MAINTENANCE
PAGE 32
The appliance is required to be inspected at least once a year by a professional service person.
The compartments on sides of firebox must be cleaned at least once a year, more frequent cleaning may be required due to excessive lint from
carpeting, bedding materials, or other fibrous materials. It is imperative that the burner be cleaned once a year
.
NOTE: INSTALLATION AND REPAIR SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE
INSPECTED BEFORE USE AND ANNUALLY BY A QUALIFIED SERVICE PERSON. MORE FREQUENT CLEANING MAY BE
REQUIRED DUE TO EXCESSIVE LINT FROM CARPETING, BEDDING MATERIALS, ETC. IT IS IMPERATIVE THAT CONTROL
COMPARTMENTS, BURNERS AND CIRCULATION AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN
.
Annual cleaning of burner system is required.
Visually check for blocked port holes, especially near the pilot. Blocked port holes may cause delayed ignition.
Visually check pilot light and burner when in operation. The flames should be steady, not lifting or floating.
Burner Ports
Annual examination of the venting system by a qualified agency is required.
IF VENT-AIR INTAKE SYSTEM IS DISASSEMBLED FOR ANY REASON, RE-INSTALL PER INSTRUCTIONS PROVIDED WITH INITIAL
INSTALLATION.
The flow of combustion and ventilation air must not be obstructed.
VENT SYSTEM
FAN
IMPORTANT: ANY SAFETY SCREEN OR GUARD REMOVED FOR SERVICING MUST BE REPLACED PRIOR TO OPERATING THE APPLIANCE.
Burner Orifice
Clean glass only when cool and only with non-abrasive cleansers.
Do not operate this fireplace with glass/frame assembly removed, cracked or broken.
The glass assembly, part #JXL-057T, shall only be replaced as a complete unit, as supplied by Hussong Mfg. Co., Inc.
Replacement of glass & frame assembly, part #JXL-057T, must only be performed by a licensed or qualified service person.
DO NOT SUBSTITUTE MATERIALS.
Do not strike or slam glass door assembly.
CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND
DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING.
CAUTION: KEEP APPLIANCE AREA CLEAR OF COMBUSTIBLE MATERIALS, SUCH AS GASOLINE AND OTHER FLAMMABLE VAPORS AND LIQUIDS.
GLASS CLEANING & REPLACEMENT
CONTROL BOARD SYSTEM
The fan should be disconnected from electrical current, and cleaned (vacuumed) every six months. The bearings are sealed and require no oiling.
Pilot
Figure 32a