INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
IMPORTANT: If installing a fan, it is easier to complete before the millivolt board is connected to the gas
line. Wiring must be done before enclosing fireplace sides. An electrical box and romex connector are pre-
installed on a removable panel on the right side of fireplace. A receptacle / speed control assembly and (3)
wire nuts are included in the fireplace components packet.
The optional fan kit #TRF-028 includes:
(2) 75 CFM fan with temperature control switch and 4 ft. (1219 mm) fan cord
NOTE: Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly.
Refer local electrical codes for specific requirements.
WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR
PROTECTION AGAINST SHOCK HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A
PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT OR REMOVE THE
GROUNDING PRONG FROM THIS PLUG.
Incoming wiring
110V - 120V
60Hz
110V - 120V
Temperature Switch:
Magnetically attaches to bottom of
firebox.
Speed Control / Receptacle Assembly
Electrical Box
The following components must be removed from the fireplace prior to installation of this fan. Refer to the corresponding pages in this
installation manual for assistance if necessary.
A
.
Upper hood, upper louver & lower grill, if installed. Page 36.
B. Glass assembly. Page 15.
OPTIONAL FAN INSTALLATION (PRC-36 only)
WARNING: MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY
ELECTRICAL LINES.
PAGE 16