Kozy-World GFD2915 Manual Download Page 17

 

 
 
(Match Light) 

1.  Remove screen by lifting and pulling forward.  
2.  Follow steps 1 through 7 under MANUAL OPERATING Lighting Instructions. 
3.  With Control Knob in PILOT position, strike match, and hold near pilot. Press in Control Knob; pilot should 

light. 

4.  Keep Control Knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release Control Knob.  
5.  Make sure the fireplace screen is in place before operating fireplace. 

 
 

INSPECTING BURNERS 

1. 

Turn

 

control knob to pilot position 

2. 

Inspect pilot flame and refer to Figure 15 and 16.  

·

 

Figure 15 shows a correct pilot flame pattern.  

·

 

Figure 16 shows an incorrect pilot flame pattern. The  

 

incorrect pilot  flame  is  not  touching the  

 

thermocouple.  This will cause the thermocouple  

 

to cool.  When the thermocouple cools, the heater 

 

 will shut down.   

·

 

If the pilot flame is incorrect, as shown in Figure16.   
Turn heater off (see To Turn Off Gas to Appliance,  
page 16) See troubleshooting, page 19. 

 

BURNER FLAME PATTERN 

·

 

Figure 17 shows a correct burner flame pattern.  

·

 

Figure 18 shows an incorrect burner flame pattern.  
If burner flame is incorrect: 

 

Turn heater off (see To Turn Off Gas to Appliance,  

 

page 16) see Troubleshooting, Page 19.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 MANUAL LIGHTING PROCEDURE 

 

 

Figure 15 - Correct Pilot Flame Pattern 

 

 

Figure 16 - Incorrect Pilot Flame Pattern

 

 

 

Figure 17 - Correct Flame Pattern with Control 

Knob Set to High Flame 

 

 

Figure 18 

 Incorrect Flame Pattern with Control 

Knob Set to High (5) 

17 

Summary of Contents for GFD2915

Page 1: ...heater It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air For Combustion and Ventilation section on page 7...

Page 2: ...y result in a possible fire hazard and will void the warranty PRODUCT SPECIFICATIONS ITEM NO GFD2921 GFD2915 GFDC3029 Input Rating 28 000 BTU Hr 28 000 BTU Hr 28 000 BTU Hr 28 000 BTU Hr Gas Type Natu...

Page 3: ...your guide to safe and proper operation of this heater Make certain you read and understand all warnings Keep this manual for reference It is your guide to safe and proper operation of this heater WAR...

Page 4: ...le See Air for Combustion and Ventilation pages 7 through 9 If heater keeps shutting off see Troubleshooting pages 19 through 21 10 Do not run heater Where flammable liquids or vapors are used or stor...

Page 5: ...itter in the Commonwealth of Massachusetts Sellers of unvented propane or natural gas fired supplemental room heaters shall provide to each purchaser a copy of 527 CMR 30 upon sale of the unit In the...

Page 6: ...An unvented room heater produces approximately one 1 ounce 30ml of water for every 1 000 BTU s 3KW s of gas input per hour Unvented room heaters are recommended as a supplemental heater for a room rat...

Page 7: ...doorless passageways or ventilation grills between them Unusually Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in...

Page 8: ...ng room If the extra space provides an unconfined space remove door to adjoining room or add ventilation grills between rooms See Ventilation Air from Outdoors page 9 b Vent room directly to the outdo...

Page 9: ...ter in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the heater in high traffic ar...

Page 10: ...d INSTALLATION ITEMS NEEDED Before installing heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connectio...

Page 11: ...essible location The equipment shutoff valve is for turning on or shutting off the gas to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going int...

Page 12: ...ate heater between locked positions 3 Rotate and close cover over gas selection valve and reinstall screw 4 Remove hex plug with wrench provided from natural gas inlet of regulator and install into LP...

Page 13: ...to all joints Bubbles forming show a leak Correct all leaks immediately Pressure Testing Heater Gas Connections 1 Open equipment shutoff valve see Figure 11 2 Open gas supply tank valve 3 Make sure co...

Page 14: ...ontact any log If so reposition logs according to the log installation instructions in this manual Flames contacting logs will create soot IMPORTANT Make sure log does not cover any burner ports see F...

Page 15: ...ilding Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department C Use only your hand to push in...

Page 16: ...0 seconds release control knob Note If pilot goes out repeat steps 3 through 8 This heater has a safety interlock system Wait one 1 minute before lighting pilot again 10 Warning Make sure while the in...

Page 17: ...incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down If the pilot fla...

Page 18: ...blow position If using compressed air in a can please follow the directions on the can If you don t follow directions on the can you could damage the pilot assembly 1 Shut off the unit including the...

Page 19: ...phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING Make sure that power is turned off before proceeding WARNING Turn off and let cool...

Page 20: ...meter is too small 3 Inlet gas pressure is too low 1 Burner orifice see Cleaning and maintenance Page 18 or replace burner orifice 2 Replace burner orifice 3 Contact your gas supplier Delayed ignition...

Page 21: ...off when using furniture polish wax carpet cleaner or similar products When ignitor button is pressed in 1 Ignitor is positioned wrong 2 Ignitor electrode is broken 3 Ignitor electrode is not connecte...

Page 22: ...arts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replacement part s call KOZY WORLD PHONE NUMBER 814 643 1775 for referral inf...

Page 23: ...age 22 of this manual KEY NO PART NUMBER DESCRIPTION QUANTITY 1 SIT545 200 T STAT VALVE 1 2 RV83FI 4 9 REGULATOR 1 3 FBB28D01 BURNER ASSEMBLY 1 4 NDD0308x400 ODS 1 5 FBB28D06 ODS INLET TUBE ASSEMBLY 1...

Page 24: ...PARTS LIST GFD2921 GFD2915 This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 22 of this manual 24 13...

Page 25: ...PARTS LIST GFDC3029 This list contains replaceable parts used in your heater When ordering parts follow the instructions listed under Replacement Parts on page 22 of this manual 25 12...

Page 26: ...e 1 Make sure point of the mitered edge of mounting strip touches the corner Use a level to ensure mounting strips are evenly balanced IMPORTANT Failure to balance mounting strips with a level could r...

Page 27: ...g will lock the rear mantel top in position then use 14 screws to secure bracket as show in Figure 5 make sure the front and rear mantel top are in the same level 8 Move the surround back Set surround...

Reviews: