Gas Requirements 
 

This unit has been certified for use with both Natural Gas (NG) or Liquid Propane (LP).  The 
following is a chart for the minimum and maximum supply pressures. 
 

Gas 

Minimum Supply 

Pressure 

Normal Supply 

Pressure 

Maximum Supply 

Pressure 

Natural Gas 

(NG) 

5.0" W.C 

7.0" W.C. 

8.0" W.C 

Propane (LP) 

10.5" W.C. 

11.5" W.C. 

13.0" W.C. 

 
The gas valve has it’s own internal regulator which reduces the pressure within the following 
ranges:  0.9 to 3.5” W.C. for natural gas and 2.5 to 10.0” W.C. for propane. 
 
The gas connection provided with this unit is a flexible connector and is easily accessible 
through the rear, side and bottom of the stove or by opening the side door panel and reaching in 
through the access hole.  The gas line can also be rigid pipe, if so desired.  To make the 
installation easier, use the flexible connector and manual shutoff valves necessary, according to 
the local building codes.   
 
Pressure taps are provided for checking the inlet and outlet gas pressure.  The taps are located 
on the front of the valve body.   
 
The appliance and it’s appliance main gas valve must be disconnected from the gas supply 
piping system during any pressure testing of that system at test pressures in excess of ½ psi 
(3.5 kPa).   
 
The appliance must be isolated from the gas supply piping system by closing its equipment 
shutoff valve during any pressure testing of the gas supply piping system at test pressures 
equal to or less than ½ psi (3.5 kPa).  

Venting Requirements 

 

 

This stove has been tested and certified with the following venting kits and their components.  
Only the parts listed below can be used for the installation of this appliance. 

 

Venting Kit #DV1-MVK1 – 

venting installations under 15 ft. vertical rise 

Venting Kit #DV1-MVK2

 – venting installations over 15 ft. and under 30 ft. vertical rise. 

 

Each of the above kits contains the following components: 
 

One Vent Terminal Cap 

 

 

 

 

 

One Terminal Adapter Box 
Two 3” diameter 2 ply Aluminum flex pipes of suitable length 
Four 3” Stainless Steel adjustable hose clamps, and sheet metal screws 
High temperature sealant 

 

Installers may be required to provide a Chimney Cover Plate for certain installations. 
 
Venting terminals shall not be recessed into a wall or siding.   
 

 

 

Summary of Contents for DV1-M1

Page 1: ...d liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS o Do not try to light any appliance o Do not touch electrical switches do not use the phone in your building o Imme...

Page 2: ...fety Certification Information 6 Installation 7 Firebox Preparation 7 Venting Installation 7 Insert Installation 8 Your First Fire 9 Log Installation 10 Surround Assembly 11 Operating Instructions 12...

Page 3: ...g a separate solid fuel burning appliance Never vent into another room or inside a building 6 This insert is Direct Vented The fresh combustion air required by this gas stove is drawn from outside the...

Page 4: ...ocated on the front of the valve body The appliance and it s appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure...

Page 5: ...im the excess later Fireplace Requirements and Clearances to Combustibles Description Width Height Depth Minimum Fireplace Opening 22 20 5 16 Maximum Opening With Surround 1 39 29 Maximum Opening With...

Page 6: ...panel that can be pulled out from the control compartment Note Due to constant development KOZI units and technologies are consistently being upgraded Please ensure that the label contained on this pa...

Page 7: ...ation The extra cleaning required before you install the insert into the firebox is essential because of the circulation fan mounted inside the unit This fan will pick up the odor from the creosote as...

Page 8: ...e chimney opening until the bottom plate of the adapter box rests on top of the chimney cover plate Fasten the adapter box to the chimney Figure 2 Assembly diagram of venting components Insert Install...

Page 9: ...Never Be Attached To A Chimney Serving A Separate Solid Fuel Or Gas Burning Appliance Figure 4 Diagram showing proper and improper installations Your First Fire This section of the manual has been inc...

Page 10: ...arge odors You may have to repeat this process several times Log Installation 1 Turn the burner switch to OFF Turn the gas valve OFF Allow the unit time to cool 2 Remove the side panels of the stove b...

Page 11: ...of the correctly positioned logset Surround Assembly 1 Assemble the surround as shown in the diagram provided below Make sure to fasten the nut to the bolt securely 1 Attach the brass trim to the surr...

Page 12: ...r Near The Appliance Any And All Equipment Removed From This Unit For Maintenance Or Servicing Must Be Reinstalled Prior To Further Operation Of This Unit Under No Circumstances Should This Unit Be Mo...

Page 13: ...t or flame height 8 Close the control compartment door while operating the unit Shutdown Instructions 1 Open the control compartment door 2 Turn the burner switch to the OFF position This will turn of...

Page 14: ...The Manufacturer Of Your Local KOZI Dealer The Use Of Substitute Parts Can Alter The Performance Characteristics Of This Unit And Could Cause Serious Health And Safety Conditions To Arise CAUTION Any...

Page 15: ...lean the unit when hot Inspect the door gasket regularly and if it requires replacing use fibre glass braided rope APR DV1 605 Log Replacement If replacement logs are required you must use only the pr...

Page 16: ...counted for continue with the following instructions 1 Turn the main burner switch OFF turn the gas control knob to the OFF position and allow time for the unit to cool Turn OFF or disconnect the gas...

Page 17: ...hten the screws securely Tighten the new orifice completely Figure 7 Schematic illustration of the Pilot Assembly and components 8 Adjust the primary air setting on the burner assembly by loosening an...

Page 18: ...lt Diagrams Shown below are the wiring schematics for the blower and gas valve assemblies CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and da...

Page 19: ...03 Trim Moulding Side DV1 MI 104 Trim Moulding Top DV1 105 KOZI Logo 2 DV1 2 Burner Body Assembly 3 DV1 3 Control Door Assembly DV1 301 Door Handle 4 DV1 4 Hearth 5 DV1 5 Door Support 6 DV1 6 Glass Do...

Page 20: ...xplosion Gate Assembly DV1 2003 Explosion Gate Gasket 21 DV1 21 Explosion Gate Bracket 22 DV1 22 Mounting Plate Assembly DV1 2202 Gas Valve Mounting Bracket DV1 2203 Gas Orifice Mounting Bracket DV1 2...

Page 21: ...d in accordance with the applicable rating plate Discoloration and expansion movement of certain parts is normal and will not be covered under warranty Gas Valve and Electrical Components Gas and elec...

Reviews: