o p e r       i n s t a l l a t i o n ,
adjustment, alteration, service  or  mainte-
nance can  cause  injury  or  property  damage.
Refer  to  this  manual  for  correct  installation  and
operational  procedures.  For  assistance  or
additional  information  consult  a  qualified
installer,  service  agency,  or   gas  supplier.

This  appliance  may  be  installed  in  an  aftermar-
ket*  permanently  located, manufactured
(mobile) home, where  not  prohibited  by  local
codes.
This appliance  is  only  for  use  with  the  type  of
gas  indicated  on  the  rating  plate. This
appliance  is  not  convertible  for  use  with  other
gases.

*Aftermarket: Completion  of  sale, not  for  purpose  of
resale,  from  the  manufacturer.

Do  not  store,  or  use  gasoline  or  other  flammable
vapors  and  liquids  in  the  vicinity  of  this  or  any
other  appliance.
WHAT  TO  DO  IF  YOU  SMELL  GAS

Do  not  try  to  light  any  appliance.

Do   not   touch   any   electrical   switch;  do  not

       use  any  phone  in   your  building.

Immediately   call   your  gas  supplier  from  a

       neighbor’s   phone.   Follow   the   gas  supplier’s
       instructions.

If   you   cannot  reach  your  gas  supplier, call

       the  fire  department.
Installation  and  service  must  be  performed  by  a
q u a l i f i e d     i n s t a l l e r ,   s e r v i c e     a g e n c y    o r     g a s
supplier.

Table  of  Contents

Important Safety Information.................................2

Product  Features.....................................................3

Proper Ventilation & Fresh Air.................................4

.

Installation................................................................6

Operating Your Heater............................................11

Cleaning & Maintenance........................................12

Trouble  Shooting....................................................13

Specifications..........................................................16

Parts List...................................................................18

World Marketing of America, Inc.
P.O. Box 192, Rt. 22 West
Mill Creek, PA 17060

KOZY WORLD PHONE NUMBER: (814) 643-2299

http://www.worldmkting.com

Kozy-World

                 

KGH 301

Save  this  manual  for  future  reference.

Summary of Contents for KGH 301

Page 1: ...is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufact...

Page 2: ...fic and away from furniture and draperies Surface of heater becomes very hot when running heater Keep children and adults away from hot surface to avoid burns or clothing ignition Heater will remain h...

Page 3: ...CODES Install and use heater with care Follow all local codes In the absence of local codes use the latest edition of National Fuel Gas code ANSZ223 1 also known as NFPA 54 Available from American Na...

Page 4: ...entilation air by one of the methods described in the National Fuel Gas Code ANS Z223 1 Section 5 3 or applicable local codes Unusually Tight Construction The air that leaks around doors and windows m...

Page 5: ...l burning appliances in the space Vent free heater Btu Hr Gas water heater Btu Hr Gas furnace Btu Hr Vented gas heater Btu Hr Gas Fireplace logs Btu Hr Other gas appliances Btu Hr Total Btu Hr Do not...

Page 6: ...union l test gauge connection l sediment trap l tee joint l pipe wrench A CSA AGA design certified equip ment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purc...

Page 7: ...racket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall These two holes are 16 inches apart from their centers Attach mounting bracket to wall only in one of two wa...

Page 8: ...screws through bracket and into wall anchors 7 Tighten screws until mounting bracket is firmly fastened to wall Placing Heater on Mounting Bracket 1 Locate two horizontal slots on back panel of heate...

Page 9: ...must be up stream from heater see Figure 12 A CSA AGA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA AGA desi...

Page 10: ...g show a leak 5 Correct all leaks at once 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 K Pa 1 Clo...

Page 11: ...ut any gas Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information on the side of heater If you don t smell gas g o t o t h e n e x t s t e p 5 Push in and...

Page 12: ...le about two inches from where the pilot flame comes out of the pilot assembly see Figure 21 With the unit off lightly blow air through the air inlet hole You may blow through a drinking straw if comp...

Page 13: ...ged 5 Gas regulator setting is not correct 6 Control knob not in PILOT position 1 Control knob is not fully pressed in 2 Control knob is not pressed in long enough 3 Equipment shutoff valve is not ful...

Page 14: ...g while heating or contracting while cooling 1 When heated the vapors from furniture polish wax carpet cleaners etc turn into white powder residue REMEDY 1 Clean burner orifice see Cleaning and Mainte...

Page 15: ...ndows POSSIBLE CAUSE 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANT statement above 2 Gas leak See Warning Statement at top of page 1 Not enough fresh air is available 2 Low...

Page 16: ...odel and serial numbers of your heater l how heater was malfunctioning l type of gas used propane LP or natural gas l purchase date Usually we will ask you to return the defective part to the factory...

Page 17: ...1 7 ILLUSTRATED PARTS BREAKDOWN KGH301...