TROUBLESHOOTING

ODS/pilot  lights  but  flame is continu-
ous igniting and the main burner
couldn

t be lit.

1. Thermocouple    connection    loose  at

control  board

2.  Pilot  flame  not  touching thermocouple

which  allows thermocouple  to  cool,
causing  pilot  flame  to  go  out.  This
problem  could  be  caused  by  one or
both of the following

      A)   Low  gas  pressure
      B)  Dirty  or  partially  clogged ODS/  pilot
3.  Thermocouple  damaged
4.  Control  valve  damaged

1.  Hand tighten the connectors.

2.   A) Contact local  gas company.
      B)  Clean ODS/pilot (

see Cleaning and

Maintenance

, page 13) or replace ODS/

pilot  assembly

3.    Replace  thermocouple
4.    Replace  control  valve

Burner does not light after  ODS/pilot   is
lit

1.    Burner orifice clogged

2.   Inlet  gas  pressure  is  too  low
3.   Burner  orifice  diameter  is  too  small
4.   Thermocouple  leads  disconnected or

improperly connected

5.  Burners  will  not  come  in remote posi-

tion

1.  C lean   b urner  (

s ee   C le an in g  an d

Maintenance

,  page  13)  or    replace

burner orifice.

2.  Contact local gas company
3.   Replace  burner  orifice
4.   Reconnect    leads (

see   wiring  diagram

)

5.  Replace  battery  in  transmitter  and

receiver

REMEDY

     WARNING: Make sure that power
is turn off before proceeding....

       WARNING:

  

Turn off  and let cool

before servicing. Only a  qualified  ser-
vice  person  should service and re-
pair  fireplace.

       CAUTION: Never use a wire,
needle, or similar object  to clean
ODS/pilot. This  can  damage  ODS/
pilot  unit.

W hen  pressing  the  button  of  ignitor
button  is  pressed, there  is   spark at
ODS/pilot but  no  ignition

OBSERVED  PROBLEM

POSSIBLE CAUSE

1.   Gas   supply   turned   off   or   equipment

shut off  valve closed

2.  Air in gas lines when installed.

3.   Depleted gas supply
4.  ODS/pilot  is  clogged

5.   Gas regulator setting is not correct
6.  Pilot electrode position is not correct
7. Wire is not correct or loosen
8 Gas valve is damage

1.  Turn on gas  supply  or  open  equipment

shutoff valve

2.  Press ON/OFF button again until air is

removed

3.  Contact  local gas company
4    Clean  ODS/pilot  (see  Cleaning  and

Maintenance, page 13 ) or replace ODS/
pilot  assembly

5.  Replace  gas  regulator
6.  Replace Pilot
7.  Check the wine and make wine correct.
8.  Replace gas valve

No spark when press in ignition button

1.  No power to heater
2.  No battery in transmitter or battery

isn

t correctly assembly

3.  The Control Knob is not on ELEC-

TRIC position

4.  System halt

1. Check the electric power
2. Place or replace the battery

3. Set Control Knob to ELECTRIC position

4.  Place the control knob of manual over-

ride on OFF position for at least 1 minute,
then turn to ELECTRIC position

NOTE:  BEFORE YOU SWITCH TO 

ELECTRIC

 CONTROL LEVEL FROM MANUAL CONTROL,

YOU NEED TO TURN THE KNOB TO 

OFF

 LEVEL FIRST AND WAIT FOR ONE MINUTE,

THEN TURN THE KNOB TO 

ELECTRIC

.

IN CASE OF 

ELECTRONIC

 CONTROL LEVEL DOES NOT WORK, PLEASE TURN THE

CONTROL KNOB COUNTERCLOCKWISE TO 

OFF

 LEVEL AND WAIT FOR ONE MINUTE.

Summary of Contents for GFN2515R

Page 1: ...where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion...

Page 2: ...Information Warnings 3 Air for Combustion and Ventilation 5 Installation 7 Operating heater 10 Cleaning Maintenance 13 Trouble Shooting 15 Specifications 16 Replacement Parts 17 Parts List 18 Install...

Page 3: ...nd other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convert ible for use with other gases 2 Do not place Pro...

Page 4: ...eck for any shipping damage If fireplace or logs are damaged promptly inform dealer where you bought the fireplace from PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion S...

Page 5: ...ing if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining ro...

Page 6: ...Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequa...

Page 7: ...ating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air A...

Page 8: ...wells This gas is commonly known as wellhead gas CAUTION Only use a new black iron or steel pipe Internally tinned cop per tubing may be used in certain areas Check your local codes Use pipe of 1 2 d...

Page 9: ...pply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings...

Page 10: ...se this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has...

Page 11: ...ess or to change to the correct minute s then press CLOCK button again time setting is finished 3 When in operation point the remote transmitter to the remote receiver on the burner in a maximum dista...

Page 12: ...ot smell gas go to the next step 6 Push in gas control slightly and turn counterclockwise to PILOT and depress for five 5 seconds NOTE The first time that the heater is operated after connecting the g...

Page 13: ...tterns often PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pattern Figure 18 shows an incorrect pilot flame pattern The incorrect pi lot flame is not touching the thermocouple This will ca...

Page 14: ...heater before each u se H ave h eat er insp ec t ed yearly by a qualified service person H e a t e r m a y n e e d m o r e f r e q u e n t c l e a n i n g d u e t o excessive lint from carpeting bedd...

Page 15: ...eedle or similar object to clean ODS pilot This can damage ODS pilot unit W hen pressing the button of ignitor button is pressed there is spark at ODS pilot but no ignition OBSERVED PROBLEM POSSIBLECA...

Page 16: ...intenance page 13 2 Replace gas regulator Slight smoke or odor during initial operation 1 Residues from manufacturing processes 2 Not enough air 3 Gas regulator defective 1 Problem will stop after a f...

Page 17: ...unctioning l Type of gas used propane LP or natural gas l Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this...

Page 18: ...18 ILLUSTRATED PARTS BREAKDOWN GFN2515R GFP2516R...

Page 19: ...jector NG 1 08 EL025 01 Injector LP 1 09 EB37000R Outlet Tube Assembly 1 1 10 NRV81F1 3 Regulator NG 1 11 NRV81F1 8 Regulator LP 1 12 EB36000R Inlet Tube Assembly 1 1 13 EB38000R ODS Inlet Tube Assemb...

Page 20: ...20 ILLUSTRATED PARTS BREAKDOWN GFN2515R GFP2516R EL250RHB C EN250RHB C...

Page 21: ...8 EL019 06RB Back Panel 1 1 9 EL004 06 Regulator Bracket 1 1 10 EL010 01C Upper Decorating Frame 1 1 11 EL011 01 Upper Decorating Wire 1 1 12 EL002 03 01 Upper Mid Louver 1 1 1 1 13 EL006 06 Side Refl...

Page 22: ...e upper part of log 4 into the pin on the left side of log 1 Place the lower part on the flat roof at the left side of log 3 Figure 3 l Insert the pinhole on the upper side of log 5 into the pin on th...

Reviews: