#BAY-41-G R.9 Sept 2018
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
VENTING
25
7.0 VENTING
7.1.2 Remove Back Vent Combustion
Air Intake and Exhaust Collars
7.1 Rear Vent Conversion Instructions
IMPORTANT: This appliance has outlets for both top and rear venting.
The unused vent exit must have the cover plates in place, and the cover
plates must be removed from the exit according to the instructions
below to be used.
NOTE: All components removed from the top vent exit will be reinstalled
for the rear vent.
7.1.1 Remove Top Vent Collars
1) REMOVE THE ATTACHMENT SCREW SECURING COVER
2) REMOVE (4) SCREWS SECURING 6-5/8” (168mm) COMBUSTION AIR INTAKE COLLAR
3) REMOVE (6) SCREWS SECURING 4” (101mm) EXHAUST COLLAR
1) REMOVE THE ATTACHMENT SCREW SECURING BACK COVER PLATE
2) REMOVE (4) SCREWS SECURING COMBUSTION AIR INTAKE REAR COVER PLATE
3) REMOVE (6) SCREWS SECURING EXHAUST COVER REAR PLATE