![kozy heat BAY-36-L Installation And Operation Manual Download Page 12](http://html1.mh-extra.com/html/kozy-heat/bay-36-l/bay-36-l_installation-and-operation-manual_1999705012.webp)
12
FRAMING
3.3 Clearances to Combustibles
Table 3.1, Minimum Appliance Clearances to Combustible Material
From appliance top stand-offs
0 in
0 mm
From appliance left and right side stand-offs
0 in
0 mm
From appliance back stand-offs
0 in
0 mm
From appliance corners
1/4 in
6 mm
From appliance front
36 in
914 mm
From appliance top to ceiling
30 in
762 mm
Appliance sides to adjacent sidewall
3/4 in
19 mm
Mantel 9 in (229 mm) deep from appliance top
13-1/2 in
343 mm
Figure 3.2, Typical Install Options
1”
(25mm)
36
¼
”
(920mm)
1”
(25mm)
15
7⁄8
”
(403mm)*
1”
(25mm)
26
½
”
(673mm)**
1”
(25mm)
50
7⁄16
”
(1280mm)
36
¼
”
(920mm)
11
7⁄8
”
(301mm)
¼
”
(6mm)
24
11⁄16
”
(628mm)
35
5⁄8
”
(905mm)
36
¼
”
(920mm)
15
7⁄8
”
(403mm)*
36
¼
”
(920mm)
15
7⁄8
”
(403mm)*
36
¼
”
(920mm)
*INCLUDES ½” TYPICAL FINISH MATERIAL WITH FLUSH MOUNT
**DIMENSION SHOWN WITH LISTED DURAVENT ELBOW.
NOTE: Approved vent system elbows for this appliance vary in
vertical length. Consult vent manufacturer’s instructions to
determine the elbow dimension used for your installation.
Adjust as necessary to maintain the required 1” (25mm)
clearance from the vent pipe to combustible material.
TYPICAL VERTICAL INSTALLATION
TOP VENT
TYPICAL HORIZONTAL INSTALLATION
TOP VENT
TYPICAL CORNER INSTALLATION
TOP VENT
TYPICAL HORIZONTAL INSTALLATION
REAR VENT
TYPICAL VERTICAL INSTALLATION
REAR VENT