EXISTING FIREPLACE SPECIFICATIONS
THIS INSERT IS APPROVED FOR INSTALLATION IN MASONRY AND FACTORY-BUILT SOLID FUEL BURNING FIREPLACES.
EXISTING FIREPLACE REQUIREMENTS
The existing fireplace & chimney must be clean and in good working order and constructed of non-combustible materials.
A gas line must be able to be installed to the insert.
Provisions made to provide electrical power for operation.
Any chimney clean-outs must fit properly.
Existing Chimney must be comprised of one of the following: Factory built solid fuel chimney: 7” minimum inside diameter.
Masonry chimney: 6" x 8" minimum inside diameter.
Existing Chimney Height: Minimum: 10 ft. (3.05m)
Maximum: 35 ft. (10.67m)
1. Remove and discard existing chimney cap.
2. Position one person at fireplace and another person at top of chimney.
Measure from fireplace base to top of chimney.
Subtract 19-
3/4” (501 mm) (height of insert).
This is the total length of co-linear flexible aluminum you will require.
MEASUREMENT FROM FIREPLACE BASE TO TOP OF CHIMNEY:_________________
LESS 19-3/4" (501 mm) (HEIGHT OF INSERT): -19-3/4" (501 mm)
TOTAL CHIMNEY LENGTH REQUIRED:
_________________
NOTE: It is helpful to have two people complete next step to determine chimney
height.
CAUTION: This appliance must not be connected to or joined with any other
chimney flue serving another appliance.
PAGE 9
DETERMINE LENGTH OF EXISTING CHIMNEY
Figure 9a
MIN. 10 ft. (3.05 m)
MAX. 35 ft. (10.67m)
Summary of Contents for Minneapolis MPS-30
Page 37: ...PAGE 36 LIMITED WARRANTY...
Page 38: ...PAGE 37 LIFETIME WARRANTY...