FRAMING 13
3.5 Clearances to Combustibles
Table 3.1, Minimum Appliance Clearances to Combustible Material
From appliance top stand-offs
0”
0mm
From facing material 1” (25mm) stand-off flange
0”
0mm
From appliance back stand-offs
0”
0mm
From appliance corners
1/4”
6mm
From appliance front
36”
914mm
From appliance top to fireplace enclosure top
12”
305mm
Appliance sides to adjacent sidewall
4-1/2”
114mm
Fireplace enclosure floor to 3/4” (19mm) trim
33-1/2”
108mm
Mantel 6” (152mm) deep from fireplace enclosure floor
37”
940mm
Minimum height of fireplace enclosure
42”
1076mm
Minimum width of fireplace enclosure
34-1/2”
876mm
Minimum depth of fireplace enclosure
14”
356mm
14”
(356mm)
½
”
(13mm)
34
½
”
(876mm)
13
1⁄8
”
(334mm)
38
½
”
(978mm)
¼
”
(6mm)
27
¼
”
(692mm)
54
7⁄16
”
(1383mm)
14”
(356mm)
½
”
(13mm)
34
½
”
(876mm)
34
½
”
(876mm)
TYPICAL VERTICAL INSTALLATION
TYPICAL HORIZONTAL INSTALLATION
TYPICAL CORNER INSTALLATION
Figure 3.3, Typical Installation Options