5. Main menu
!
!
1
8.
1
.5
S
ervice
Used to confi gure the timer program to control the central heating.
Description of the functions
in the SERVICE submenu
NOTE!!!
The service menu is intended for qualifi ed technical
personnel only. The changes may cause malfunction
of the system.
FUNCTION
DESCRIPTION
Pump MIN temp.
The minimum calculated
temperature of central heating,
at which the circulation pump
can operate.
Source
Determines the energy source
for central heating circuit.
Max. temperature
Maximum calculated
temperature for central
heating.
Mixer time
Time of mixer full opening.
DHW priority
DHW priority for the given
central heating circuit. The
central heating pump is not
operating during domestic
hot water heating.
Pump test
Turns on the circulating pump
regardless of other conditions.
Mixer test
Turns on the mixer actuator
independently of other
conditions.
Circuit name
gives name for the central
heating circuit
CH temp. for -20°C
The point of the heating curve
for 0°C.
CH temp. for 0°C
Punkt krzywej grzewczej
dla 0°C.
CH temp. for 10°C
The point of the heating curve
for 10°C.
FUNCTION
DESCRIPTION
Correction factor
The correction of the central
heating set temperature with
regard to the temperature
set in a room per each 1°C.
For example, if the correction
factor is set to 6°C, the preset
room temperature to 20°C
and the temperature measured
in the room is 20.5°C, then
the calculated central heating
temperature will be reduced
by 3°C.
Operation mode
Determines the mode of
temperature presetting for
central heating manual - the
central heating temperature
is preset manually, weather
controlled - the central heating
temperature is calculated from
the heating curvej
Manually set TCH
Central heating preset
temperature when the
operating mode is set to
manual
Central heating (CH) sensor
Determines whether the
system uses a room sensor
Czujnik CO
Specifi es whether the system
contains a room sensor
Permanent pump
Yes - the pump runs after
reaching the preset temperature
in the room; the calculated
temperature of the central
heating is lowered (only if the
central heating sensor and
room sensor are applied)
No - after reaching the preset
temperature in the room the
pump is turned off
5.1.5
S
ervice