![Kozy-World 602-30 Operation And Installation Manual Download Page 16](http://html1.mh-extra.com/html/kozy-world/602-30/602-30_operation-and-installation-manual_1999831016.webp)
Page 16
Note : The thermostat sensing bulb measures the temperature of air near the
heater cabinet. This may not always agree with room temperature (depending
on housing construction, installation location, room size etc.). Frequent use of
your heater will let you determine your own comfort levels.
MANUAL LIGHTING INSTRUCTIONS
1. Remove lower front panel.
2. Follow steps 1 through 4 as stated under Lighting Instructions.
3. Press and turn control knob counterclockwise to the PILOT position.
4. With control knob pressed in, strike match, hold match to pilot until pilot lights.
5. Keep control knob pressed in for 30 seconds after lighting pilot. After 30
seconds, release control knob.
6. Replace lower front panel.
INSPECTING MAIN BURNER AND PILOT BURNER
Pilot Flame Pattern
The following figures show a correct and incorrect flame patterns. The incorrect
flame is not touching the thermocouple. This will cause a nuisance shut down.
If pilot flame pattern is incorrect as shown above, turn heater off and refer to
troubleshooting guide.
Burner Flame Pattern
This heater allows the view of flames and provides the simulation of a solid fuel
fireplace. The incorrect log position can cause flame impingement, which can
cause soot formation. Propane installations seem to have more of a sooting
problem due to the richness of LP gas.
CORRECT
INCORRECT
Pilot Burner
Thermocouple
Pilot Burner
Thermocouple
Summary of Contents for 602-30
Page 21: ...Page 21 PARTS LIST...