background image

Warranty terms and scope

KOTA Equipamentos guarantees the product and its accessories for 

defects in materials and workmanship; always they have been used in 

accordance with the conditions of use specified in the User’s Manual.

The warranty period is one year from the date of the purchase invoice, 

being 3 (three) months of legal guarantee and 9 (nine) months of 

contractual guarantee.

The replaced parts or accessories will be guaranteed for a period of 90 

(ninety) days from the date of return of the appliance to the customer or for 

the remaining time of the original warranty, whichever is the last.

Warranty: ItEMS ExCLuDED

This warranty does not cover:

•  Damage resulting from the use of the product in a manner other than

  that specified in the user’s manual.

•  Defects caused by installations, alterations, tests or any type of

  modifications by people or technical services not authorized by KOTA

 Equipamentos.

•  Products with the serial number removed or illegible.

•  Damages caused by spillage of aggressive substances on the product.

•  Electrical discharges or variations of electrical current that may damage

  the equipment.

In case of be necessary to contact KOTA Equipamentos, have the purchase 

invoice of the equipment and the respective serial number.

15

Summary of Contents for Furnace PRO

Page 1: ...USER Manual Furnace PRO ...

Page 2: ... be compromised Any alteration of the product without previous authorization will imply the loss of the guarantee Do not use extensions or any type of connector between the power cord of the appliance and the socket Procedures such as these could decrease the performance of your equipment and increase your energy consumption For cleaning use only a damp cloth Do not apply abrasive solvent or corro...

Page 3: ...Index Features 4 Technical data 4 Equipment overview 4 Initial set up 5 Language selection 6 Selecting editing firing programs 6 Warranty terms and scope 15 ...

Page 4: ...wer supply Check Furnace voltage Maximum consumption 1300 Watts Fuse 20A Maximum current of the vacuum pump intake 10A Maximum operating temperature 1150 C Height 465mm Width 298mm Depth 420mm Net weight 14 1kg Gross weight 16 2kg Frequency 50 60Hz Colour black Features Specifications Equipment Overview Fuse 20A Electrical Connection for the Vacuum Pump Connection for Vacuum hose Power Cable Main ...

Page 5: ...he rubber seal ring could be damaged Aluminium tray Refractory Plate 3º connect the Vacuum Pump power cable to electrical connector located on the back of the unit as shown in the illustration on page 3 Check the main voltage The Vacuum Pump voltage must be the same as that of the oven 4º connect the Vacuum Pump power cable to electrical connector located on the back of the unit as shown in the il...

Page 6: ...r more than 5 minutes the muffle will close To open the muffle press the directional arrow on the left side Selecting and editing a ceramic program When selecting the firing program we will have the following indications on the screen On this screen it is possible to move the lift up down and stop in any position manually Just press the left directional arrow to perform the two functions The firin...

Page 7: ...l temperature is the initial temperature of the firing process DRYINGTIME TSEC The drying time is the waiting period for the start of the closing stage of the muffle RISETIME TSUB The closing time of the muffle can be adjusted to close directly or for a specific time between 00 40 seconds and 30 00 minutes To activate the direct closing adjust the parameters in 00 00 7 ...

Page 8: ...n the muffle will close DOWNINGTIME TDES The downing time is activated after the last firing process be executed and can be adjusted for direct opening or for a determined time between 00 40 seconds and 30 00 minutes To activate the direct opening set the parameters to 00 00 BASETEMPERATURE TP2 It is the next temperature level after the initial temperature 8 ...

Page 9: ...e parameters can be adjusted from 20 to 120 C per minute VACUUM RAMP 2 VR2 Determines if there will be a vacuum between the initial temperature up to the base temperature 2 Use the ON or OFF function to configure the parameter BASETIME TPAT2 Determines the temperature dwell time programmed in base 2 9 ...

Page 10: ...uum time 2 The vacuum time must always be equal to or less than the base time BASETEMPERATURE 3 TP3 Enables or disables the 3rd base If this parameter is disabled the next parameter to be executed is the downing time and then the program completion TEMPERATURE BASE 3 TP3 It is the next temperature level after the base temperature 2 10 ...

Page 11: ... and the base temperature 3 VACUUM RAMP 3 VR3 Determine if there will be a vacuum between the base temperature 2 to the base temperature 3 Use the enable or disable function to configure the parameter BASETIME 3 TPAT3 Determine the dwell time of the base temperature 3 11 ...

Page 12: ...he vacuum time 3 The vacuum time must always be equal to or less than the base time BASETEMPERATURE 4 TP4 Enable or disable the 4 base If that parameter was disabled the next parameter to be executed is the download time and then the program completion BASETEMPERATURE 4 TP4 It is the next temperature level after the base temperature 3 12 ...

Page 13: ...ase temperature 4 VACUUM RAMP 4 VR4 Determine if there will be a vacuum between the base temperature 3 up to the base temperature 4 Use the ON function to enable or OFF to disable for configuration of the parameter BASETIME 4 TPAT4 Determine the dwell time of the base temperature 4 13 ...

Page 14: ...r less than the base time ALTER NAME OFTHE PROGRAM To alter the name of the program press the EDIT key for 2 two seconds until the name of the program appears on the screen The cursor will blink in the first field to be altered To alter the name of the program use the up and down arrows To navigate between the edit fields press the right or left arrow keys To save press the EDIT key 14 ...

Page 15: ...er or for the remaining time of the original warranty whichever is the last Warranty Items excluded This warranty does not cover Damage resulting from the use of the product in a manner other than that specified in the user s manual Defects caused by installations alterations tests or any type of modifications by people or technical services not authorized by Kota Equipamentos Products with the se...

Page 16: ...m br Rua Íris Memberg 140 Vila Jovina Cotia SP I CEP 06705 150 I Brazil 55 11 4615 9200 TECHNICAL CONSULTANT consultoria lab kotaimp com br 55 11 4615 9200 55 11 9 9488 3529 SAC sac kotaimp com br 55 11 4615 9200 55 11 9 6196 2763 ...

Reviews: