Kozy-World GFN2515R Owner'S Operation And Installation Manual Download Page 1

1

COMPACT  VENT-FREE
FIREPLACE  SYSTEM

OWNER

S OPERATION AND INSTALLATION MANUAL

Do  not  store  or  use  gasoline  or  other  flam-

mable vapors  and  liquids  in  the  vicinity  of

this  or  any  other  appliance.

WHAT  TO  DO  IF  YOU  SMELL  GAS

Do  not  try  to  light  any  appliance.

Do   not   touch   any   electrical   switch;

do  not use  any  phone  in   your  building.

l

  Immediately    call    your  gas   supplier

from  a neighbor

s   phone.   Follow   the   gas

supplier

s instructions.

If   you   cannot  reach  your  gas  supplier,

call  the  fire  department.

Installation  and  service  must  be  performed

by  a  qualified  installer, service  agency,

or gas  supplier.

        WAR N IN G :  

  I

mpr op e r  in s ta ll a ti on ,

adjustment, alteration, service  or  mainte-

nance can  cause  injury  or  property  damage.

Refer  to  this  manual  for  correct  installation

and operational  procedures.  For  assistance

or  additional  information  consult  a  quali-

fied  installer,  service  agency  or  gas  supplier.

This  appliance   may  be   installed   in  an

aftermarket*,  permanently  located, manufac-

tured (mobile) home, where  not  prohibited

by  local  codes.

This appliance  is  only  for  use  with  the  type

of  gas  indicated  on  the  rating  plate. This

appliance  is  not  convertible  for  use  with

other  gases.

*Aftermarket: Completion  of  sale, not  for  purpose  of
resale,  from  the  manufacturer.

Installer: Please leave these instructions with the

consumer

.

Consumer: Please retain these instructions for

future use.

WATER VAPOR:

A BY-PRODUCT OF UNVENTED ROOM HEATERS

Water vapor is a by-product of gas combustion. An
unvented room heater produces approximately one
(1) ounce (30ml) of water for every 1,000 BTU

s (.3KW

s)

of gas input per hour. Refer to page 4.

    WARNING:

  

 This  is  an  unvented gas-

fired heater.  It  uses  air  (oxygen) f r o m    t h e

r o o m     i n     w h i c h     i t     i s  installed.   Provi-

sions  for  adequate combustion  and  venti-

lation  air  must  b e     p ro v i d e d .     R e fe r     t o

Air     Fo r  Combustion  and  Ventilation sec-

tion on  page 5  of  this  manual.

     WARNING:

  

If  the    information    in

this  manual  is  not  followed  exactly, a

fire     or    e x plosion    ma y    re sult caus-

ing  property  damage,  personal injury,

GFN2515R      GFP2516R

Kozy-World

R

World Marketing of  America, Inc.

P. O. Box 192, Rt.. 22 West

Mill Creek, PA 17060

KW-EL020RBW-0505

KOZY WORLD PHONE NUMBER :(814)643-1775

http://www.worldmkting.com

Summary of Contents for GFN2515R

Page 1: ...where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases Aftermarket Completion...

Page 2: ...Information Warnings 3 Air for Combustion and Ventilation 5 Installation 7 Operating heater 10 Cleaning Maintenance 13 Trouble Shooting 15 Specifications 16 Replacement Parts 17 Parts List 18 Install...

Page 3: ...nd other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convert ible for use with other gases 2 Do not place Pro...

Page 4: ...eck for any shipping damage If fireplace or logs are damaged promptly inform dealer where you bought the fireplace from PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion S...

Page 5: ...ing if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining ro...

Page 6: ...Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequa...

Page 7: ...ating heater where impurities such as tobacco smoke aromatic candles cleaning fluids oil or kerosene lamps etc in the air exist may discolor walls IMPORTANT Vent free heaters add moisture to the air A...

Page 8: ...wells This gas is commonly known as wellhead gas CAUTION Only use a new black iron or steel pipe Internally tinned cop per tubing may be used in certain areas Check your local codes Use pipe of 1 2 d...

Page 9: ...pply mixture of liquid soap and water to gas joints Bubbles forming show a leak 5 Correct all leaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings...

Page 10: ...se this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has...

Page 11: ...ess or to change to the correct minute s then press CLOCK button again time setting is finished 3 When in operation point the remote transmitter to the remote receiver on the burner in a maximum dista...

Page 12: ...ot smell gas go to the next step 6 Push in gas control slightly and turn counterclockwise to PILOT and depress for five 5 seconds NOTE The first time that the heater is operated after connecting the g...

Page 13: ...tterns often PILOT FLAME PATTERN Figure 17 shows a correct pilot flame pattern Figure 18 shows an incorrect pilot flame pattern The incorrect pi lot flame is not touching the thermocouple This will ca...

Page 14: ...heater before each u se H ave h eat er insp ec t ed yearly by a qualified service person H e a t e r m a y n e e d m o r e f r e q u e n t c l e a n i n g d u e t o excessive lint from carpeting bedd...

Page 15: ...eedle or similar object to clean ODS pilot This can damage ODS pilot unit W hen pressing the button of ignitor button is pressed there is spark at ODS pilot but no ignition OBSERVED PROBLEM POSSIBLECA...

Page 16: ...intenance page 13 2 Replace gas regulator Slight smoke or odor during initial operation 1 Residues from manufacturing processes 2 Not enough air 3 Gas regulator defective 1 Problem will stop after a f...

Page 17: ...unctioning l Type of gas used propane LP or natural gas l Purchase date Usually we will ask you to return the defective part to the factory PARTS NOT UNDER WARRANTY Contact authorized dealers of this...

Page 18: ...18 ILLUSTRATED PARTS BREAKDOWN GFN2515R GFP2516R...

Page 19: ...jector NG 1 08 EL025 01 Injector LP 1 09 EB37000R Outlet Tube Assembly 1 1 10 NRV81F1 3 Regulator NG 1 11 NRV81F1 8 Regulator LP 1 12 EB36000R Inlet Tube Assembly 1 1 13 EB38000R ODS Inlet Tube Assemb...

Page 20: ...20 ILLUSTRATED PARTS BREAKDOWN GFN2515R GFP2516R EL250RHB C EN250RHB C...

Page 21: ...8 EL019 06RB Back Panel 1 1 9 EL004 06 Regulator Bracket 1 1 10 EL010 01C Upper Decorating Frame 1 1 11 EL011 01 Upper Decorating Wire 1 1 12 EL002 03 01 Upper Mid Louver 1 1 1 1 13 EL006 06 Side Refl...

Page 22: ...e upper part of log 4 into the pin on the left side of log 1 Place the lower part on the flat roof at the left side of log 3 Figure 3 l Insert the pinhole on the upper side of log 5 into the pin on th...