62
ELECTRICAL INFORMATION
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#CLW-ST R.1 February 2021
9.4 #CWST-028 Optional Fan Kit
ATTENTION: Installation of this fan kit should be done only by a
qualified installer.
WARNING: Verify household breaker is shut off prior to working on
any electrical lines. Disconnect all electric power from fireplace before
performing any of these tasks.
If you wish to install a block-off plate to divert air into a certain room,
see Section 9.4.1 Fan Channel Block-off Plate on page 63 for more
information.
1. Remove safety barrier screen, access cover, and front glass frame
assembly.
2. Disconnect wiring terminals from fan motors.
3. The fan will be installed on the side opposite of the exhaust.
4. With the terminal end of the fan facing you and the fan terminals
on the left, insert fan into chamber. See Figure 9.4.
5. When the terminal end clears the fireplace face, rotate the fan
counter-clockwise.
6. Insert the fan down and forward into control compartment, as
shown below.
7. Place the upper edge of the fan discharge under the edge of
fireplace air channel opening. Rotate the fan up towards the
edge to secure fan into place. See Figure 9.4. DO NOT LET THE
FAN REST ON ANY ELECTRICAL CORDS.
8. Reattach wiring terminals to fan motors.
9. Plug the fan cord into the receptacle on the IFC control module.
10. Reinstall the front glass frame assembly, access cover and safety
barrier screen.
Figure 9.4, #CWST-028 Fan Installation